• Title/Summary/Keyword: Normal Transmission

Search Result 595, Processing Time 0.026 seconds

The Effect of Breathing Meditation Qigong Therapy on the Recovery of Olfactory Disorders and Voice Handicap Index in Parkinson's Disease Patients (호흡명상기공테라피가 파킨슨병 환자의 후각 및 음성 기능장애 개선에 미치는 효과)

  • So Jung An;Hun Mo Ahn
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.23 no.1
    • /
    • pp.10-29
    • /
    • 2024
  • Objective : The purpose of this study is to determine whether An's breathing meditation qigong therapy (ABMQT) delivers bioenergy to the frontal lobe, prefrontal lobe, the olfactory tract in the mesolimbic pathway, olfactory bulb, CV22, CV21, olfactory area and vocal-related areas in Parkinson's disease (PD) patients to help improve olfactory disorders (anosmia) and vocal functions. Methods : The subjects of this study were 4 patients with idiopathic PD (3 males/1 female, 65.0±NA/68.7±10.2 years old). ABMQT was applied once a week, 120 minutes per session for 12 weeks in a non-invasive and noncontact manner, and the test before and after ABMQT application included olfactory impairment test the Korean version of Sniffin' stick test (KVSS), voice acoustic test, aerodynamic test, vocal handicap index (VHI-30), and auditory perception scale test tools. The results before and after the experiment were analyzed assuming a normal distribution, and a chi-square test was performed using a continuity correction, and the significance level was set to p<0.05. And the medical diagnosis and findings of the examiner (doctor in charge) before and after the experiment were described. Results : KVSS was significant as 0.2±0.5 and 9.0±0.0 before and after the experiment. There was no significant difference between the voice acoustic test FO and Jitter, the vocal aerodynamic test MPT, SP, AE, the vocal disorder index test, and the auditory perception test. However, the medical diagnosis findings of four study subjects showed that olfactory disorders, voice disorders, and laryngeal function were improved before and after the application of ABMQT. Conclusions : The breathing meditation qigong program showed significant effects on improving the olfactory disorders (anosmia) and speech function of each study subject. However, to produce meaningful results, it is thought that experiments involving a larger number of research participants are necessary, and additional blood and FMRI tests are conducted to verify metabolic activities and the olfactory neuron signal transmission system.

A Study of Serum HBV Markers in Term Pregnant Women and Their Neonates (만삭임부 및 신생아의 혈청 B형간염 바이러스 표식자에 관한 연구)

  • Lee, Tae-Hyung;Park, Wan-Seok;Kim, Sung-Rim;Lee, Kang-Wan;Lee, Sung-Ho;Chung, Wun-Young
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.2
    • /
    • pp.121-129
    • /
    • 1987
  • To evealuate the status of hepatitis B virus infection in the mothers and neonates and to determine the maternal-neonatal transmission of hepatitis B virus, 2,276 term pregnant women were screened for the presence of serum HBsAg, at the Department of Obstetrics and Gynecology, Yeungnam University Hospital, during the period of 18 months from Jan. 1986 to Jun. 1987, and the sera of sixty-six HBsAg carrier mothers and their neonates were tested for HBV markers and liver enzymes. The results were as follows : 1. The prevalence rate of asymptomatic HBsAg carrier in the term pregnant women was 4.7%(53/1,279). 2. Positive rates of HBsAg and anti-HBs 10 the sera of sixty-six neonates born to asymptomatic HBsAg carrier mothers were 12.1% and 9.1%, respectively. Transient elevation of SGOT(three to four times of upper normal limit) was detected in one of eight HBsAg-positive neonates and one of six anti-HBs positive neonates. 3. Positive rates of anti-HBc, HBeAg and anti-HBe to the sera of sixty-six asymptomatic HBsAg carrier term pregant women were 93.9%, 45.5% and 50%, respectively. The rates of transmission of maternal anti-HBc, HBeAg and anti-HBe to the neonates were 85.5%(53/62), 90%(27/30) and 87.9%(29/33). respectively. 4. Serum HBsAg was detected in four of thirty neonates born to HBeAg positive HBsAg carrier mother, three of thirty-three neonates born to anti-HBe positive HBsAg carrier mothers, and one of three neonates born to both HBeAg and anti-HBe negative HBsAg carrier mothers.

