• Title/Summary/Keyword: Normalized parameters

Search Result 459, Processing Time 0.026 seconds

Analysis of The Behavior of Kurtosis By Simplified Model of One Sided Affiliated Impact Vibration

  • Takeyasu, Kazuhiro;Higuchi, Yuki
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.192-197
    • /
    • 2005
  • Among many amplitude parameters, Kurtosis (4-th normalized moment of probability density function) is recognized to be the sensitive good parameter for machine diagnosis. Kurtosis has a value of 3.0 under normal condition and the value generally goes up as the deterioration proceeds. In this paper, simplified calculation method of kurtosis is introduced for the analysis of impact vibration with one sided affiliated impact vibration which occurs towards the progress of time. That phenomenon is often watched in the failure of such as bearings’ outer race. One sided affiliated impact vibration is approximated by one sided triangle towards the progress of time and simplified calculation method is introduced. Varying the shape of one sided triangle, various models are examined and it is proved that new index is a sensitive good index for machine failure diagnosis. Utilizing this method, the behavior of kurtosis is forecasted and analyzed while watching machine condition and correct diagnosis is executed.

Compressibility and Permeability Characteristics of Bentonite-Soil/Sand Mixes (벤토나이트-흙/모래 혼합토의 압축 및 투수 특성 연구)

  • 송창섭;윤병옥;반창현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.2
    • /
    • pp.123-129
    • /
    • 1998
  • Compressibility and permeability properties are the most important input parameters necessary to assess the suitability of core materials in seepage control system construction. To achieve this objective, an experimental investigation was conducted in the laboratory. For the bentonite-soil/sand mixes, consolidation and permeability tests were carried out in the conventional consolidation cell, 6Omm in diameter and 2Omm in height, was modified to perform a falling head type permeability test. From the results, the normalized relationship with respect to void ratio at liquid-limit state $(e_L)$, and the changes of compressibility and permeability for various bentonite-soil/sand mixes were presented. This approach will be helpful in proportioning mixes and predicting corresponding changes in engineering behavior. And it is possible to proportion a mix to arrive at the required compressibility without affecting the permeability.

  • PDF

RADIO FREQUENCY INTERFERENCE FROM FDM-FM SIGNALS ON QAM SIGNAL - DATA IN VOICE CASE - (QAM 신호에 대한 FDM-FM 신호의 간섭 영향 - Data In Voice의 경우-)

  • Ko, Bong-Jin;Cho, Sung-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.864-868
    • /
    • 1987
  • In this paper we have Investigated the effects of two wideband FDM-FM signals on n-ary QAM signal allocated between FDM-FM signals (in DIV case). Here, we assumed that the instantaneous frequency distribution of wideband FDM-FM signal is Gaussian. The numerical results of symbol error rate are given in graphs as the parameters of carrier to noise ratio (CNR), carrier to interference ratio (CIR) and normalized carrier separation between QAM and FDM-FM carrier frequencies.

  • PDF

A Study on Optimization of Neuro-fuzzy System Parameter using Taguchi Method (다구찌 방법을 이용한 뉴로퍼지 시스템 파라미터의 최적화)

  • 김수영;신성철;고창두
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.1
    • /
    • pp.69-73
    • /
    • 2003
  • Neuro-Fuzzy System is to combine merits of fuzzy inference system and neural networks. The neuro-fuzzy system applies a information about given input-output data to fuzzy theories and deals these fuzzy values with neural networks, e.g. first, redefines normalized input-output data as membership functions and then executes thses fuzzy information with backpropagation neural networks. This paper describes an innovative application of the Taguchi method for the determination of these parameters to meet the training speed and accuracy requirements. Results drawn from this research show that the Taguchi method provides an effective means to enhance the performance of the neuro-fuzzy system in terms of the speed for learning and the accuracy for recall.

An Experimental Study on the Effect of Surface Roughness on Nanoscale Adhesion (표면 거칠기가 나노 응착력에 미치는 영향에 관한 실험적 연구)

  • Yang Seung Ho
    • Tribology and Lubricants
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Effect of Surface roughness on nanoscale adhesion was studied experimentally by using colloidal probe technique. Glass micro balls having the radius of $3.3\~17.4{\mu}m$ were glued at the end of AFM cantilevers to prepare colloidal probes. Adhesion force between the colloidal probe and Si-wafer was measured using pull-off force measuring method. Results showed that the measured adhesion forces are not the function of the radius of the glued balls because the ball surfaces are rough. It is also found that roughness parameters such as $R_a,\;R_q\;and\;R_{max}$ do not have important role on nanoscale adhesion. In order to find the effect of surface roughness on nanoscale adhesion, the bearing areas were extracted from the measured topography of glued balls. After normalizing the measured adhesion force with the bearing area, it was found that the normalized adhesion force kept constant as function of the radius of glued ball.

