• Title/Summary/Keyword: Normalized parameters

Search Result 455, Processing Time 0.023 seconds

Posture Change Affects Indices of Pupil Size - Korean Males in Their Twenties

  • Lee, Jeung-Chan;Kim, Ji-Eun;Park, Kyung-Mo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • To determine the effect of posture change on autonomic activity and to investigate valid parameters to reflex the autonomic activity from time-series pupil size data, a posture-related experiment was performed with 15 subjects, which involved measuring their electrocardiograms and pupil sizes. The experimental procedure consisted of three-sequence postures-supine, sitting and upright-for 5 minutes each, with rest sessions between postures. The subjects were notified of the entire experimental procedure. The parameters of the subjects' heart rate variability showed significant differences between the postures (heart rate: 63-70-80 beat, normalized low frequency power: 28-50-75, normalized high frequency power: 72-49-25 and ratio: 0.5-1.2-4.4 in supine-sitting-upright position respectively) as did the parameters of their mean pupil sizes (41300-53900-53700 pixels respectively) and the major frequencies (the third trend: 0.23-0.2-0.18 Hz respectively) of their pupil size variability according to changes in their autonomic activities induced by posture change. The experiment thus proved that posture change affects autonomic activity and that such activity can be estimated by the parameters of pupil size as similar as heart rate variability.

Spatiotemporal Gait Parameters That Predict Gait Function Based on Timed Up and Go Test Performance in the Hemiplegic Stroke Patients

  • Kim, Jeong-Soo;Kim, Jeong-Ah;Jeon, Hye-Seon;Yu, Kyung-Hoon
    • Physical Therapy Korea
    • /
    • v.20 no.4
    • /
    • pp.40-46
    • /
    • 2013
  • The purpose of this study was to determine which spatiotemporal gait parameters obtained during hemiplegic walking could be a predictive factor for the Timed Up and Go test (TUG). Two hundreds nine subjects who had suffered a stroke were recruited for this study. They were participated in two assessments; the TUG test and gait analysis. The relationship between the TUG test and spatiotemporal parameters was analyzed using Pearson's correlation coefficients. In addition, to predict the spatiotemporal gait parameters that correlated most with the TUG scores, we used multiple linear regression analyses (stepwise method). The results show that the normalized velocity was strongly correlated with the TUG performance (r=-.72, p<.001). Additionally, single support percentage (SSP), double support percentage (DSP), step time difference (STD), and step length difference (SLD) significantly were correlated with the TUG test. Normalized velocity, STD, DSP of affected side, and SSP of non-affected side explained 53%, 8%, 3%, 2%, of variance in the TUG test respectively. In conclusion, an increase in gait velocity and a decrease in STD would be effective indicators of improvement on the functional mobility in the stroke rehabilitation.

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

Consideration for evaluation patterns of normalized RMR parameters (정규화한 RMR 변수들의 평가 경향에 대한 고찰)

  • Lee, Seong-Min;Lee, Yeon-Hee;Kim, Sun-Myung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.23-35
    • /
    • 2012
  • Due to the convenience, RMR has been widely applied in civil engineering works such as tunnel, slope, and so on. Many researchers have studied to suggest more simple and trustable RMR by modifying its parameters. However, those researches have just focused on looking for easy modified-RMRs by reducing number of parameters using various statistical analyses. Therefore, this research studied questions of modified-RMRs and gaps between RMR and its parameters. Approximately 2,000 parameters of 400 RMRs from various tunnel sites were normalized respectively and compared with one another to study their relations and divergences. The comparison results showed that there were common patterns among RMR and parameters. Data of uniaxial compressive strength and RQD, qualitative parameters, were located in upper side of RMR line. Discontinuity condition and ground water, quantitative oriented parameters, were opposite to them. It means if both qualitative and quantitative parameters can be properly combined then it can be easy to make simple and easy modified-RMRs without using difficult statistics. This results also show that the majority of field engineers used to estimate RMR conservatively when they did quantitative oriented parameters.

Characteristic Analysis of LCC Type High Frequency Resonant Inverter using ZVS (ZVS-LCC형 고주파 공진 인버터의 특성해석)

  • 서철식;김동희;노채균;남승식;변영복;이봉섭
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.311-317
    • /
    • 1999
  • In this paper, the resonant inverter of SEPP-LCC type is proposed and described the operating principle. As adding t two capacitors in the switching devices in parallel. the proposed inverter can reduce switching losses. noise and voltage s stress at Turn-on and Turn-off. The analysis of the proposed circuit are described by using the normalized parameters. The data of design are got by the characteristic values and an example of the design's method is proposed. In addition. t the justification of theoretical analysis is verified by comparing to the experimental waveforms.

