• Title/Summary/Keyword: Normal Condition

Search Result 3,204, Processing Time 0.026 seconds

SOLVING A CLASS OF GENERALIZED SEMI-INFINITE PROGRAMMING VIA AUGMENTED LAGRANGIANS

  • Zhang, Haiyan;Liu, Fang;Wang, Changyu
    • Journal of applied mathematics & informatics
    • /
    • v.27 no.1_2
    • /
    • pp.365-374
    • /
    • 2009
  • Under certain conditions, we use augmented Lagrangians to transform a class of generalized semi-infinite min-max problems into common semi-infinite min-max problems, with the same set of local and global solutions. We give two conditions for the transformation. One is a necessary and sufficient condition, the other is a sufficient condition which can be verified easily in practice. From the transformation, we obtain a new first-order optimality condition for this class of generalized semi-infinite min-max problems.

  • PDF

A Study on the Wear Detection of a Milling Using the Wavelet Transform (웨이브렛 변환을 이용한 밀링 공구의 마모 감지 연구)

  • Jeon, Do-Young;Lee, Gun;Kim, Kyoung-Ho
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.211-214
    • /
    • 2002
  • The detection of tool wear is very important in an automated manufacturing system. This paper presents a tool condition monitoring system based on the wavelet transform analysis of the AC servo motor current in a milling process. The current measurement is relatively simple and does not affect machining operations. The discrete wavelet transform was used to decompose the current of a spindle AC servo motor in the time and frequency domain. The feature vectors were extracted from the decomposed signals and compared to clarity normal and wear conditions. The results show the feasibility of the wavelet transform analysis for the tool condition monitoring.

  • PDF

Independence Condition in the Repeated Randomized Response Models (반복시행된 확률화 응답(RRD) 모형의 독립조건)

  • Lee Kwan J.;Kook Sejeong
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2000.11a
    • /
    • pp.33-38
    • /
    • 2000
  • Krishnamoorphy and Raghavarao(1993) invented exact binomial and asymptotically normal test procedures for truthful answering in the repeated randomized response models under the assumption that two repeated response measures are independent. Under the same assumption, Lakshmi and Raghavarao(1992) suggested asymptotic chi-square test for respondents' truthful answering in the same models. In this article we detect the factors and the conditions with which two response variables might be independent, and find the condition for independence in the repeated randomized response models with considering untruthful answer. But, the condition of independence make the randomized model no meaning. Under the assumption of conditional independence between two response variables, we can apply the same logical statements on deriving the tests for truthful answering in the repeated randomized response models as in Krishnamoorphy and Raghavarao(1993).

  • PDF

Predictive control based partial switching PFC converter for achieving high efficiency (고효율 구현을 위한 예측제어 기반 부분 스위칭 PFC 컨버터)

  • Choi, Yeong-Jun;Kim, Tae-Jin;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.1-2
    • /
    • 2014
  • In this paper the partial switching PFC converter which is based on predictive control is proposed. In terms of satisfying the harmonic standard, the predictive control shows a similar performance to the conventional average current mode control PFC in the normal input condition. Moreover, the current harmonic characteristic is insensitive to the distorted input voltage. With predictive control method, novel on-line partial switching strategy is suggested in this paper. Depending on the operating condition, the partial switching PFC converter can boost its output voltage. Also when its efficiency needs to be improved, according to load condition, the partial switching can be achieved. The proposed strategy is proved by the results of FFT and the loss analysis using PSIM 9.0.

  • PDF

Tool Monitoring of a CNC Machining Center Using Te Wavelet Transform (웨이브렛 변환을 이용한 CNC 공작기계의 툴 모니터링)

  • 서동욱;김도현;전도영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.148-152
    • /
    • 2000
  • Detection of tool wear is very important in automated manufacturing. This paper presents tool condition monitoring system based on the wavelet analysis of the AC servo motro current in drilling and milling process. The current measurement system is relatively simple and its mounting will not affect machining operations. The discrete wavelet transform was used to decompose the current signal of a spindle AC servo motor in time - frequency domain. The feature vectors were extracted from the decomposed signals and compared for normal and wear condition. The results show the possibility for the effective application of wavelet analysis to tool condition monitoring.

