• 제목/요약/키워드: Nonlinear wave force

검색결과 92건 처리시간 0.022초

안벽에 계류된 선박의 비선형 운동응답 (Nonlinear Motion Responses of a Moored Ship beside Quay)

  • 이호영;임춘규;유재문;전인식
    • 한국해양공학회지
    • /
    • 제17권4호
    • /
    • pp.8-15
    • /
    • 2003
  • When a typoon sets into harbour, a moored ship shows erratic motions and even mooring line failure may occur. such troubles may be caused by harbour resonance phenomena, resulting in large motion amplitudes at low frequency, which is close ti the natural frequency of th moored ship. The nonlinear motions of a ship moored to quay are simulated under external forces due to wave, current including mooring forces in time domain. The forces due to waves are obtained from source and dipole distribution method in the frequency domain. The current forces are calculated by using slow motion maneuvering equation in the horizontal plane. The wind forces are calculated from the empirical formula of ABS and the mooring forces of ropes and fenders are modeled as linear spring.

불규칙파에 대한 고정해양구조물의 동적해석 (Dynamic Analysis of Fixed Offshore Structures Subjected to Random Waves)

  • 윤정방;최정호;류정수
    • 대한토목학회논문집
    • /
    • 제5권2호
    • /
    • pp.1-9
    • /
    • 1985
  • 본 논문에서는 해저석유개발에 사용되는 고정해양구조물의 불규칙파랑하중에 대한 해적기법으로 주파수영역해법과 시간영역해법에 대하여 연구하였다. 주파수영역해법에서는 파동의 비선형 점성저항력을 선형화한 후 파고스펙트럼으로부터 구조물의 응답스펙트럼을 구하였으며, 시간영역해법에서는 불규칙파의 유동속도와 가속도의 시계열을 파고스펙트럼으로부터 Monte Carlo 기법으로 시뮬레이션한 후 이를 이용하여 구조물의 거동을 해석하였다. 수심이 다른 지점에 설치된 2개의 구조물을 예로 택하여, 여러 가지 파고조건에 대한 구조물의 예상최대변위를 구한 후, 두 해법에 의한 결과를 비교분석하였다.

  • PDF

An Investigation of Higher Order Forces on a Vertical Truncated Cylinder

  • 부성윤
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.214-214
    • /
    • 2003
  • During a model test of Hutton TLP, a "ringing" response was first observed about 20 years ago. This phenomenon is a resonant build up over the time of wave period and this burst-like motion can cause the extreme load on the TLP tether. It is often detected in the large and steep irregular waves but the generation mechanism leading to the "ringing" is not yet well understood. According to the research since then, the higher order harmonic components may account for the "ringing" on the floating offshore structures. The main purpose of the present research is, thus, to measure the higher harmonic forces exerted on a vertical truncated circular column and to compare them with available data. A vertical truncated cylinder with a diameter of 3.5inch and a draft of 10.5inch is used as a test structure, which is a scaled model of ISSC TLP column. The cylinder is installed at a distance of 45ft from the wave maker in order to avoid parasitic waves created in the wave flap. Attached to the upper part of the cylinder are two force gages to measure the horizontal (surge) and vertical (heave) forces on the cylinder. The incoming waves are Stokes waves with a slope ranging from 0.06 to 0.24. The forces and waves are measured for 60 seconds with a sampling rate of 50 Hz. Among the recorded data, the first 10 waves are excluded because of transient behavior of the waves and the next The horizontal and vertical forces are analyzed up to 5th order harmonics. The horizontal forces are then compared to the values from the theoretical model called "FNV model". In addition, force transfer functions are also investigated. Major findings in this research are below. 1) The first order forces measured are slightly larger than the theoretical values of "FNV model" 2) The "FNV model" considerably overpredicts the second order forces. 3) The larger the amplitude and more extreme the wave slope, the smaller the predictions are compared to the experimental. 4) The higher harmonic forces are significantly smaller than the first harmonic force for all wave parameters. 5) The normalized forces vs. waves slopes are almost constant in the lower harmonics but vary a lot in the higher harmonics. 6) The trend of forces is more nonlinear in the horizontal forces than in the vertical forces as the wave slope increases. 7) The part of the results above is also observed by other researchers and confirmed again through the present work.

