• Title/Summary/Keyword: Normal Transmission

Search Result 598, Processing Time 0.022 seconds

Production of Mycoplasma-Free Jujube Trees through In vitro Micrografting (기내미세접목(器內微細接木)에 의(依)한 대추나무의 마이코플라즈마 무병주(無病株) 생산(生産))

  • Park, Jae In
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.3
    • /
    • pp.254-259
    • /
    • 1993
  • For the production of mycoplasma-free jujube trees from mycoplasma-infected trees in vitro micrografting visas carried out using apical meristems of in vitro grown plantlets as scions. The rootstocks were hypocotyl segments of in vitro germinated seedlings of Zizyphus jujuba Mill. which is widely used as rootstocks in the field grafting. Ten percent of scions showed normal growth and grew into plants. The presence of mycoplasma was tested using transmission electron microscopy and fluorescence microscopy. Mycoplasma was not found in the tissues of scion parts and seedlings, whereas it was found in in vitro grown plantlets. This suggests that the production of mycoplasmaa-free jujube trees is possible by the in vitro micrografting technique.

  • PDF

Improvement of ESD (Electrostatic Discharge) Protection Performance of NEDSCR (N-Type Extended Drain Silicon Controlled Rectifier) Device using CPS (Counter Pocket Source) Ion Implantation (CPS 이온주입을 통한 NEDSCR 소자의 정전기 보호 성능 개선)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.1
    • /
    • pp.45-53
    • /
    • 2013
  • An electrostatic discharge (ESD) protection device, so called, N-type extended drain silicon controlled rectifier (NEDSCR) device, was analyzed for high voltage I/O applications. A conventional NEDSCR device shows typical SCR-like characteristics with extremely low snapback holding voltage. This may cause latch-up problem during normal operation. However, a modified NEDSCR device with proper junction/channel engineering using counter pocket source (CPS) ion implantation demonstrates itself with both the excellent ESD protection performance and the high latch-up immunity. Since the CPS implant technique does not change avalanche breakdown voltage, this methodology does not reduce available operation voltage and is applicable regardless of the operation voltage.

Effect of the Nasal Cavity Resonance on the Acoustic Characteristics of Korean Vowels (비강 공명이 한국어 모음에 미치는 음향학적 영향)

  • 성명훈;오승하;강명구;고태용;김광현;김진영
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.4 no.1
    • /
    • pp.24-32
    • /
    • 1991
  • Cleft palate or velopharyngeal incompetence shows many disorders and disabilities affecting speech transmission. including distortion. substitution. and the nasalization of the vowels. The nasalized vowels are produced primarily by lowering of the velum. resulting in opening a side passage for the air flow through the nasal cavity. These abnormal movements give rise to complex modification of the physical property of the sound or in the sound spectrum. The authors employed Sonagraph$^{\circledR}$ as a sound analyzer in order to ascertain the features which characterize the nasalization of vowels. Twenty healthy Korean male adult voluteers were analyzed in artificial conditions of anterior and posterior nasal obstruction. and velo-pharyngeal incompetence. The results were as follows : 1) Fundamental frequency was not changed by nasal obstruction or velopharyngeal incompetence. 2) There was no significant difference of the formant intensity between normal and nasal vowels. 3) In VPI, a decrease of the frequency of $F_2$ was observed in /e/ and /i/ vowels(p<0.001). 4) In VPI, the $F_2$ was frequently missed in /o/ and /u/ vowels. 5) In the consonant spectra of VPI, the 'release burst' was usually not observed.

  • PDF

A Hybrid Boundary Integral Equation Model Applied for the Calculation of Normal Incident Waves (혼합경계적분 요소법을 사용한 직교입사파랑의 반사률계산 모델)

  • 서승남;김상익
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.3
    • /
    • pp.170-175
    • /
    • 1991
  • In order to calculate reflection coefficients of surface waves due to underwater obstacles, the hybrid boundary integral equation method is used. Numerical results based on the linear element are verified to the exact solutions for a flat bottom. Reflection coefficient and transmission coefficients for a step are compared to Young's results and the results by EFEM (Kirby et al., 1987), in which reflection coefficients decrease to zero as the periods of incident waves decrease. Reflection coefficients for a sinusiodal hump located on a constant depth increase due to the interaction between humps.

