• Title/Summary/Keyword: Nu-A

Search Result 793, Processing Time 0.027 seconds

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Experiments on Natural Convection on the Outer Surface of a Vertical Pipe by Using Fluids with High Pr Number (높은 Pr 수의 유체를 사용한 수직 원형관 외부의 자연대류 실험)

  • Kang, Gyeong-Uk;Chung, Bum-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.33-42
    • /
    • 2011
  • In this study, we investigated the natural convection on the outer surface of a vertical pipe by performing mass transfer experiments using fluids with high Pr number using the concept of analogy between heat and mass transfer. A cupric acid-copper sulfate electroplating system was adopted as the mass transfer system. Tests were performed for $Ra_H$ numbers from $1.4{\times}10^9$ to $4{\times}10^{13}$, Pr numbers from 2,094 to 4,173, and diameters from 0.005 m to 0.035 m. The test results for laminar flow conditions were in good agreement with the correlations reported by King, Jakob and Linke, McAdam, and Bottemanne, and those for turbulent conditions with the correlations presented by Fouad for a vertical plate and also proved the dependence on Pr numbers. The obtained correlations were $Nu_H=0.55Ra^{0.25}_H$ for laminar and $Nu_H=0.12Ra^{0.28}_HPr^{0.1}$ for turbulent. The transition between laminar and turbulent occurs at $Ra_H$ of about $10^{12}$.

Affinity for 57Co-Vitamin B12 by a Wide Histologic Variety of Tumor Types in Mice (생쥐 종양모델에서 57Co-Vitamin B12의 종양 친화성에 관한 연구)

  • Sohn, Myung-Hee;Park, Soon-A;Kim, Su-Hyun;Chung, Gyung-Ho;Yim, Chang-Yeol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.89-98
    • /
    • 1998
  • The search for tumor-avid agents for use in nuclear medicine imaging is an ongoing field of importance. The purpose of this study was to determine the affinity for radio labeled vitamin $B_{12}$ by a wide histologic variety of tumor types in mice. Seventeen different types of tumor were grown subcutaneously in female Balb/C or Balb nu/nu(nude) mice. When the tumors reached about 1 cm in diameter, mice were injected intraperitoneally with $^{57}Co$-vitamin $B_{12}$. Twenty-four hours later, the mice were sacrificed. Organs and tissues were removed, weighed, and activity per mg determined by gamma counter. Values represented cpm/mg tissue that was normalized to 20 grams body weight for each mouse. A wide variety of tumor types showed significant uptake and concentration of $^{57}Co$-vitamin $B_{12}$, as evidenced by tumor:tissue activity ratios. For many tissues of great importance in terms of background(bone, muscle, blood), the tumor:tissue activity ratios of uptake were high. These data strongly suggest that further efforts to evaluate the utility of radio labeled adducts of vitamin $B_{12}$ for clinical use in oncologic imaging are warranted.

  • PDF

Optical and Dielectric Properties of Chalcogenide Glasses at Terahertz Frequencies

  • Kang, Seung-Beom;Kwak, Min-Hwan;Park, Bong-Je;Kim, Sung-Il;Ryu, Han-Cheol;Chung, Dong-Chul;Jeong, Se-Young;Kang, Dae-Won;Choi, Sang-Kuk;Paek, Mun-Cheol;Cha, Eun-Jong;Kang, Kwang-Yong
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.667-674
    • /
    • 2009
  • Terahertz time-domain spectroscopy has been used to study the optical and dielectric properties of three chalcogenide glasses: $Ge_{30}As_8Ga_2Se_{60}$, $Ge_{35}Ga_5Se_{60}$, and $Ge_{10}As_{20}S_{70}$. The absorption coefficients ${\alpha}({\nu})$, complex refractive index n(${\nu}$), and complex dielectric constants ${\varepsilon}({\nu})$ were measured in a frequency range from 0.3 THz to 1.5 THz. The measured real refractive indices were fitted using a Sellmeier equation. The results show that the Sellmeier equation fits well with the data throughout the frequency range and imply that the phonon modes of glasses vary with the glass compositions. The theory of far-infrared absorption in amorphous materials is used to analyze the results and to understand the differences in THz absorption among the sample glasses.