  • PDF

이중 유공슬릿 케이슨에 의한 반사특성 (The Reflection Characteristics of a Perforated Slit Caisson with Two Chambers)

  • 허동수;이우동;이현우;김인철
    • 한국해양공학회지
    • /
    • 제24권1호
    • /
    • pp.60-67
    • /
    • 2010
  • Recently, there has been an increase in the construction of various types of coastal structures for efficient wave dissipation, seawater exchange, and so on. Among these, a perforated slit caisson has been widely used to reduce the reflected wave energy and the wave pressure on the structure. Therefore, many studies on the wave force on a caisson, as well as the wave reflection from it, have been carried out with laboratory experiments and numerical analyses, considering it as a 2-D problem. However, because a structure like a perforated slit caisson has a variable 3-D shape, waves forces should be considered as a 3-D problem. Therefore, in this paper, a fully-nonlinear 3-D numerical model (LES-WASS-3D) is proposed to examine the reflection characteristics of a perforated slit caisson with two chambers. The numerical model, LES-WASS-3D, was verified in a 3-D wave field by a comparison with existing experimental data for wave reflection coefficients. Then, using the numerical results, the reflection from a perforated slit caisson with two chambers was examined in relation to wave steepness, chamber width, and the shape/porosity of perforated slit.

Azimuthal Angle Scan Distribution, Third Order Response, and Optical Limiting Threshold of the Bismarck Brown Y:PMMA Film

  • Fadhil Abass Tuma;Hussain Ali Badran;Harith Abdulrazzaq Hasan;Riyadh Chassib Abul-Hail
    • Current Optics and Photonics
    • /
    • 제7권6호
    • /
    • pp.721-731
    • /
    • 2023
  • This paper studies various roughness parameters, besides waviness, texture, and nonlinear parameters of Bismarck brown Y (BBY)-doped Poly(methyl methacrylate) (PMMA) films based on the computed values of optical limiting (OL) threshold power and nonlinear refractive index. The films' morphology, grain size, and absorption spectra were investigated using atomic force microscopy in conjunction with ultraviolet-visible (UV-Vis) spectrophotometer. The particle size of the films ranged between 4.11-4.51 mm and polymer films showed good homogeneity and medium roughness, ranging from 1.11-4.58 mm. A polymer film's third-order nonlinear optical features were carried out using the Z-scan methodology. The measurements were obtained by a continuous wave produced from a solid-state laser with a 532 nm wavelength. According to the results, BBY has a nonlinear refractive index of 10-6 cm2/W that is significantly negative and nonlinear. The optical limiting thresholds are roughly 10.29, 13.52, and 18.71 mW, respectively. The shift of nonlinear optical features with the film's concentration was found throughout the experiment Additionally, we found that the polymer samples have outstanding capabilities for restricting the amount of optical power that may be transmitted through them. We propose that these films have the potential to be used in a wide variety of optoelectronic applications, including optical photodetectors and optical switching.

Seismic response of single-arch large-span fabricated subway station structure

  • He, Huafei;Li, Zhaoping
    • Earthquakes and Structures
    • /
    • 제23권1호
    • /
    • pp.101-113
    • /
    • 2022
  • A new type of fabricated subway station construction technology can effectively solve these problems. For a new type of metro structure form, it is necessary to clarify its mechanical properties, especially the seismic performance. A soil-structure elastoplastic finite element model is established to perform three-dimensional nonlinear dynamic time-history analysis based on the first fabricated station structure-Yuanjiadian station of Changchun Metro Line 2, China. Firstly, the nonlinear seismic response characteristics of the fabricated and cast-in-place subway stations under different seismic wave excitations are compared and analyzed. Then, a comprehensive analysis of several important parameters that may affect the seismic response of fabricated subway stations is given. The results show that the maximum plastic strain, the interlayer deformation, and the internal force of fabricated station structures are smaller than that of cast-in-place structure, which indicates that the fabricated station structure has good deformation coordination capability and mechanical properties. The seismic responses of fabricated stations were mainly affected by the soil-structure stiffness ratio, the soil inertia effect, and earthquake load conditions rarely mentioned in cast-in-place stations. The critical parameters have little effect on the interlayer deformation but significantly affect the joints' opening distance and contact stress, which can be used as the evaluation index of the seismic performance of fabricated station structures. The presented results can better understand the seismic responses and guide the seismic design of the fabricated station.

전동기 친화형 출력필터를 이용한 영구자석 동기전동기의 센서리스 구동 성능 향상 (Performance Improvement of Sensorless PMSM Drives using Motor Friendly Output Filter)

  • 부한영;백승훈;한상훈;조영훈
    • 전력전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.329-332
    • /
    • 2020
  • A back-electromotive force (back-EMF) estimator for a permanent magnet synchronous motor (PMSM) uses the three-phase voltage references of a current controller to estimate rotor position. However, owing to voltage drops caused by the nonlinear characteristics of switches and passive components, the actual voltage in the motor and the three-phase voltage reference may not match. This study proposes a sensorless control method using a sine-wave output filter applied between the motor drive system and PMSM. The precise voltage in the motor can be measured with the sine-wave output filter and applied to the input of the estimator. Moreover, given that the voltage in the motor can be measured precisely at extremely low speeds, the stable operation range of the back-EMF estimator can be secured. Experimental results show that the proposed sensorless control method has stable operation at extremely low speeds compared with conventional sensorless control.