  • PDF

Experiments on Mechanical Characteristics of Anti-Washout Concrete with Mixing and Placing Condition (배합 및 타설조건에 따른 수중불분리성 콘크리트의 역학적특성 변화에 관한 실험)

  • Yang, Eun-Ik;Choi, Hong-Shik;Heo, Gweon;Lee, Si-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.141-146
    • /
    • 1999
  • An experimental study is carried out to estimate the effects of mixing and placing condition on the mechanical properties of anti-washout concrete. According to the test results, mixing method and placing temperature do affect the characteristics of rrsh concrete, while they do not affect the strength development of anti-washout concrete. But, concrete strength was greatly affected by the placing condition and placing height. Concrete strength decreases linearly as the placing height increased. Compared to the normal concrete, the increase in strength is not associated much with an increase in the elastic modulus of anti-washout concrete.

  • PDF

Modeling of Remediation Design in Theoretically Heterogeneous Domain

  • Ko, Nak-Youl;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.302-306
    • /
    • 2004
  • Probabilistic approaches are applied to the problem of groundwater remediation design to consider the risk of design and heterogeneity of real condition. Hydraulic conductivity fields are generated by two methods. First, the homogeneous domains which have the hydraulic conductivity with log-normal distribution are constructed by using Latin Hypercube method. Second, random fields with a certain spatial correlation are also generated. The optimal solutions represented by cumulative distribution function (CDF) of relative cost are calculated by three different manners. The one uses the homogeneous domains with the optimal design of base condition. It shows that ver)'wide range of cost and the influences of different penalty values. The other one uses the random field with same design and shows narrow range of cost. These CDF can reflect on the risk of optimal solution in a simple exampie condition and be effective in estimating the cost of groundwater remediation.

  • PDF

A Study on Pressure Distributions in a Centrifugal Compressor Channel Diffuser (원심압축기 채널디퓨저 내부의 압력분포에 관한 연구)

  • Gang, Jeong-Sik;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.507-513
    • /
    • 2001
  • Time averaged pressure distributions in a high-speed centrifugal compressor channel diffuser at design and off-design flow rates are investigated. Pressure distributions from the impeller exit to the channel diffuser exit are measured for various flow rates from choke to near surge condition, and the effects of operating condition are discussed. The strong non-uniformity in the pressure distribution is obtained over the vaneless space and semi-vaneless space caused by the impeller-diffuser interaction. As the flow rate increases, flow separation near the throat, due to large incidence angle at the vane leading edge, increases aerodynamic blockage and reduces the aerodynamic flow area downstream. Thus the minimum pressure location occurs downstream of the geometric throat, and it is named as the aerodynamic throat. And at choke condition, normal shock occurs downstream of this aerodynamic throat. The variation in the location of the aerodynamic throat is discussed.

A Study on Fracture Mechanism of Torsion-Mounted Type Turbine Blade (비틀림 마운트형 터빈 블레이드의 파괴기구에 관한 연구)

  • Hong, Soon-Hyeok;Lee, Dong-Woo;Jang, Deuk-Yul;Cho, Seoks-Woo;Joo, Won-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.585-590
    • /
    • 2001
  • Turbine blade is subject to torsional load by torsion-mount, centrifugal load by rotation of rotor and repeated bending load by steam pressure. Turbine with partially cracked blade has normal working condition at initial repair time but vibratory working condition at middle repair time due to crack growth. Finite element analysis on turbine blade indicates that repeated bending load out of all loads is the most important factor on fatigue strength of turbine blade. Therefore, this study shows root mean square roughness has linear relation with stress intensity factor range in 12% Cr steel and can predict loading condition of fractured turbine blade.

  • PDF

Properties of On-Line Partial Discharge in Hydrogenerator Stator Windings (수력발전기 고정자 권선의 운전중 부분방전 특성)

  • Kim, Byong-Han;Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.172-177
    • /
    • 2006
  • During normal machine operation, partial discharge(PD) tests were performed with partial discharge analyzer(PDA) in two hydrogenerators. Six cable couplers were installed in circuit ring bus and endwinding of three phases. PDA showed that the normalized quantity number(NQN) and the partial discharge magnitude$(Q_m)$ were very low in hydrogenerator #1 and #2, respectively. The trend analyses of NQN and $Q_m$ value are available for monitoring of the insulation condition in hydrogenerator stator windings. The insulation condition of stator winding can be assessed. Discharge at conductor surface was discovered in B phase(C2 coupler) of hydrogenerator #1. Internal discharges were generated in A and C phases(C2 coupler) of hydrogenerator #1 and in A, Band C phases(C1 and C2 couplers) of hydrogenerator #2. Slot discharges occurred in A, Band C phases(C1 coupler) of hydrogenerator #1. The stator windings of two hydrogenerators were in good condition.