  • PDF

Morphological Evidence for the Transport of Dehydrocholic Acid in the Hepatocyte as Revealed by Freeze Fracture Replica (급속동결할단법에 의한 간세포내 Dehydrocholic Acid 수송에 관한 형태학적 관찰)

  • Shin, Young-Chul
    • Applied Microscopy
    • /
    • v.28 no.1
    • /
    • pp.83-90
    • /
    • 1998
  • The pathway of intracellular transport of dehydrocholic acid was investigated in the hepatocytes of rats by transmission electron microscopy with conventional and freeze fracture methods. Both in normal and experimental groups, the cis Golgi cisterns were sacculated and faces toward the bile canaliculus. In the experimental group, however, the cis Golgi cisterns showed buds, which were probably separated to be vesicles. Some of the buds were connected to the cisterns with the narrow neck. The vesicles were increased in the vicinity of bile canaliculi. The fusion between vesicles and bile canaliculus were frequently observed in the experimental group. This was particularly well shown in the freeze fracture replica. In the thin section, the vesicles were devoid of visible contents as seen in the bile canaliculli. The evidence suggests that the vesicles are derived from the cis Gogi cistern in the way that buds pinch off, serve as vehicles to transport dehydrocholic acids and fuse to bile canaliculi for exocytosis.

  • PDF

Detection and Parameter Estimation for Jitterbug Covert Channel Based on Coefficient of Variation

  • Wang, Hao;Liu, Guangjie;Zhai, Jiangtao;Dai, Yuewei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1927-1943
    • /
    • 2016
  • Jitterbug is a passive network covert timing channel supplying reliable stealthy transmission. It is also the basic manner of some improved covert timing channels designed for higher undetectability. The existing entropy-based detection scheme based on training sample binning may suffer from model mismatching, which results in detection performance deterioration. In this paper, a new detection method based on the feature of Jitterbug covert channel traffic is proposed. A fixed binning strategy without training samples is used to obtain bins distribution feature. Coefficient of variation (CV) is calculated for several sets of selected bins and the weighted mean is used to calculate the final CV value to distinguish Jitterbug from normal traffic. Furthermore, the timing window parameter of Jitterbug is estimated based on the detected traffic. Experimental results show that the proposed detection method can achieve high detection performance even with interference of network jitter, and the parameter estimation method can provide accurate values after accumulating plenty of detected samples.

Calculation Method of Modification Factors for Fault Location Algorithm Using Boosting Current of Operating Electric Train in AT Feeding System (AT급전계통에서 실제 운행 중인 전기기관차 부하를 이용한 고장점 표정 알고리즘 보정계수 산출 방법)

  • Kim, Cheol-Hwan;Kim, Sung-Ryul;Kwon, Sung-Il;Cho, Gyu-Jung;Kim, Chul-Hwan;Song, In-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.504-510
    • /
    • 2016
  • In general, a fault locator is installed in Sub-Station of AT(Auto-transformer) feeding system to estimate the fault location and to protect the Korean AT feeding system. Since the line impedance characteristic is different to normal 3-phase transmission line, we need particular modification factors, which can be calculated using fault location recording data, to estimate the accurate fault location. Up to recently, forcible ground test has been used to calculate the modification factors of the fault locator. However, large amount of current is occurred when the forcible ground test is performed, and this current affects to adjacent equipments. Therefore, we proposed a novel calculation method of modification factors, arbitrary trip test, using boosting current of the operating electric train. Through several field test, we confirmed that modification factors for fault locator can be easily calculated by using proposed method. Moreover, we verified the accuracy and stability of the proposed calculation method.

