• Title/Summary/Keyword: Normal value

Search Result 3,440, Processing Time 0.028 seconds

Videostrobokymographic Analysis of the Benign Vocal Folds Lesions (양성 성대 질환에서의 Videostrobokymography 소견)

  • 김동영;성명훈;김광현;최승호;왕수건
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.5-17
    • /
    • 2002
  • Objectives : Videostrobokymography(VSK) has been recently developed and reported by Sung et at. We aimed to analyze vibratory patterns and objective parameters in various benign vocal fold lesions using VSK, and examine the efficacy of VSK in clinical application. Materials and Methods : Using VSK, we analyzed the vibration pattern of normal vocal fold and various benign lesions, such as nodules, polyps, cysts, Reinke's edema and unilateral vocal fold paralysis. We also calculated objective parameters, open quotient and asymmetric index, and compared them with mean values of parameters in normal controls. Results : In nodules, polyps, and cysts, the open quotient on the site of the lesion was similar to the mean value in normal controls, however, on the other part of the vocal folds it was much larger than normal mean value. In Reinke's edema, irregular and asymmetric vibration was observed. The posterior portion of the vocal folds showed larger open quotients than the anterior portion. In the unilateral vocal fold paralysis, irregular vocal folds vibration and incomplete closure of the vocal folds were documented. Much larger asymmetric indices were calculated in the unilateral vocal fold paralysis than in normal controls and other lesions. The asymmetric index could be a good quantitative parameter of vibration from a patient with vocal fold paralysis. Conclusion : This study demonstrated that VSK could generate clear quantitative documentations of fine vibrations of vocal folds in many different benign lesions. VSK has a potential as an effective tool for quantitative analysis of vibratory patterns of the vocal folds iii clinical settings.

  • PDF

A Study on the Size of TMD Patient's Condyle Head (악관절장애환자의 하악과두 크기에 관한 연구)

  • Lee, Doo-Hee;Oh, Soon-Ho;Suh, Chang-Ho;Kim, Joon-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.417-422
    • /
    • 2001
  • Objective: In many TMD cases, deformed and reduced condyle heads were frequently observed. This study was prepared to compare the dimensions between normal and symptomatic condyles, using MR images. Materials: One hundred and twenty one patients with clinical signs and MRI-confirmed diagnosis of disc displacement were selected for this study. Thirty eight TMJs from nineteen asymptomatic volunteers who had no clinical symptoms and no disc displacement on sagittal and coronal view of MRI, were served as normal. Methods: Symptomatic condyles were classified according to the severity of the anterior disc displacement. The amount of anterior disc displacement was evaluated at sagittal section, and they were classified into 4 groups as normal(N), little(G0), mild(G1), moderate(G2) and severe displacement(G3). The dimentions of condyle were measured at the 200% magnified view, by digitizing program. All dimensions were compared among each groups on the central section of sagittal and coronal views, and the statistical analysis was performed. Results: The mean value of anteroposterior length of normal condyle was $0.79{\pm}0.13cm$ at sagittal section and mediolateral length was $2.12{\pm}0.22cm$ on coronal section. The mean value of anteroposterior length of symptomatic condyle was $0.67{\pm}0.16cm$ at sagittal section and mediolateral length was $1.97{\pm}0.28cm$ on coronal section. Conclusions: The size of symptomatic condyle was smaller than normal TMJ. The size of condyle was decreased as the amount of the disc displacement was increased. The dimensional change was found on the anterior articular surface of condyle at the mild or moderate disc displacement. And at the case of severe disc displacement, dimensional change was found on the superior articular surface.

  • PDF

Correlation Study between Electrogastrography and Heart Rate Variability in Dyspeptic Patients (소화불량 환자에서 위전도 검사와 HRV 검사와의 연관성 연구)

  • Kim, So-Yeon;Han, Chang-Woo;Park, Seong-Ha;Kwon, Jung-Nam;Lee, In;Hong, Jin-Woo;Choi, Jun-Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.532-538
    • /
    • 2012
  • The aim of this study was to find correlation between EGG and HRV parameters in dyspeptic patients. 39 patients (male 8, female 31) were enrolled. EGG and HRV was measured in all patients. EGG parameters like % of gastric slow wave and power ratio were used to classify patients as normal or abnormal EGG groups. HRV parameters which were included TP (total power), LF(low frequency density), HF (high frequency density), and LF/HF ratio were compared between them. EGG parameters were compared among normal, sympathetic hyperactivity, and parasympathetic hyperactivity groups classified by LF/HF ratio. There was no difference in HRV parameters between normal and abnormal EGG groups. Comparing EGG parameters among normal, sympathetic hyperactivity, and parasympathetic hyperactivity groups, both sympathetic and parasympathetic hyperactivity groups had lower value of postprandial regularity of gastric slow wave than normal group. Abnormal value of LF/HF ratio(both sympathetic and parasympathetic hyperactivity) may be related with disturbance of electrical gastric activity in patients with dyspepsia.