  • PDF

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

The current status and control measures of BSE in the worldwide (국내, 외 광우병의 발생 현황과 대응 방안)

  • Yoo, Han-Sang
    • 한국환경농학회:학술대회논문집
    • /
    • 2009.07a
    • /
    • pp.273-282
    • /
    • 2009
  • The transmissible spongiform encephalopathies (TSEs) disease group are fatal neurodegenerative disorders affecting a wide range of hosts. The group includes kuru and Creutzfeldt-Jakob disease (CJD) in humans, scrapie in sheep and goats and Bovine spongiform encephalopathy (BSE) in cattle. The exact nature of the infectious agent involved in the transmission of these diseases remains controversial. However, a central event in their pathogenesis is the accumulation in infected tissues of an abnormal form of a host-encoded protein, the prion protein (PrP). Whereas the normal cellular protein is fully sensitive to protease ($PrP^{sen}$), the disease-associated prion protein ($PrP^d$) is only partly degraded ($PrP^{res}$), its amino-terminal end being removed. BSE was first reported in the mid-80s in the UK. Ten years later, a new form of human prion disease, variant CJD (vCJD) developed in the wake of the BSE epidemic, and there is now strong scientific evidence that vCJD was initiated by the exposure of humans to BSE-infected tissues, thus indicating a zoonotic disease. However, the ban on the feeding of animal-derived proteins to ruminants, and the apparent lack of vertical transmission of BSE, have led to a decline in the incidence of the disease within cattle herd and therefore, an assumed decreased risk for human contacting vCJD. The origin of the original case(s) of BSE still remains an enigma even though three hypotheses have been raised. Hypotheses are i) sheep- or goat-derived scrapie-infected tissues included in meat and bone meal fed to cattle, ii) a previously undetected sporadic or genetic bovine TSE contaminating cattle feed or iii) originating from a human TSE through animal feed contaminated with human remains. A host cellular membrane protein ($PrP^C$), which is abundant in central nervous system tissue, appear to be conformationally altered in the diseased host into a prion protein ($PrP^{Sc}$). This $PrP^{Sc}$ is detergent insoluble and partially protease-resistant ($PrP^{res}$). The term $PrP^{res}$ is normally used to describe the protein detected after protease treatment, in techniques such as Western immunoblotting, and enzyme-linked immunosorbant assay using fresh/frozen tissue. Immunohistochemistry may performed with formalin-fixed tissues. Also, clinical signs of the BSE are one of the major diagnostic indicators. Recently, atypical forms (known as H- and L-type) of BSE have appeared in several European countries, Japan, Canada and the United States. An unusual case was also reported in a miniature zebu. The atypical BSE fall into two groups based on the relative molecular mass (Mm) of the unglycosylated $PrP^{res}$ band relative to that of classical BSE, one of the higher Mm (H-type) and the other lower (L-type). Both types have been detected worldwide as rare cases in older animals, at a low prevalence consistent with the possibility of sporadic forms of prion diseases in cattle. This raises the unwelcome possibility that vCJD could increase in the human population. Now, active surveillance program against BSE is going on in Korea. In regional veterinary service lab, ELISA is applied to screen the BSE in slaughter and confirmatory tests by Western immunoblotting and immunohistochemisty are carried out if there are positive or suspect in the screening test. Also, the ruminant feed ban is rigorously enforced. Removal of specified risk materials such as brain and spinal cord from cattle is mandatory process at slaughter to prevent the infected material from entering the human food chain.

  • PDF

Verification of Clinical Usefulness of Jaw Tracking in IMRT (IMRT에 있어 Jaw Tracking 의 임상적 유용성 검증)

  • Kim, Jin-young;Kim, Ki-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • Intensity-modulated radiotherapy(IMRT) has disadvantages such as increasing the low doses of irradiation to normal tissues and accumulated dose for the whole volume by leakage and transmission of the Multi Leaf Collimator (MLC). The accumulated dose and low dose may increase the occurrence of secondary malignant neoplasms. For this reasons, the jaw tracking function of the TrueBeam (Varian Medical Systems, Palo Alto, CA) was developed to reduce the leakage and transmission dose of the MLC with existing linear accelerators. But quantitative analysis of the dose reduction has not been verified. Therefore, in the present study, we intended to verify the clinical possibility of utilizing the jaw tracking function in brain tumor with comparison of treatment plans. To accomplish this, 3 types of original treatment plans were made using Eclipse11 (Varian Medical Systems, Palo Alto, CA): 1) beyond 2 cm distance from the Organs At Risk (OARs); 2) within 2 cm distance from the OARs; and 3) intersecting with the OARs. Jaw tracking treatment plans were also made with copies of the original treatment planning using Smart LMC Version 11.0.31 (Varian Medical Systems, Palo Alto, CA). A comparison between the 2 types of treatment planning methods was performed using the difference of the mean dose and maximum dose to the OARs in cumulative Dose Volume Histogram (DVH). In the DVH comparison, the maximum difference of 0.5 % was observed between the planning methods in the case of over 2 cm distance, and the maximum of 0.6 % was obtained for within the 2 cm distance. For the case intersecting with the OAR, the maximum difference of 2 % was achieved. According to these results, it could be realized that the differences of mean dose and maximum dose to the OARs was larger when the OARs and PTV were closer. Therefore, treatment plans with the jaw tracking function consistently affected the dose reduction and the clinical possibility could be verified.