Internal Energy Distributions of OH Products in the Reaction of O(3PJ) with HSiCl3

  • Kwak, Hyon-Tae;Ha, Seung-Chul;Jang, Sung-Woo;Kim, Hong-Lae;Park, Chan-Ryang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.429-434
    • /
    • 2009
  • The OH($X^2{\Pi},\;{\nu}$"=0, 1) internal state distributions from the reaction of electronically ground state oxygen atoms with HSi$Cl_3$ were measured using laser-induced fluorescence. The ground-state O$(^3P_J)$ atoms with kinetic energies above the reaction barrier were produced by photolysis of N$O_2$ at 355 nm. The OH product revealed strong vibrational population inversion, P(${\nu}$"=1)/P(${\nu}$"=0) = 4.0 ${\pm}$ 0.6, and rotational distributions in both vibrational states exhibit substantial rotational excitations to the limit of total available energy. However, no preferential populations in either of the two $\Lambda$ doublet states were observed from the micropopulations, which supports a mechanism involving a direct abstraction of hydrogen by the atomic oxygen. It was also found that the collision energy between O and HSi$Cl_3$ is effectively coupled into the excitation of the internal degrees of freedom of the OH product ($$ = 0.62, and $<\;f_{rot}>$ = 0.20). The dynamics appear consistent with expectations for the kinematically constrained reaction which supports the reaction type, heavy + light-heavy $\rightarrow$ heavy-light + heavy (H + LH′ $\rightarrow$ HL + H′). The dynamics of oxygen atom collision with HSi$Cl_3$ are discussed in comparison to those with Si$H_4$.

Two More Radicals for Right Near-Rings: The Right Jacobson Radicals of Type-1 and 2

  • Rao, Ravi Srinivasa;Prasad, K. Siva
    • Kyungpook Mathematical Journal
    • /
    • v.46 no.4
    • /
    • pp.603-613
    • /
    • 2006
  • Near-rings considered are right near-rings and R is a near-ring. $J_0^r(R)$, the right Jacobson radical of R of type-0, was introduced and studied by the present authors. In this paper $J_1^r(R)$ and $J_2^r(R)$, the right Jacobson radicals of R of type-1 and type-2 are introduced. It is proved that both $J_1^r$ and $J_2^r$ are radicals for near-rings and $J_0^r(R){\subseteq}J_1^r(R){\subseteq}J_2^r(R)$. Unlike the left Jacobson radical classes, the right Jacobson radical class of type-2 contains $M_0(G)$ for many of the finite groups G. Depending on the structure of G, $M_0(G)$ belongs to different right Jacobson radical classes of near-rings. Also unlike left Jacobson-type radicals, the constant part of R is contained in every right 1-modular (2-modular) right ideal of R. For any family of near-rings $R_i$, $i{\in}I$, $J_{\nu}^r({\oplus}_{i{\in}I}R_i)={\oplus}_{i{\in}I}J_{\nu}^r(R_i)$, ${\nu}{\in}\{1,2\}$. Moreover, under certain conditions, for an invariant subnear-ring S of a d.g. near-ring R it is shown that $J_2^r(S)=S{\cap}J_2^r(R)$.

  • PDF

A Morphometric Study of Primary Anterior Zirconia Crowns in Korean Tooth Models (한국 유치 모델에서 유전치 지르코니아 크라운의 형태계측학적 연구)

  • Park, Jungha;Lee, Sangho;Lee, Nanyoung;Jih, Myoungkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-56
    • /
    • 2018
  • The purpose of this study was to provide clinical recommendations for restoration with selection of the most similar zirconia crown by 3-dimensional analysis of the shape of the maxillary primary central and lateral incisors in Korean individuals and prefabricated zirconia crowns. The average shape of the sound maxillary primary central and lateral incisors in 300 children was reproduced by 3-dimensional scanning. Zirconia crowns of 4 manufacturers (NuSmile $ZR^{(R)}$ Crown, Cheng $Crowns^{(R)}$, Kinder $Krowns^{(R)}$, and EZ $Pedo^{(R)}$ Crown) were scanned 3-dimensionally, and coordinates for comparison of the shape were measured to evaluate the similarity between the teeth and crowns. The most similar crowns were selected by comparing the mesiodistal length, crown height, crown shape ratio, distance between the same coordinates of a tooth and crown, the radius of curvature of the labial surface, and the volume. As a result of analysis, Cheng $Crowns^{(R)}$ size 3 and NuSmile $ZR^{(R)}$ Crown size 2 were the most similar crowns in the maxillary primary central and lateral incisors, respectively. Scanning the inner surface of the crowns and evaluating the amount of tooth reduction required suggested that an overall lesser amount of tooth reduction compared to that presented by the manufacturer's guidelines should be performed.

