• 제목/요약/키워드: Normal operation

검색결과 2,146건 처리시간 0.032초

A HALF-CENTERED STAR-OPERATION ON AN INTEGRAL DOMAIN

  • Qiao, Lei;Wang, Fanggui
    • 대한수학회지
    • /
    • 제54권1호
    • /
    • pp.35-57
    • /
    • 2017
  • In this paper, we study the natural star-operation defined by the set of associated primes of principal ideals of an integral domain, which is called the g-operation. We are mainly concerned with the ideal-theoretic properties of this star-operation. In particular, we investigate DG-domains (i.e., integral domains in which each ideal is a g-ideal), which form a proper subclass of the DW-domains. In order to provide some original examples, we examine the transfer of the DG-property to pullbacks. As an application of the g-operation, it is shown that w-divisorial Mori domains can be seen as a Gorenstein analogue of Krull domains.

이수관리곡선에 의한 증고저수지의 하천유지유량 공급 가능성 평가 (Evaluation of Supplying Instream Flow by Operation Rule Curve for Heightening Irrigation Reservoir)

  • 이재남;노재경
    • 농업과학연구
    • /
    • 제37권3호
    • /
    • pp.481-490
    • /
    • 2010
  • Baekgog reservoir is located in Jincheon county, Chungbuk province, of which full water levels will be heightened from EL. 100.1 m to EL. 102.1 m, and total storages from 21.75 $Mm^3$ to 26.67 $Mm^3$. The simulation for reservoir inflow was conducted by DAWAST model. The annual average irrigation water was estimated to 33.19 $Mm^3$ supplied to 2,975 ha and the instream flows could be allocated with 0.14 mm/d from October to April with annual average of 2.52 $Mm^3$. The operation rule curve was drawn using inflow, irrigation, and instream flow requirements data. The reservoir water storage was simulated on a daily basis in case of both normal and withdrawal limit operation. In case of normal operation, the annual average irrigation water supply increased from 31.95 $Mm^3$ to 33.32 $Mm^3$, the instream water supply from 2.40 $Mm^3$ to 2.44 $Mm^3$, the water storages from 15.74 $Mm^3$ to 19.88 $Mm^3$, and the water supply reliability from 77.3 % to 81.6 %. In case of operation with withdrawal limit, the amount of instream water supply was 2.52 $Mm^3$ from reservoir regardless of the condition while the water storage increased from 16.77 $Mm^3$ to 20.65 $Mm^3$. The irrigation water supply capacity was appropriate for the case of normal operation with 2 m heightened condition. The present instream water supply capacity was 35,000 $m^3$/d (6.86 $Mm^3$/y) while 42,000 $m^3$/d (8.36 $Mm^3$/y) in 2 m heightened condition in case of withdrawal limit operation.

개의 장문합술에 있어 봉합 문합술과 Stapler 문합술의 비교 (Comparison of Sutured Intestinal Anastomosis and Stapler Intestinal Anastomosis in Dogs)

  • 박대식;구자민;성용증;이희천;장홍희;이효종;연성찬
    • 한국임상수의학회지
    • /
    • 제21권4호
    • /
    • pp.343-348
    • /
    • 2004
  • This study was carried out to investigate the difference between sutured anastomosis and stapler anastomosis (open lumina technique) of jejunum in dogs. Fifteen mongrel-breed female dogs weighting 4 to 6 kgs were allocated to three groups; sutured end-to-end anastomosis (Group I), sutured side-to-side anastomosis (Group II) and stapler anastomosis (Group III), five dogs per each group. All dogs in different anastomosis pattern were compared with time for total operation and suture elapsed for intestines to anastomose, clinical signs, status of feces, complications for 14 days after operation. The total operation time and suture time needed for intestinal anastomosis were significantly(p<0.05) shorter in Group III than Group I and II. All dogs showed no significant difference in vitality, appetite, vomiting between groups for 14 days after operation. All dogs, except one dog in Group II, showed normal vitality and appetite since 7-8 days after operation. Initial return of fecal passage showed in all dogs 8 days after operation and thereafter normal feces were observed in most of the dogs. According to results, all dogs with normal vitality and appetite for 8 days showed good prognosis. In complications after operation, only one dog in Group II showed dehiscence of anastomotic site. There was significant(p<0.05) differences between groups in speed of operation. And all dogs, except one dog in Group II, showed good clinical condition and prognosis. In conclusion, the stapler anastomosis is considered to be more reliable, faster, and precision method compared to the sutured anastomosis for intestinal anastomosis in dogs.