Development of a TBM Advance Rate Model and Its Field Application Based on Full-Scale Shield TBM Tunneling Tests in 70 MPa of Artificial Rock Mass (70 MPa급 인공암반 내 실대형 쉴드TBM 굴진실험을 통한 굴진율 모델 및 활용방안 제안)

  • Kim, Jungjoo;Kim, Kyoungyul;Ryu, Heehwan;Hwan, Jung Ju;Hong, Sungyun;Jo, Seonah;Bae, Dusan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.3
    • /
    • pp.305-313
    • /
    • 2020
  • The use of cable tunnels for electric power transmission as well as their construction in difficult conditions such as in subsea terrains and large overburden areas has increased. So, in order to efficiently operate the small diameter shield TBM (Tunnel Boring Machine), the estimation of advance rate and development of a design model is necessary. However, due to limited scope of survey and face mapping, it is very difficult to match the rock mass characteristics and TBM operational data in order to achieve their mutual relationships and to develop an advance rate model. Also, the working mechanism of previously utilized linear cutting machine is slightly different than the real excavation mechanism owing to the penetration of a number of disc cutters taking place at the same time in the rock mass in conjunction with rotation of the cutterhead. So, in order to suggest the advance rate and machine design models for small diameter TBMs, an EPB (Earth Pressure Balance) shield TBM having 3.54 m diameter cutterhead was manufactured and 19 cases of full-scale tunneling tests were performed each in 87.5 ㎥ volume of artificial rock mass. The relationships between advance rate and machine data were effectively analyzed by performing the tests in homogeneous rock mass with 70 MPa uniaxial compressive strength according to the TBM operational parameters such as thrust force and RPM of cutterhead. The utilization of the recorded penetration depth and torque values in the development of models is more accurate and realistic since they were derived through real excavation mechanism. The relationships between normal force on single disc cutter and penetration depth as well as between normal force and rolling force were suggested in this study. The prediction of advance rate and design of TBM can be performed in rock mass having 70 MPa strength using these relationships. An effort was made to improve the application of the developed model by applying the FPI (Field Penetration Index) concept which can overcome the limitation of 100% RQD (Rock Quality Designation) in artificial rock mass.

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Changes in Distribution and Morphology of Rat Alveolar Macrophage Subpopulations in Acute Hyperoxic Lung Injury Model (고농도 산소로 유발한 흰쥐의 급성폐손상모델에서 폐포대식세포 아형군의 분포와 형태 변화)