Comparison of simulated platform dynamics in steady/dynamic winds and irregular waves for OC4 semi-submersible 5MW wind-turbine against DeepCwind model-test results

  • Kim, H.C.;Kim, M.H.
    • Ocean Systems Engineering
    • /
    • 제6권1호
    • /
    • pp.1-21
    • /
    • 2016
  • The global performance of the 5 MW OC4 semisubmersible floating wind turbine in random waves with or without steady/dynamic winds is numerically simulated by using the turbine-floater-mooring fully coupled dynamic analysis program FAST-CHARM3D in time domain. The numerical simulations are based on the complete second-order diffraction/radiation potential formulations along with nonlinear viscous-drag force estimations at the body's instantaneous position. The sensitivity of hull motions and mooring dynamics with varying wave-kinematics extrapolation methods above MWL(mean-water level) and column drag coefficients is investigated. The effects of steady and dynamic winds are also illustrated. When dynamic wind is added to the irregular waves, it additionally introduces low-frequency wind loading and aerodynamic damping. The numerically simulated results for the 5 MW OC4 semisubmersible floating wind turbine by FAST-CHARM3D are also extensively compared with the DeepCWind model-test results by Technip/NREL/UMaine. Those numerical-simulation results have good correlation with experimental results for all the cases considered.

Effects of soil-structure interaction and variability of soil properties on seismic performance of reinforced concrete structures

  • Mekki, Mohammed;Hemsas, Miloud;Zoutat, Meriem;Elachachi, Sidi M.
    • Earthquakes and Structures
    • /
    • 제22권3호
    • /
    • pp.219-230
    • /
    • 2022
  • Knowing that the variability of soil properties is an important source of uncertainty in geotechnical analyses, we will study in this paper the effect of this variability on the seismic response of a structure within the framework of Soil Structure Interaction (SSI). We use the proposed and developed model (N2-ISS, Mekki et al., 2014). This approach is based on an extension of the N2 method by determining the capacity curve of the fixed base system oscillating mainly in the first mode, then modified to obtain the capacity curve of the system on a flexible basis using the concept of the equivalent nonlinear oscillator. The properties of the soil that we are interested in this paper will be the shear wave velocity and the soil damping. These parameters will be modeled at first, as independent random fields, then, the two parameters will be correlated. The results obtained showed the importance of the use of random field in the study of SSI systems. The variability of soil damping and shear wave velocity introduces significant uncertainty not only in the evaluation of the damping of the soil-structure system but also in the estimation of the displacement of the structure and the base-shear force.

프리스트레스트 보의 콘크리트 응력 수준 평가를 위한 비선형 초음파 공진 기법의 적용 (Adoption of Nonlinear Resonant Ultrasonic Spectroscopy for the Evaluation of Stress State on Concrete in Prestressed Beam)

  • 김규진;곽효경
    • 한국전산구조공학회논문집
    • /
    • 제30권3호
    • /
    • pp.215-222
    • /
    • 2017
  • 프리스트레스트 보의 인장력 변화에 따른 콘크리트 응력 수준을 평가하기 위하여, 초음파를 이용하는 기존의 방법보다 개선된 비선형 초음파 공진 기법의 도입을 제안하였다. 이는 동일하게 초음파를 사용하는 선형의 기법보다 월등히 높은 민감도를 보이므로 초기 상태의 응력 평가에도 유리하다. 비선형 초음파 공진 기법은 초음파 통과시 매질 상태에 따른 공진 주파수의 변화의 정도로부터 계산되는 비선형 인자의 값을 측정하며, 측정 결과는 콘크리트의 응력 상태와도 밀접한 연관을 갖는다. 본 연구에서는 유압 펌프를 통한 인장력 작용에 따른 비선형 인자의 측정을 수행함으로써 두 인자 사이에 밀접한 연관성이 있음을 확인하고, 반복적인 하중 이력의 작용이 비선형 인자의 변화에 미치는 영향을 분석하였다. 추가적으로, 선형 초음파 전파 속도 측정 결과를 비교하여 제안한 방법의 민감도를 검증하였다. 측정 결과를 통해 프리스트레스트 보의 콘크리트 응력 수준 평가를 위한 비선형 초음파 공진 기법의 적용 가능성을 확인하였다.