• 제목/요약/키워드: Normal Condition

검색결과 3,198건 처리시간 0.035초

통계적모델을 이용한 원자로냉각재펌프 밀봉장치 성능감시 (Reactor Coolant Pump Seal Monitoring System Using Statistical Modeling Techniques)

  • 이송규;정장규;배종길;안상하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1386-1390
    • /
    • 2007
  • This paper presents the equipment condition monitoring technology for the process or the equipment using statistical techniques. The equipment condition monitoring system consists of an empirical model to estimate the expected sensor values of process variables and a diagnose model to detect the abnormal condition and to identify the root source of the problem. The empirical model is constructed by the analysis of historic data. The diagnose model uses the sequential probability ratio test (SPRT) technique. The monitoring system was tested with real operating data acquired from the Reactor Coolant Pump Seal in the Nuclear Power Plant. It can detect the system degradation or failure at the early stage since it is able to catch the subtle deviation of process variables from normal condition.

  • PDF

Detection and Classification of Bearing Flaking Defects by Using Kullback Discrimination Information (KDI)

  • Kim, Tae-Gu;Takabumi Fukuda;Hisaji Shimizu
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.28-35
    • /
    • 2002
  • Kullback Discrimination Information (KDI) is one of the pattern recognition methods. KDI defined as a measure of the mutual dissimilarity computed between two time series was studied for detection and classification of bearing flaking on outer-race and inner-races. To model the damages, the bearings in normal condition, outer-race flaking condition and inner-races flaking condition were provided. The vibration sensor was attached by the bearing housing. This produced the total 25 pieces of data each condition, and we chose the standard data and measure of distance between standard and tested data. It is difficult to detect the flaking because similar pulses come out when balls pass the defection point. The detection and classification method for inner and outer races are defected by KDI and nearest neighbor classification rule is proposed and its high performance is also shown.

드럼세탁기 화재안전성 확보를 위한 실험연구 (A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine)

  • 홍성호;이상현;박상태;유현종;전웅재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

전기히터의 화재위험성에 관한 실험연구 (An Experimental Study on the Fire Hazards in Electric Heater)

  • 홍성호;이복영;박상태;유현종
    • 한국안전학회지
    • /
    • 제22권2호
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.

과부하상태의 변동을 고려한 디지털보호계전기의 최적보호알고리즘 연구 (A Study of the Best Suited Algorithm for Digital Protection Relay in Fluctuated Overload Condition)

  • 이창호;백영식;김병진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.21-23
    • /
    • 2005
  • Recently, in power system, even though the needs of digital protection relay are highly increased, there are some problem in the field during apply digital protection relay. When the relay are in the fluctuated overload condition, existing algorithm calculate the trip time only with the measured current of just previous stage, and when the load current fluctuate between overload and normal condition, existing algorithm sometimes dose not make the relay trip. This thesis will study about these kinds of existing algorithm problem in digital protection relay, and will suggest the best suited algorithm for digital protection relay in fluctuated overload condition.

  • PDF

Bicubic Patch체 의한 보간곡면의 모델링 및 가공에 관한 연구

  • 이진모;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.1025-1030
    • /
    • 1997
  • In this study,the procedure of interpolation surface modeling on bicubic spline patch equation and NC machining are presented. The procedure consists of three parts : patch modeling,cutter location data generation,post processing and NC milling machining. For generation of the cutter location data,tangent vectors and units normal vectors on the patch must be calculated. In order to investigate the properties of the interpolation surface created by bicubic spline patch, two kinds of end conditions, clamped end condition and relaxed end condition,were applied in this study. The shape of the patch depends on the magnitide of the tangent vectors and twist vectors at the corners of bicubic surface patch. the patch generated by relaxed end condition more approximated to the surface patch which was given.

  • PDF

V련 현수애자장치의 횡진특성과 실선로 적용 (A Swing Characteristics and Application Condition of the V type Suspension String Set)

  • 손홍관;이형권;금의연;민병욱;최진성;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.627-629
    • /
    • 2004
  • V type suspension string sets prevent instabilities from swing motion by the horizontal angle and by wind pressure. These installation conditions are controled mainly 3 items - normal swing angle by horizontal angle of line, unusual swing angle by strong wind, minimum vertical loads. We calculated and analysed that factors for the 765kV transmission line condition. And we were tested swing characteristics of V-string sets in real size test situation. So, we find to installation condition for the V type suspension string sets. This results will be used to design of V type suspension string set and to decision of the installation condition.

  • PDF

연장급전 전압강하 계산을 위한 전기철도 급전 시뮬레이터의 검증에 관한 연구 (A Study on Verification of PowerRail based on Voltage Drop under Extended Feeding Condition)

  • 김주락
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.331-337
    • /
    • 2015
  • The power flow analysis of electrified railway is required complicated calculation, because of variable load. Train runs trough rail supplied by electric power therefore, the load value in electrified railway system fluctuates along time. The power flow algorithm in electrified railway system is different from general power system, and the power flow simulation is peformed by the particular simulation software. Powerail is simulation software for analysis of traction power supply system developed by KRRI, in 2008. This consists of load forecasting module, including TPS and time scheduling, and power flow module. This software was verified by measured current under normal feeding condition, however, has not been verified by voltage on the condition of extended feeding. This paper presents the verification of PowerRail based on voltage drop under extended feeding condition. This is performed by comparing simulation result with field test. Field test and simulation is done in commercial railway line.

건조일체형 드럼세탁기의 화재위험성에 관한 실험연구 (A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine)

  • 홍성호
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

설계 및 탈설계점에서의 원심압축기 채널디퓨저 내부의 압력분포에 관한 연구 (A Study on the Pressure Distribution in the Centrifugal Compressor Channel Diffuser at Design and Off-Design Conditions)

  • 강정식;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.548-554
    • /
    • 2000
  • The aim of this paper is to understand the time averaged pressure distributions in a high-speed centrifugal compressor channel diffuser at design and off-design flow rates. Pressure distributions from the impeller exit to the channel diffuser exit are measured and discussed far various flow rates from choke to near surge condition, and the effect of operating condition is discussed. The strong non-uniformity in the pressure distribution is obtained over the vaneless space and semi-vaneless space caused by the impeller-diffuser interaction. As the flow rate increases, flow separation near the throat, due to large incidence angle at the vane leading edge, increases aerodynamic blockage and reduces the aerodynamic flow area downstream. Thus the minimum pressure location occurs downstream of the geometric throat, and it is named as the aerodynamic throat. And at choke condition, normal shock occurs downstream of this aerodynamic throat. The variation in the location of the aerodynamic throat is discussed.

  • PDF