원격지 수도시설 펌프운영 패턴의 자동화 알고리즘 구현 (A1gorithm Embodiment for Automatic Pump Operation Pattern)

  • 변두균;윤영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2474-2476
    • /
    • 2003
  • An algorithm was embodied to automatic pump operation Pattern for remote control located in 60 km far. This automation pattern included least cost operation, peak load time response, pump operation time balancing etc. It was programmed four kind of operation mode as following; normal operation nude, before peak load time nude, peak load time operation, after peak load time operation.

  • PDF

병렬운전 변압기 전압제어 및 저압축 모선보호방식연구 (A Study of Voltage Control for Lower Side Parallel Transformer)

  • 윤기섭;백승도;최종혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.233-236
    • /
    • 2001
  • Parallel operation scheme to several transformers is adopted because of the load increase, economic problem, or load shedding. For the transformer's parallel operation, loads proportional to each transformer's capacity must be allotted, and circulation currents must be limited as much as without causing any problem in a real operation. But, both transformers in parallel operation can be tripped when either faults at lower voltage side of a transformer or faults in a bus occurs. Therefore, parallel operation scheme to distribution transformers in Korea is not adopted in a normal state but only when loaded or load-shedded. These are due to the insufficiency of the construction in communication network and AVR scheme. Besides that, those are because bus bar protection scheme to lower voltage side of a transformer is not applied. In spite of enormous initial investment costs, advanced countries take so much account of power system reliability and stable supply that they adopt the parallel operation scheme in a normal state. One of the problems in parallel operation is the overheat of transformers due to the excessive circulation currents. This paper presents the scheme that controls voltages between both transformers using circulation currents that occurs in parallel operation.

  • PDF

Investigation on effect of neutron irradiation on welding residual stresses in core shroud of pressurized water reactor

  • Jong-Sung Kim;Young-Chan Kim;Wan Yoo
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.80-99
    • /
    • 2023
  • This paper presents the results of investigating the change in welding residual stresses of the core shroud, which is one of subcomponents in reactor vessel internals, performing finite element analysis. First, the welding residual stresses of the core shroud were calculated by applying the heat conduction based lumped pass technique and finite element elastic-plastic stress analysis. Second, the temperature distribution of the core shroud during the normal operation was calculated by performing finite element temperature analysis considering gamma heating. Third, through the finite element viscoelastic-plastic stress analysis using the calculated temperature distribution and setting the calculated residual stresses as the initial stress state, the variation of the welding residual stresses was derived according to repeating the normal operation. In the viscoelastic-plastic stress analysis, the effects of neutron irradiation on mechanical properties during the cyclic normal operations were considered by using the previously developed user subroutines for the irradiation agings such as irradiation hardening/embrittlement, irradiation-induced creep, and void swelling. Finally, the effect of neutron irradiation on the welding residual stresses was analysed for each irradiation aging. As a result, it is found that as the normal operation is repeated, the welding residual stresses decrease and show insignificant magnitudes after the 10th refueling cycle. In addition, the irradiation-induced creep/void swelling has significant mitigation effect on the residual stresses whereas the irradiation hardening/embrittlement has no effect on those.