A Study of the Retention Mechanism of the Monosubstituted Benzenes in Reversed-phase Liquid Chromatography (II) (역상 액체크로마토그래피에서 벤젠 일치환체들의 머무름 메카니즘에 관한 연구 (제 2 보))

  • Lee, Dai-Woon;Choi, Yong-Wook;Lee, Won
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.135-143
    • /
    • 1988
  • The correlations between chromatographic parameters of monosubstituted benzenes and several physical parameters in reversed phase liquid chromatography were studied. The relationships between retention data and polarity index were investigated by plotting $log(log k'_S/k'_B)$ vs. $P'_S/P'_B$ which were relative retention and relative polarity index of monosubstituted benzenes with respect to benzene, respectively. The linear relationship between relative retention and polarity index was observed for the monosubstituted benzenes having polar group, while in case of those having nonpolar group, the good linearity was observed by combination with relative molecular weight i.e. $(P'_S/P'_B)/(MW_S/MW_B)$. Multivariant regression analysis, $a(P'_S/P'_B)+b(MW_S/MW_B)$+c did not give significantly better correlations compared to single variant analysis, $a[(P'_S/P'_B)/(MW_S/MW_B)]$+c, but multiple stepwise regression analysis was recommended when several physical parameters simultaneously were chosen. The best correlation between retention data for monosubstituted benzenes taken from the literature and substituent constant(${\pi}$), derived from hydrophobic parameter and the first order molecular connectivity index$(^1{\chi}^{\nu})$, was established for methanol/water mobile phase system. The larger the surface coverage of the stationary phase, the higher was the correlation coefficient between these two parameters and retention data.

  • PDF

Inversion of Rayleigh-wave Dispersion Curves for Near-surface Shear-wave Velocities in Chuncheon Area (춘천지역의 천부 횡파속도를 구하기 위한 레일리파 분산곡선 역산)

  • Kim, Ki-Young;Kim, Woo-Jung;Park, Yeong-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • To evaluate methods of determining near-surface shear-wave velocities (${\nu}_s$), we derived dispersion curves of Rayleigh waves generated by both passive and active sources in Chuncheon, Korea. Microtremors were recorded for 5 minutes in each of four triangular arrays with radii of 5 ~ 40 m. Those data were analyzed using the Spatial Autocorrelation method. Rayleigh waves were also generated by a hammer source and recorded in the same area for 2 s using 24 4.5-Hz geophones. Multichannel Analysis of Surface Waves was applied to those data. Velocity spectra were derived with relatively high signal-to-noise ratios in the frequency ranges of 7 ~ 19 and 11 ~ 50 Hz for the microtremors and synthetically generated Rayleigh waves, respectively. The resultant dispersion curves were combined as one and then input to inversion to derive shear wave velocities that were compared with a lithology log from a nearby well. Shearwave velocities in the top soil and soft-rock layers are almost constant with values of 221 and 846 m/s, respectively; while the inverse-modeled ${\nu}_s$ increases linearly in the gravelly sand, cobbles, and weathered-rock layers. If rock type is classified based on shear-wave velocity, the inversion-derived boundary between weathered-rock and soft rock may be about 5 m deeper than in the well log.

Abstraction of Models with State Projections In Model Checking (모델 체킹에서 상태 투영을 이용한 모델의 추상화)

  • Kwon, Gi-Hwon
    • The KIPS Transactions:PartD
    • /
    • v.11D no.6
    • /
    • pp.1295-1300
    • /
    • 2004
  • Although model checking has gained its popularity as one of the most effective approaches to the formal verification, it has to deal with the state explosion problem to be widely used in industry. In order to mitigate the problem, this paper proposes an ion technique to obtain a reduced model M' from a given original model M. Our technique Identifies the set of necessary variables for model checking and projects the state space onto them. The model M' is smaller in both size and behavior than the original model M, written M'$\leq$M. Since the result of reachability analysis with M' is preserved in M, we can do reachability analysis with model checking using M' instead of M. The abstraction technique is applied to Push Push games, and two model checkers - Cadence SMV and NuSMV - are used to solve the games. As a result, most of unsolved games with the usual model checking are solved with the ion technique. In addition, ion shows that there is much of time and space improvement. With Cadence SMV, there is 87% time improvement and 79% space one. And there is 83% time improvement and 56% space one with NuSMV.