• 제목/요약/키워드: Normal Condition

검색결과 3,198건 처리시간 0.039초

Some Notes on Lp-metric Space of Fuzzy Sets

  • Kim, Yun-Kyong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제10권3호
    • /
    • pp.242-246
    • /
    • 2010
  • It is well-known that the space $E^n$ of fuzzy numbers(i.e., normal, upper-semicontinuous, compact-supported and convex fuzzy subsets)in the n-dimensional Euclidean space $R^n$ is separable but not complete with respect to the $L_p$-metric. In this paper, we introduce the space $F_p(R^n)$ that is separable and complete with respect to the $L_p$-metric. This will be accomplished by assuming p-th mean bounded condition instead of compact-supported condition and by removing convex condition.

표면거칠기와 유한요소법을 이용한 터빈 블레이드의 파손해석에 관한 연구 (A Study on Failure Analysis of Turbine Blade Using Surface Roughness and FEM)

  • 홍순혁;이동우;이선봉;조석수;주원식
    • 한국자동차공학회논문집
    • /
    • 제9권6호
    • /
    • pp.170-177
    • /
    • 2001
  • Turbine blade is subject to torsional load by torsion-mount, centrifugal load by rotation of rotor and repeated bending load by steam pressure. Turbine with partially cracked blade has normal working condition at initial repair time but vibratory working condition at middle repair time due to crack growth. Finite element analysis on turbine blade indicates that repeated bending load out of all loads is the most important factor on fatigue strength of turbine blade. Therefore, this study shows root mean square roughness has linear relation with stress intensity factor range in 12% Cr steel and can predict loading condition of fractured turbine blade.

  • PDF

Diamond 공구에 의한 aluminium 합금의 초정밀 절삭가공에 관한 연구 (A Study on the Ultraprecision Cutting of Aluminium Alloy by the Diamond Tool)

  • 유기현;문상돈;유종선;김태영;서남섭
    • 한국정밀공학회지
    • /
    • 제13권1호
    • /
    • pp.78-83
    • /
    • 1996
  • This paper presents the characteristics of surface roughness and cutting force in ultraprecision cutting of aluminium alloy using natural diamond tools whose edge radii are smaller than those of tools made of other materials. The feed rate and depth of engagement were set to be a micrometer order. After measuring the surface roughness of machined surface and cutting force for each cutting condition, the relations between the surface quality and its condition were investigated qualitatively. If the feed rate was under a certain limit, the machined surface quality was deteriorated unexpectedly. This is supposed to have happened due to vibration leading its condition to abnormal one. In a certain situation the machined surface roughness by a natural diamond tool was inferior to that made by a carbide tool whose cutting edge radius is larger. This is supposed to be caused by not normal machining but burnishing effect.

  • PDF

견직물의 고온고압일욕 정련염색에 관한 연구 (A Study on the Degumming and Dyeing of Silk Fabric in One Bath under the High Temperature and High Pressure)

  • 안경조
    • 한국의류학회지
    • /
    • 제12권2호
    • /
    • pp.133-144
    • /
    • 1988
  • Silk fabrics were degummed and dyed in one bath under the condition of high temperature and high pressure and the results obtained were summerized as follows. 1. The degumming ratio is nearly the same as that of two bath method under the normal condition and the optimal condition is for 30 minutes at $120^{\circ}C$. 2. The dyeing absorption ratio is a little lower than that of two bath method. 3. The tensile strength and elongation are hardly shown the difference between two methods. 4. The fastness of the dyed fabric of one bath method is a little better than that of two bath method. (light, washing, rubbing) 5. The stiffness of the silk fabric treated by one bath method is a little harshier compare to that of two bath method.

  • PDF

초음파술에 의한 더러브렛 암말의 번식환경이 임신에 미치는 영향 (Effects on Pregnancy of Reproductive Environments by Ultrasonography in Thoroughbred Mares)

  • 양영진;조길재;신상태;남치주
    • 한국임상수의학회지
    • /
    • 제20권1호
    • /
    • pp.121-130
    • /
    • 2003
  • The purpose of this study was to investigate the effect of breeding conditions on reproductive efficiency of thoroughbred broodmares by ultrasonography. The mean age and breeding career of 120 mares used in this study were 11 years old and 6 years, respectively. The average pregnancy rate and embryonic loss rate were 87.5%, 11.8%. The groups that were 8-10 years old, 4-6 years, maiden and mated on May showed the highest pregnancy rate. While mares mated on 1st estrus post partus had the highest ovulation rate but showed the highest embryonic loss rate and he lowest pregnancy rate. And broodmares that had more intrauterine foreign bodies such as cyst and fluid with age and breeding career had represented lower pregnancy rate and higher embryonic loss rate than those having normal uterine condition. These results suggest that the breeding condition and uterine environment of mares had a significant influence on reproductive efficiency.