Recognition of Korean Isolated Digits Using a Pole-Zero Model (Polo-Zero 모델을 이용한 한국어 단독 숫자음 인식)

  • ;;Alan Conrad Bovik
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.4
    • /
    • pp.356-365
    • /
    • 1988
  • In this paper, we describe an isolated words recognition system for Korean isolated digits based on a voiced -unvoiced decision algorithm and a frequency domain analysis. The algorithm first performs a voiced-unvoiced decision procedure for the begtinning part of each uttered work using the normalized log energy and zero crossing rate as decision parameters. Based on this decision,. each word is assigned to one of two classes. In order to identify the uttered word within each class, a dynamic time warping algorithm is applied using formant frequencies as the basis for the distance measure. We exploit a pole-zero analysis to measure formant frequencies in each frame. We have observed that pole-zero analysis can provide more accurate estimation of formant frequencies than analysis based on poles only. Experimental recognition rates of 97.3% illustrating the performance of the recognition system was achieved.

  • PDF

Traveling Wave Laser Phase Modulator With Partially Loaded Rectangular Waveguide (부분적으로 장하된 구형도파관에 의한 진행파 레이저 위상변조기)

  • 이문기;신철재
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 1973
  • Traveling wave laser phase modulator, which is consist of rectangular waveguide paritially loaded with electrooptic material, is analysed theoretically. The propagation characteristics, electric field, attenuation, and modulation index are obtained in terms of normalized parameters. It is shown that high modulation index is achieved with relatively low modulating power. And also design procedure of modulator is described with particulary refererenece to KDP.

  • PDF

Evaluation of Alternative Approaches for Nonlinear Cross-anisotropic Parameters on the Small Strain Model based on Triaxial Test Results (삼축 시험을 이용한 미소 변형 모델의 비선형 직교 이방 계수에 대한 평가 방법 고찰)

  • Chun, Sung-Ho;Chung, Choong-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.286-300
    • /
    • 2006
  • Nonlinear cross-anisotropic properties of soil is critical for exact numerical simulation. Theoretically, initial cross-anisotropic properties can be evaluated from triaxial tests with bender element tests, and nonlinear cross-anisotropic properties over initial strain level cannot be evaluated from triaxial tests. In this study, a supposed condition among nonlinear cross-anisotropic properties is suggested to calculate nonlinear cross-anisotropic properties from triaxial tests. Maximum strain and incremental strain energy are applied to combine triaxial test results and theoretical normalized shear modulus curve, respectively Based on combined results, nonlinear cross-anisotropic properties are calculated. Numerical simulation for triaxial tests Is carried out to verify the applicability of the supposed condition with calculated cross-anisotropic properties and simplified nonlinear cross-anisotropic model.

  • PDF

A Study on the Structure and Adaptive Methods for Robust Adaptive Control and its Simulation (견실한 적응제어를 위한 구조 및 적응 방법에 관한 인구와 시뮬레이션)

  • 윤태웅;최종호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.7
    • /
    • pp.484-491
    • /
    • 1987
  • A sufficent condition for the robust control of the adaptive control system is presented under the convergence of the parameters of the adaptive system. The plant in the adaptive control system is a stable system which includes the unmodelled dynamics and can be approximated by a minimum phase system. It is shown that modified structure which Kosut and Friedlander suggested satisfies the sufficient condition more easily than the original structure without modification. It is also shown by computer simulation that the modified structure and/ or the adaptation method using the normalized input and output data or filtered input and output data can improve the robustness of the adaptive control system.

  • PDF

Characteristic analysis of self tuning controlled current fed high frequency resonant inverter (자려식 전류형 고주파 공진 인버터의 특성해석)

  • Song, J.H.;Kim, D.H.;Noh, C.K.;Hwang, G.H.;Lee, B.S.;Sim, K.Y.;Jung, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2638-2640
    • /
    • 1999
  • This paper proposes a current-fed type high frequency inverter using a soft switching technology Zero-Voltage-Switching to reduce turn on and off loss at the switching. The analysis of the proposed circuit was described by using normalized parameter and operating characteristics have been evaluated as to switching frequency and parameters. In the future, the proposed circuit is considered to be useful for induction heating applications.

  • PDF