The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF

Textures and Sensible Images on Structural Properties of Washable Wool and Normal Wool Knit Fabrics (Part II) -Focus on Preferences- (워셔블 울과 노멀 울편성물의 구성특성에 따른 질감 및 감성이미지 (제2보) -구성특성에 따른 선호도를 중심으로-)

  • Kim, Hyun-Ah;Ryu, Hyo-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.5
    • /
    • pp.501-511
    • /
    • 2012
  • This study examines the effect of structural properties of F/W wool knit fabrics for woman's knitwear on the preferences for textile designing through analyzing the relationship among the structural properties, mechanical properties, objective hand measurements, and preferences. The 'knit structure' was determined to be the most important parameter in rating preferences, apart from the 'preference for cardigans'. Consumers preferred washable wool to normal wool when comparing a normal wool knit with a washable wool knit on a 'knit structure' factor. Preferred structural properties showed a similar tendency 'preference for fabric' and the 'preference for cardigans', 'preference for sweaters' and 'preference for vests'. The 'sophisticated/feminine' factor showed a correlation with 'fabric preference' and the texture and sensible images had a similar effect on fabric preferences. In the relationship between objective hand measurements and fabric preferences, the KOSHI value had a negative coefficient and the THV value had a positive correlation with fabric preferences. In conclusion, we found a consumer preference for more flexible fabrics.

Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector (커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석)

  • Kim, Sang-Chul;Kim, Doo Hyun;Kang, Shin Uk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

Efficacy of Recombinant Human Erythropoietin(rhu-EPO)

  • Kim, Dong-Hwan;Ahn, Byoung-Ok;Park, Jang-Hyeon;Lee, Sung-Hee;Kim, Won-Bae
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.312-316
    • /
    • 1998
  • Efficacy and in vivo bioassay of recombinant human erythropoietin (rho-EPO), was investigated. Efficacy studies were conducted in normal, and cisplatin-induced anemic rats. Normal and anemic animals were treated intravenously with rhu-EPO for 5 days, and the changes in the number of red blood cells (RBC), hemoglobin concentration (Hb), hematocrit value (Hct) and percentage reticulocyte value (Ret, reticulocyte/RBC) were examined. In normal rats, rho-EPO significantly increased RBC, Hb, Hct and Ret at the doses of 50∼ 1,250 lU/kg/day in a dose-dependent fashion. Cisplatin-induced anemic rats showed significant increase of RBC, Hb, Hct and Ret after administration of rho-EPO (50-200 lU/kg/day) in a dose-dependent manner. These changes of hematological parameters disappeared gradually after cessation of the treatment. The in vivo bioassay results in polycythemic mice showed that rho-EPO had 90% of bioactivity compared to NIBSC standard rhu-EPO. These results suggest that rho-EPO might be useful for the therapy of anemia originated from renal failure and chemotherapy-induced anemia.

  • PDF

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.4
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.

A Study on Isokinetic Strength Ratios of Hip joints in Above-knee Amputees (대퇴절단환자의 고관절 등속성근력비율에 관한 연구)

  • Song, Chang-Ho;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.74-82
    • /
    • 2003
  • The purpose of this study is to provide guideline of muscle strengthening exercise for preparing ambulation by presenting suitable ratio of muscle power of agonist & antagonist, and that of concentric & eccentric contraction on behalf of amputee's normal ambulation training and it's strenthening as well. 7 Subjects who have femur amputee for experimental group were able to ambulate naturally without inconvenience and 20 adult subjects of comparison group for comparison were considered to be free from disturbance of ambulation. The method of study was to measure the muscle power of hip pint, was to figure out the ratio of agonist & antagonist, concentric contraction & eccentric contraction, and was to find out mean and standard deviation of each measurement. Every numerical value of comparison was tested by Mann-whitney and comparison group's comparison between left & right value was done with t-test. Results are as followings : 1) Extension force was stronger than flexor force and had no remarkable difference(p<0.05) 2) For normal adults, adduction farce was stronger than abduction force and for amputees, abduction force was stronger while adduction force was the same as the normal without showing remarkable difference(p<0.05) According the result above, I make an assumption that maintaining a proper ratio of muscle power on strengthening exercise for amputee's ambulation training & rehabilitation and finally bring out an improvement of transfer and ambulation.

  • PDF

Slope Stability Evaluation System of Sanitary Landfill on Soft Ground and Its Reliability (연약지반상 위생매립지 안정성 평가에 대한 문제점 분석과 개선방향)

  • 우동찬;송좌빈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1997.03a
    • /
    • pp.161-168
    • /
    • 1997
  • The purpose of this study is to evaluate the possibility of normalization of the distibutions of soil parameters taken from soft ground and the reliability of the safety factors of specific objects on it, including sanitary landfill. Through this study it is found that distributions of soil parameters could be adjusted to appropriate normal distributions as possibility density functions(PDF), and that especially the group of initial cohesions and the coresponding safety factors has a perfect linear correlation. According to those results the PDF to initial cohesion as possibility parameter can not only be tmsformed to the PDF to safety factor but also, conseqently, the reliability of the safety factor(SF) simply based on the mean value of soil parameter(Co) can be calculated or easily picked up from the standrad normal distribution table. It is therefore concluded that even though calculated values of safety factors are over any standard requirements some possibility of risk both to the objects and natural soft ground could be still existing, and also a new standard value for this slope stability control system should be derived just by adjusting old one according to the magnitude of risk possibility.

  • PDF