A Study on the Improvement of Bayesian networks in e-Trade (전자무역의 베이지안 네트워크 개선방안에 관한 연구)

  • Jeong, Boon-Do
    • International Commerce and Information Review
    • /
    • v.9 no.3
    • /
    • pp.305-320
    • /
    • 2007
  • With expanded use of B2B(between enterprises), B2G(between enterprises and government) and EDI(Electronic Data Interchange), and increased amount of available network information and information protection threat, as it was judged that security can not be perfectly assured only with security technology such as electronic signature/authorization and access control, Bayesian networks have been developed for protection of information. Therefore, this study speculates Bayesian networks system, centering on ERP(Enterprise Resource Planning). The Bayesian networks system is one of the methods to resolve uncertainty in electronic data interchange and is applied to overcome uncertainty of abnormal invasion detection in ERP. Bayesian networks are applied to construct profiling for system call and network data, and simulate against abnormal invasion detection. The host-based abnormal invasion detection system in electronic trade analyses system call, applies Bayesian probability values, and constructs normal behavior profile to detect abnormal behaviors. This study assumes before and after of delivery behavior of the electronic document through Bayesian probability value and expresses before and after of the delivery behavior or events based on Bayesian networks. Therefore, profiling process using Bayesian networks can be applied for abnormal invasion detection based on host and network. In respect to transmission and reception of electronic documents, we need further studies on standards that classify abnormal invasion of various patterns in ERP and evaluate them by Bayesian probability values, and on classification of B2B invasion pattern genealogy to effectively detect deformed abnormal invasion patterns.

  • PDF

HPA MMIC to W/G Antenna Transition Loss Analysis and Development Results of W-band Transmitter Module

  • Kim, Wansik;Jung, Juyong;Lee, Juyoung;Kim, Jongpil
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.236-241
    • /
    • 2019
  • This paper will read about a multichannel frequency-modulated continuous wave (FMCW) radar sensor with switching transmit (TX) antennas is developed at W-band. To achieve a high angular resolution, a uniform linear array consisting of 5 switching-TX and 12 receive (RX) antennas is employed with the digital beamforming technique. The overall radar front-end module comprises a W-band transceiver and TX/RX antennas. A multichannel transceiver module consists of 5 up-conversion and 12 down-conversion channels, where one of the TX channels is sequentially switched ON. For developing transmitter, we developed an HPA (high power amplified) MMIC chip for W-band radar system and fabricated a transmitter module using this chip. In order to develop the W-band transmitter, we analyzed the important antenna transition structure from HPA MMIC line to W/G (Waveguide)antenna via M/S(microstrip) and fabricated it with 5 transmission channels. As a result, the output power of the transmitter was within 1 dB of the error range after analysis and measurement under normal temperature and environmental conditions.

Comparative Study of the Behavior of a Wind Farm Integrating Three Different FACTS Devices

  • Sarrias, Raul;Gonzalez, Carlos;Fernandez, Luis M.;Garcia, Carlos Andres;Jurado, Francisco
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1258-1268
    • /
    • 2014
  • Improving grid connection of wind farms is a relevant issue to be addressed, especially for fixed-speed wind turbines. Certain elements, such as FACTS (Flexible AC Transmission Systems), are able to perform voltage and reactive power regulation in order to support voltage stability of wind farms, and compensate reactive power consumption from the grid. Several devices are grouped under the name of FACTS, which embrace different technologies and operating principles. Here, three of them are evaluated and compared, namely STATCOM (Static Synchronous Compensator), SVC (Static Var Compensator) and SSSC (Static Synchronous Series Compensator). They have been modeled in MATLAB/Simulink, and simulated under various scenarios, regarding both normal operation and grid fault conditions. Their response is studied together with the case when no FACTS are implemented. Results show that SSSC improves the voltage stability of the wind farm, whereas STATCOM and SVC provide additional reactive power.