• Title/Summary/Keyword: Noxious Gases

Search Result 44, Processing Time 0.031 seconds

Strategies for reducing noxious gas emissions in pig production: a comprehensive review on the role of feed additives

  • Md Mortuza Hossain;Sung Bo Cho;In Ho Kim
    • Journal of Animal Science and Technology
    • /
    • v.66 no.2
    • /
    • pp.237-250
    • /
    • 2024
  • The emission of noxious gases is a significant problem in pig production, as it can lead to poor production, welfare concerns, and environmental pollution. The noxious gases are the gasses emitted from the pig manure that contribute to air pollution. The increased concentration of various harmful gasses can pose health risks to both animals and humans. The major gases produced in the pig farm include methane, hydrogen sulfide, carbon dioxide, ammonia, sulfur dioxide and volatile fatty acids, which are mainly derived from the fermentation of undigested or poorly digested nutrients. Nowadays research has focused on more holistic approaches to obtain a healthy farm environment that helps animal production. The use of probiotics, prebiotics, dietary enzymes, and medicinal plants in animal diets has been explored as a means of reducing harmful gas emissions. This review paper focuses on the harmful gas emissions from pig farm, the mechanisms of gas production, and strategies for reducing these emissions. Additionally, various methods for reducing gas in pigs, including probiotic interventions; prebiotic interventions, dietary enzymes supplementation, and use of medicinal plants and organic acids are discussed. Overall, this paper provides a comprehensive review of the current state of knowledge on reducing noxious gas in pigs and offers valuable insights for pig producers, nutritionists, and researchers working in this area.

A Study on Noxious Gases Analysis of Polyurethane foams (Polyurethane foam의 유해가스 분석에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.7-13
    • /
    • 2000
  • We had investigated thermal stability, Ignition temperature and fire gas for polyurethane foams used for manikin, cushion and interior finishing material. Decomposition of polyurethane foams with temperature was investigated using a DSC and the weight loss with temperature increase using a TGA in order to find the thermal hazard of polyurethane foams, and the ignition temperature of polyurethane foams according to species. We studied constant temperature among ignition temperature measuring methods. In addition, noxious gases for polyurethane foams according to combustion condition were analyzed using gas analyzer and GASTEC. As results, initial decomposition temperature of polyurethane foam used for interior finishing material was lower than those for manikin and cushion, and exothermic energy was higher. Ignition temperature of polyurethane foam of interior finishing material was $420^{\circ}$. All of combustion forms at $427^{\circ}$ and under were smoldering combustion, and it was combustion at $500^{\circ}$. As furnace temperature was increased, concentration of noxious gases such as carbon oxide, carbon dioxide, and hydrogen cyanide was increased. And nitrogen oxide at combustion condition($500^{\circ}$) was over 10 ppm.

  • PDF

Identification of Gas Mixture with the MEMS Sensor Arrays by a Pattern Recognition

  • Bum-Joon Kim;Jung-Sik Kim
    • Korean Journal of Materials Research
    • /
    • v.34 no.5
    • /
    • pp.235-241
    • /
    • 2024
  • Gas identification techniques using pattern recognition methods were developed from four micro-electronic gas sensors for noxious gas mixture analysis. The target gases for the air quality monitoring inside vehicles were two exhaust gases, carbon monoxide (CO) and nitrogen oxides (NOx), and two odor gases, ammonia (NH3) and formaldehyde (HCHO). Four MEMS gas sensors with sensing materials of Pd-SnO2 for CO, In2O3 for NOX, Ru-WO3 for NH3, and hybridized SnO2-ZnO material for HCHO were fabricated. In six binary mixed gas systems with oxidizing and reducing gases, the gas sensing behaviors and the sensor responses of these methods were examined for the discrimination of gas species. The gas sensitivity data was extracted and their patterns were determined using principal component analysis (PCA) techniques. The PCA plot results showed good separation among the mixed gas systems, suggesting that the gas mixture tests for noxious gases and their mixtures could be well classified and discriminated changes.

The study of quantitative analysis for noxious gases of plastic materials by remote sensing open path FT-IR spectrometer (원격 측정용 개방 경로형 FT-IR spectrometer를 사용하여 플라스틱 재료의 유해 가스 정량 분석에 관한 연구)

  • Cho, Nam-Wook;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.230-235
    • /
    • 2012
  • It is to use many plastic materials as living essential goods. But when the fire is happened, owing to noxious gases, many men should be injured. Therefore as the noxious gases are measured by open path FT-IR spectrometer as remote monitoring, the demage of men could be minimized. Such this system consists of a Fourier transform spectrometer and infrared lamp fitted to long length. The study was to do the quantitative analysis on CO, $NO_2$, HCl, HF gas by remote monitoring open path FT-IR spectrometer. And the method of it should use MLR (multiple linearity regression) method. As result, It was confirmed to be more than 0.95 as $R^2$ of MLR. And then Urethane and PVC of plastic materials selected was burned, the concentration of polluted gases were measured by remote monitoring method.