ECC 연산을 위한 가변 연산 구조를 갖는 정규기저 곱셈기와 역원기 (Scalable multiplier and inversion unit on normal basis for ECC operation)

  • 이찬호;이종호
    • 대한전자공학회논문지SD
    • /
    • 제40권12호
    • /
    • pp.80-86
    • /
    • 2003
  • 타원곡선 암호(Elliptic Curve Crypto-graphy : ECC)는 기존의 어떤 공개키 암호 시스템보다 우수한 비트 당 안전도를 제공하고 있어 최근 큰 관심을 끌고 있다. 타원곡선 암호 시스템은 보다 작은 키 길이를 갖고 있어 시스템의 구현에 있어서 작은 메모리 공간과 적은 처리 전력을 필요로 하므로 다른 암호화 방식에 비해 임베디드 어플리케이션에 적용하는데 유리하다 본 논문에서는 제곱 연산이 용이한 정규기저로 표현된 유한체에서의 곱셈기를 구현하였다. 이 곱셈기는 타원곡선 암호에서 사용되는 GF(2/sup 193/) 상에서 구현하였고, Massey와 Omura가 제시한 병렬 입력-직렬 출력 곱셈기의 구조를 변형하여 출력의 크기와 설계면적을 조절할 수 있다. 또한 제안한 곱셈기를 적용하여 정규기저 역원기를 구현하였다. 곱셈기와 역원기는 HDL을 이용하여 설계하구 0.35㎛ CMOS 셀 라이브러리를 이용하여 구현하였으며 시뮬레이션을 통해 동작과 성능을 검증하였다.

고속 전환특성을 가진 자동부하전환 개폐기의 구동메커니즘의 동적 해석 (Dynamic Analysis of Driving Mechanism for ALTS with High-Speed Transfer Characteristics)

  • 정원선;권병희;안길영;오일성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1530-1535
    • /
    • 2003
  • The automatic load transfer switch (ALTS) typically automatically transfers electrical loads from a normal electrical power source to an emergency electrical power source upon reduction or loss of normal power source voltage. It can also automatically re-transfer the load to the normal power source when the normal voltage has been restored within acceptable limits. The transfer operation of ALTS is accomplished by a spring-driven linkage mechanism. In this paper we build a dynamic model of driving mechanism for ALTS using ADAMS and checked the characteristics of the transfer operation. Finally we performed a detailed design of the driving mechanism through results of analysis and confirmed it to satisfy design requirements.

  • PDF

계통상태를 고려한 송전선의 ELF 전자계 (ELF Electric and Magnetic Fields under the Transmission Line Including Electric Power System States)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.89-96
    • /
    • 1996
  • This paper presents a study on the analysis and evaluation for ELF( Extremely Low Frequency) electric and magnetic fields under the transmission line according to the power system states. The power system states are classified into two types, normal state resulting from normal operation and alert state from outages. The current in a system is changed continually owing to the load fluctuations even in a normal operation. To calculate the current of the concerned line in a normal state, the system load level is devided into light, base and heavy load level. In case of contingency, an efficient algorithm based on matrix inversion lemma is developed to figure out the current changes. In order to analyze the variations of ELF field caused by the current fluctuations the electrostatic field approach which is far simpler than the electromagnetic field one based on Maxwell equation is introduced in this paper. The suggested method is applied to the IEEE 14 bus system to demonstrate the usefulness.

  • PDF

Normal basis를 이용한 고속 타원곡선암호(ECC)시스템의 설계 (Design of High-speed Elliptic Curve Cryptosystem using normal basis)

  • 윤여준;김종태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.773-776
    • /
    • 2003
  • This paper presents new hardware implementation of the ECC(Elliptic Curve Cryptography) algorithm that is improved in speed and stability. We proposed new datapath that changed square's position so that we can reduce required number of cycles for addition operation between two points by more than 30%. We used Massey-Omura parallel multiplier adopted Normal basis for fast scalar multiplications. Also the use of the window non-adjacent form (WNAF) method can reduce addition operation of each other different points. We implemented ECC system with GF($2^{196}$), and this system was designed and verified by VHDL.

  • PDF