  • PDF

Cycle-to-Cycle Variations Under Cylinder- Pressure- Based Combustion Analysis in Spark Ignition Engines

  • Han, Sung-Bin
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1151-1158
    • /
    • 2000
  • Combustion analysis based on cylinder-pressure provides a mechanism through which a combustion researcher can understand the combustion process. The objective of this paper was to identify the most significant sources of cycle-to-cycle combustion variability in a spark ignition engine at idle. To analyse the cyclic variation in a test engine, the burn parameters are determined on a cycle-to-cycle basis through the analysis of the engine pressure data. The burn rate analysis program was used here and the burn parameters were used to determine the variations in the input parameter-i. e., fuel, air, and residual mass. In this study, we investigated the relationship of indicated mean effective pressure (IMEP), coefficient of variation (COV) of IMEP, burn angles, and lowest normalized value (LNV) in a spark ignition engine in a view of cyclic variations.

  • PDF

Dynamic behavior of axially functionally graded simply supported beams

  • Selmi, Abdellatif
    • Smart Structures and Systems
    • /
    • v.25 no.6
    • /
    • pp.669-678
    • /
    • 2020
  • This paper focuses on the free vibration analysis of axially functionally graded (FG) Euler-Bernoulli beams. The material properties of the beams are assumed to obey the linear law distribution. The complexities in solving differential equation of transverse vibration of composite beams which limit the analytical solution to some special cases are overcome using the Differential Transformation Method (DTM). Natural frequencies and corresponding normalized mode shapes are calculated. Validation targets are experimental data or finite element results. Different parameters such as reinforcement distribution, ratio of the reinforcement Young's modulus to the matrix Young's modulus and ratio of the reinforcement density to the matrix density are taken into investigation. The delivered results prove the capability and the robustness of the applied method. The studied parameters are demonstrated to be very crucial for the normalized natural frequencies and mode shapes.

Energy dissipation demand of compression members in concentrically braced frames

  • Lee, Kangmin;Bruneau, Michel
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.345-358
    • /
    • 2005
  • The response of single story buildings and other case studies are investigated to observe trends in response and to develop a better understanding of the impact of some design parameters on the seismic response of CBF. While it is recognized that many parameters have an influence on the behavior of braced frames, the focus of this study is mostly on quantifying energy dissipation in compression and its effectiveness on seismic performance. Based on dynamic analyses of single story braced frame and case studies, it is found that a bracing member designed with bigger R and larger KL/r results in lower normalized cumulative energy, i.e., cumulative compressive energy normalized by the corresponding tensile energy (${\sum}E_C/E_T$), in both cases.

A study on pattern recognition using DCT and neural network (DCT와 신경회로망을 이용한 패턴인식에 관한 연구)

  • 이명길;이주신
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.3
    • /
    • pp.481-492
    • /
    • 1997
  • This paper presents an algorithm for recognizing surface mount device(SMD) IC pattern based on the error back propoagation(EBP) neural network and discrete cosine transform(DCT). In this approach, we chose such parameters as frequency, angle, translation and amplitude for the shape informantion of SMD IC, which are calculated from the coefficient matrix of DCT. These feature parameters are normalized and then used for the input vector of neural network which is capable of adapting the surroundings such as variation of illumination, arrangement of objects and translation. Learning of EBP neural network is carried out until maximum error of the output layer is less then 0.020 and consequently, after the learning of forty thousand times, the maximum error have got to this value. Experimental results show that the rate of recognition is 100% in case of the random pattern taken at a similar circumstance as well as normalized training pattern. It also show that proposed method is not only relatively relatively simple compare with the traditional space domain method in extracting the feature parameter but also able to re recognize the pattern's class, position, and existence.

  • PDF

A Study on the High Frequency Resonant Inverter of Class D SEPP type using LS-ZVS-LSTC (LS-ZVS-LSTC를 이용한 D급 SEPP형 고주파 공진 인버터에 관한 연구)

  • Park, Dong-Han;Choi, Byeong-Joo;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.260-268
    • /
    • 2020
  • This paper presents the high frequency resonant inverter of class D SEPP(Single-Ended Push Pull) type using LS-ZVS-LSTC, which can reduce the switching losses during the turn-on and turn-off switching time. The analysis of high frequency resonant inverter using LS-ZVS-LSTC(Low-loss Turn-off Snubber Capacitor) proposed in this paper is described in general by adopting the normalized parameters. The operating characteristics of the proposed high frequency resonant inverter were also evaluated by using the control parameters such as the normalized control frequency(μ), the normalized load time constant(τ), the coupling factor(κ) and so on. Based on the characteristic values through the characteristics of evaluation, an example of the design method of the 1.8[kW] class D SEPP type high frequency inverter is suggested, and the validity of the theoretical analysis is verified using the experimental data.