Heating Value and Noxious Gases Generation of Sandwich Panel Core using Artifical Lightweight Aggregate (다공성 경량골재를 충전재로 활용한 샌드위치 패널 심재의 발열량 및 유해가스 배출특성)

  • 노정식;도정윤;문경주;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.261-266
    • /
    • 2003
  • This study is to investigate the heating value and noxious gases generation such as CO, NO and $SO_2$ known as dangerous gas for human from specimen made of cement and lightweight aggregate. The most quanity of CO gas is generated in EPS(Expanded Poly Styrene), core of commercial sandwich panel. Although specimens mainly composed of cement discharged the relatively less CO gas than organic core such as EPS, specimens which SBR was added discharged the very much amount of CO gas similar to EPS and especially, specimens including foaming agent, gas foaming agent or redipersible powder of VA/VeoVa showed the good properties in the generation of CO gas. From the standpoint of the generation of NO and $SO_2$ gas, both the core of commercial sandwich panel such as EPS, Glass wool and specimens made with polymer dispersion such as St/BA and SBR discharge the very much amount of NO and $SO_2$ gas in comparison of the other specimens. From this study, it was confirmed that organic materials such as core of commercial sandwich panel dischared much more noxious gas than specimens composed of cement and inorganic lightweight aggregate.

  • PDF

Assessing Greenhouse and Noxious Gas Emissions from Stevedoring Work at the Port of Incheon (인천항 육상하역 작업에 따른 온실가스 및 유해가스 발생 추정)

  • Roh, Younghoon;Chang, Young-Tae
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.4
    • /
    • pp.133-150
    • /
    • 2015
  • This study estimates greenhouse and noxious gas emissions caused by cargo-handling equipment at the Port of Incheon in 2013 by applying the NONROAD Model (U.S. EPA). The port emitted 838.4 tons of NOx and 82,747 tons of CO2. The estimates are 2.4 times higher for NOx and 1.3 times higher for CO2 than those of the Port of Los Angeles. Emissions from general cargo-handling equipment are five times more than those from container cargo-handling equipment. Among the three ports comprising the Port of Incheon, the emissions at the North Port, which handles raw materials for industry are relatively higher than those at the other ports. Compared to the study conducted by Chang et al. (2013, 2014), this study finds that CO2 and NOx emissions per cargo-handling equipment are 10 times higher than the corresponding amounts per ship.

Iginition energy effects and noxious product gases of combustible premixed gas in closed space (밀폐공간내의 가연성가스의 점화외 유독성 가스 발생에 대한 연구)

  • 김한석;오규형;최연석;문정기
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.3
    • /
    • pp.35-42
    • /
    • 1992
  • Ignition energy effects of concentration of mixed gas In closed cylindrical vessel(1, 832㎤) are studied. The ignition energy ranged from 25 Joule to 110 Joule, and hidrogen and methane gases were used for flammable gas at stoichiometric condition with oxygen gas and nitrogen gas (N2) was for inert gas, which concentration was maximum 60% . The explosion pressure, temperature, concentration of product gases were calculated. It is found that - The explosion pressure and explosion velocity increase with ignition energy. - The gradience of explosion velocity with ignition energy is steeper than explosion pressure. - The results of calculation are similiar with results of experiment. - NOx is not serious product gas for methane and hydrogen gas, but CO is serious at certain concentration for methane in asphyxiation.

  • PDF

Analysis of Changing Pattern of Noxious Gas Levels with Malodorous Substance Concentrations in Individual Stage of Pig Pens for 24 hrs to Improve Piggery Environment (돈사환경 개선을 위한 생육단계별 돈사내 악취물질 농도 및 유해가스의 1일 변화추세 분석)

  • You, Won-Gyun;Kim, Cho-Long;Lee, Myung-Gyu;Kim, Dong-Kyun
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • Noxious gases with malodorous substance concentrations in each stages of pig buildings were determined at a typical 400sow-scale farm to improve piggery environment. Using IAQ-300 and pDR-1000AN, continuous records for the concentration of $NH_3$, CO, $CO_2$, $NO_2$, $SO_2$, $H_2S$, $O_2$, and along with temperature, humidity, dust concentrates from individual pig pens were collected to analyze every 6 hours' condition of indoor environment for 24 hours' period. In most pig houses, the air quality at noon was good, while at night (00:00~06:00), air composition became noxious in all buildings. The order of buildings' air quality for 24 hrs was pregnant > farrowing > nursery > growing > finishing. The cause of air quality differences was presumed to be the differences of stocking density, defecating amount and the length of exposure time of slurry in indoors. In conclusion, well-designed building structure, proper control of stocking density, quick removal of excreta from pig pens and continuous ventilation are prerequisites to improve pig housing environment.

Effects of NOx and SOx on the Medium pH and microalgal growth in photo-culture system (광배양 시스템에서 NOx 및 SOx의 배지 pH와 미세조류 생장에 미치는 영향)

  • Yoon, Se Young;Hong, Min Eui;Sim, Sang Jun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.3
    • /
    • pp.255-263
    • /
    • 2013
  • Carbon dioxide reduction technologies using photosynthetic microorganism were suggested to overcome environmental destruction caused by $CO_2$ in flue gases from power plant and other industries. However, there are many toxic constituents in flue gas including CO, NOx, SOx. Continuous and Excessive supply of these noxious gases to cells will leads to inhibition of microalgal growth along with partial cell death. In this study, we tested the noxious effect of SOx and NOx on the pH and microalgal growth under photoautotrophic culture in three microalgae of Neochloris oleoabundans, Chlorella vulgaris and Haematococcus pluvialis. As a result, SOx concentration more than 50 ppm led to the rapid reduction of pH, thereby inhibiting of the growth in Neochloris oleoabundans and Chlorella vulgaris. NOx concentration more the 100 ppm reduced the exponential growth of N. oleoabundans and C. vulgaris. And H. pluvialis exhibited low sensitivity to SOx and NOx. Consequently, the three microalgae of N. oleabundas, C. vulagaris and H. pluvialis showed the normal vegetative growth in 25 ppm of NOx and SOx. Above all, H. pluvialis was useful for the $CO_2$ sequestration of the flue gas including high concentrations of NOx and SOx.