  • Shin, Yoon;Lee, Sang-Haak;Yoon, Hyoung-Kyu;Lee, Sook-Young;Kim, Seok-Chan;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.478-486
    • /
    • 2000
  • Background : In acute lung injury, alveolar macrophages play a pivotal role in the inflammatory process during the initiation phase and in the reconstruction and fibrosis process during the later phase. Recently, it has been proven that alveolar macrophages are constituted by morphologically, biochemically and immunologically heterogenous cell subpopulations. The possibility of alterations to these characteristics of the alveolar macrophage population during lung disease has been raised. To investigate such a possibility a hyperoxic rat lung model was made to check the distributional and morphological changes of rat alveolar macrophage subpopulation in acute hyperoxic lung injury. Method : Alveolar macrophage were lavaged from normal and hyperoxic lung injury rats and separated by discontinuous gradients of percoll. After cell counts of each density fraction were accessed, the morphomeric analysis of alveolar macrophages was performed on cytocentrifuged preparations by transmission electron micrograph. Result : 1. The total alveolar macrophage cell count significantly increased up to 24 hours after hyperoxic challenge (normal control group $171.6{\pm}24.1{\times}10^5$, 12 hour group $194.8{\pm}17.9{\times}10^5$, 24 hour group $207.6{\pm}27.1{\times}10^5$, p<0.05). oHoHH However the 48 hour group ($200.0{\pm}77.8{\times}10^5$) did not show a significant difference. 2. Alveolar septal thickness significantly increased up to 24 hours after hyperoxic challenge(normal control group $0.7{\pm}0.2{\mu}m$, 12 hour group $1.5{\pm}0.4{\mu}m$, 24 hour group $2.3{\pm}0.4{\mu}m$, p<0.05). However the 48 hour group did not show further change ($2.5{\pm}0.4{\mu}m$). Number of interstitial macrophage markedly increased at 24 hour group. 3. Hypodense fraction(fraction 1 and fraction 2) of alveolar macrophage showed a significant increase following hyperoxic challenge ($\beta=0.379$.$\beta=0.694$. p<0.05) ; however, fraction 3 was rather decreased following the hyperoxic challenge($\beta=0.815$. p<0.05), and fraction 4 showed an irregular pattern. 4. Electron microscopic observation of alveolar macrophage from each fraction revealed considerable morphologic heterogeneity. Cells of the most dense subfraction(fraction 4) were small, round, and typically highly ruffled with small membrane pseudopods. Cells of the least dense fraction (fraction 1) were large and showed irregular eccentric nucleus and high number of heterogenous inclusions. Conclusion : In conclusion, these results suggest that specific hypodense alveolar macrophage subpopulation may play a an important role in an acute hyperoxic lung injury model But further study, including biochemical and immunological function of these subpopulations, is needed.

  • PDF

Quantitative Differences between X-Ray CT-Based and $^{137}Cs$-Based Attenuation Correction in Philips Gemini PET/CT (GEMINI PET/CT의 X-ray CT, $^{137}Cs$ 기반 511 keV 광자 감쇠계수의 정량적 차이)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Park, Eun-Kyung;Kim, Jong-Hyo;Kim, Jae-Il;Lee, Hong-Jae;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.182-190
    • /
    • 2005
  • Purpose: There are differences between Standard Uptake Value (SUV) of CT attenuation corrected PET and that of $^{137}Cs$. Since various causes lead to difference of SUV, it is important to know what is the cause of these difference. Since only the X-ray CT and $^{137}Cs$ transmission data are used for the attenuation correction, in Philips GEMINI PET/CT scanner, proper transformation of these data into usable attenuation coefficients for 511 keV photon has to be ascertained. The aim of this study was to evaluate the accuracy in the CT measurement and compare the CT and $^{137}Cs$-based attenuation correction in this scanner. Methods: For all the experiments, CT was set to 40 keV (120 kVp) and 50 mAs. To evaluate the accuracy of the CT measurement, CT performance phantom was scanned and Hounsfield units (HU) for those regions were compared to the true values. For the comparison of CT and $^{137}Cs$-based attenuation corrections, transmission scans of the elliptical lung-spine-body phantom and electron density CT phantom composed of various components, such as water, bone, brain and adipose, were performed using CT and $^{137}Cs$. Transformed attenuation coefficients from these data were compared to each other and true 511 keV attenuation coefficient acquired using $^{68}Ge$ and ECAT EXACT 47 scanner. In addition, CT and $^{137}Cs$-derived attenuation coefficients and SUV values for $^{18}F$-FDG measured from the regions with normal and pathological uptake in patients' data were also compared. Results: HU of all the regions in CT performance phantom measured using GEMINI PET/CT were equivalent to the known true values. CT based attenuation coefficients were lower than those of $^{68}Ge$ about 10% in bony region of NEMA ECT phantom. Attenuation coefficients derived from $^{137}Cs$ data was slightly higher than those from CT data also in the images of electron density CT phantom and patients' body with electron density. However, the SUV values in attenuation corrected images using $^{137}Cs$ were lower than images corrected using CT. Percent difference between SUV values was about 15%. Conclusion: Although the HU measured using this scanner was accurate, accuracy in the conversion from CT data into the 511 keV attenuation coefficients was limited in the bony region. Discrepancy in the transformed attenuation coefficients and SUV values between CT and $^{137}Cs$-based data shown in this study suggests that further optimization of various parameters in data acquisition and processing would be necessary for this scanner.