배전설비의 온라인 모니터링과 진단 기술 동향 (A Technical Trend on On-Line Condition Monitoring and Diagnostics of Power Equipments)

  • 임완수;이태우;여운철;이성길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1974-1975
    • /
    • 2007
  • Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system. The paper presents the results of wireless temperature monitoring of switchgear at a power plant over a two-year period.

  • PDF

AE 원신호 파형분석에 의한 에어컨 컴프레서의 상태 진단 (Condition Diagnosis of Air-conditioner Compressor by Waveform Analysis of AE Raw Signal)

  • 이감규;강익수;강명창;김정석
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.125-129
    • /
    • 2004
  • For the diagnosis of compressor abnormal condition in air-conditioner, AE signal which is derived from wear condition, compressed air and assembly error is analyzed experimentally. The burst and continuous type AE signal occurred by metal contact and compressed air and AE raw signal of compressors were directly acquired in production line. After extracting samples according to waveforms, Early Life Test(ELT) is conducted and classified to normal and abnormal waveform. The efficient parameters of waveform pattern are investigated in time and frequency domain and the diagnosis algorithm of air-conditioner by Neural Network estimation is suggested.

TIME ANALYTICITY FOR THE HEAT EQUATION UNDER BAKRY-ÉMERY RICCI CURVATURE CONDITION

  • Ling Wu
    • 대한수학회보
    • /
    • 제60권6호
    • /
    • pp.1673-1685
    • /
    • 2023
  • Inspired by Hongjie Dong and Qi S. Zhang's article [3], we find that the analyticity in time for a smooth solution of the heat equation with exponential quadratic growth in the space variable can be extended to any complete noncompact Riemannian manifolds with Bakry-Émery Ricci curvature bounded below and the potential function being of at most quadratic growth. Therefore, our result holds on all gradient Ricci solitons. As a corollary, we give a necessary and sufficient condition on the solvability of the backward heat equation in a class of functions with the similar growth condition. In addition, we also consider the solution in certain Lp spaces with p ∈ [2, +∞) and prove its analyticity with respect to time.

주행 경로의 가혹도에 따른 소형 경유 자동차의 배출 특성 분석에 관한 연구 (A Study on the Analysis of Emission Characteristics for Light-duty Diesel Vehicle According to the Severity of the Test Route)

  • 오상기;전영재;차준표
    • 한국분무공학회지
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2024
  • The EU (European Union) was introduced Euro-6e in 2023. Recently, the EU prepare to introduce Euro-7. One of difference Euro-6e and Euro-7 is test route condition. This study developed 5 test routes that have different characteristics and severity. The severity of test routes was made by traffic and road gradient. And this study was conducted RDE test on 5 test routes for Light-Duty diesel vehicle (Euro-6d). Based on the test results, the emission characteristics of CO2 and NOx were analyzed according to the severity of the test routes. Especially, 4 test routes were satisfied normal driving condition of Euro-7 and other test route was satisfied extended driving condition of Euro-7.

Implementation of the F-B function comparison on the body movement

  • Kim, Jeong-Lae;Hwang, Kyu-Sung;Nam, Yong-Seok
    • International journal of advanced smart convergence
    • /
    • 제3권1호
    • /
    • pp.20-24
    • /
    • 2014
  • To compare body signal, was designed the F-B function system on the body movement for the comfortable state. To detect subject of the normal state, was decided on the base of physical signal in the body movement. There are to detect the condition of Vision, Vestibular, Somatosensory and CNS. Vision condition was verified a variation of greater average (Vi-${\Phi}_{AVG-AVG}$) was presented slightly greater at $17.424{\pm}9.65$ unit. Vestibular condition was identified a variation of slightly greater average (Ve-${\Phi}_{AVG-AVG}$) was presented at $9.068{\pm}1.478$ unit. Somatosensory condition was checked a variation of smaller average (So-${\Phi}_{AVG-AVG}$) was presented slightly smaller at $2.79{\pm}0.419$ unit. CNS condition was confirmed a variation of diminutive smaller average (C-${\Phi}_{AVG-AVG}$) was presented slightly larger at $0.557{\pm}0.153$ unit. As the model depends on the F-B function system of body movement, average values of these perturbation were computed F-B function comparison data. These systems will be to infer a data algorithm and a data signal processing system for the evaluation of the stability.