• 제목/요약/키워드: Noninvasive measurement

검색결과 108건 처리시간 0.025초

설문과 비침습적 검사를 통하여 심혈관계 건강 정도를 알려주는 심혈관지수의 개발 (Development of a Cardiovascular Index That Estimates Cardiovascular Health Degree by Survey and Noninvasive Examination)

  • 이종선;정인욱
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.459-466
    • /
    • 2014
  • An index was developed that estimates cardiovascular health degree with easily available physiological information such as survey and noninvasive measurement. The survey score was calculated by utilizing questions related to personal disease history, self-feeling, and management state. The measurement score was calculated using physiological parameters such as blood pressure, accelerated plethysmograph(APG), and heart rate variability(HRV), and augmentation index(AI). In order to evaluate effectiveness of the cardiovascular index and modify weighting factors used in each item, a clinical trial was done in a general hospital. The cardiovascular index showed a clear correlation of 0.685 with the doctor's score on the cardiovascular health degree. The correlation between the self-estimated score and doctor's score was as low as 0.217. The large gap between these two scores demonstrated necessity of more objective tools like the cardiovascular index. The cardiovascular score showed a significant difference between normal persons and patients suffering hypertension or diabetes. (p=0.000).

카드뮴 중독 흰쥐에 대한 Noninvasive Biomarker로서의 요중 Ascorbic Acid에 관한 연구 (A Study of Urinary Ascorbic Acid as a Noninvasive Biomarker for Cadmium-Intoxication in Rats)

  • 안승주;김용호;류재두;이용우
    • 대한의생명과학회지
    • /
    • 제3권2호
    • /
    • pp.151-160
    • /
    • 1997
  • 본 연구는 카드뮴의 이용 및 환경 오염의 증가로 일어날 수 있는 카드뮴 중독에 대한 새로운 생물학적 지표로서의 요중 ascorbic acid를 평가하기 위하여 실험적으로 중독시킨 Sprague-Dawley종의 흰쥐를 이용하여 요중 ascorbic acid측정, 신장의 조직병리학적 조사 및 생화학적 간 기능 검사를 실시하였다. 측정 된 요중 ascorbic acid 농도의 전 실험기간 (50일) 평균치는 실험군I (카드뮴 100 ppm)이 214.0 mg/dl, 실험군II (카드뮴 200 ppm)가 254.3 mg/dl로 대조군 9.0 mg/dl에 비해 각각 24배 및 28배의 증가를 보였다. 조직병리학적 소견으로는 신장의 근위 세뇨관에서 단백뇨의 원인으로 추정되는 호산성 초자양 물질이 관찰되어 신장의 손상이 있었고, 생화학적 분석에서 실험군I에서 AST, ALT의 수치가 대조군의 143 mg/dl, 50 mg/dl에 비해 각각 199 mg/dl, 88 mg/dl, 실험군II가 270 mg/dl, 226 mg/dl로 나타나 간 기능의 손상이 있었음을 알 수 있었다. 이상의 결과로 실험동물이 카드뮴에 노출됨에 따라 그 아만성 독성으로서 간장 및 신장 기능의 손상이 있었고 또한 요중의 ascorbic acid가 현저하게 증가되어 요중 ascorbic acid가 실험 동물의 카드뮴 노출에 대한 noninvasive 진단 지표로서 활용될 수 있을 것으로 기대된다.

  • PDF

FPGA를 이용한 LUTS 진단 시스템 구현 및 평가 (Implementation and Evaluation of the LUTS Diagnosis System Using FPGA)

  • 정도운;정완영;전계록
    • 융합신호처리학회논문지
    • /
    • 제8권1호
    • /
    • pp.6-14
    • /
    • 2007
  • 요역동학검사는 하부요로계의 이상증상을 진단하기위하여 수행된다. 일반적으로 임상에서 행해지는 요역동학검사에서는 침습적인 방법으로 방광을 채운 후 배뇨하는 절차를 거친다. 하지만 이러한 방법은 카테터를 삽입해야하므로 환자에게 고통을 수반하게 한다. 본 연구에서는 비침습적이고 보다 편리한 방법으로 하부요로계의 기능을 평가할 수 있는 시스템을 구현하고자 하였다. 비침습적인 방법으로 하부요로증상(lower urinary tract symptoms, LUTS)의 진단을 위하여 배뇨시 요속, 요류음, 비침습적 방광내압을 측정할 수 있는 시스템을 구현하였다. 구현된 시스템은 센서부, 신호처리부, FPGA를 이용한 시스템 제어부 그리고 PC모니터링 프로그램으로 구성하였다. 그리고 구현된 계측시스템의 평가를 위하여 FPGA 시스템 제이부의 시뮬레이션을 수행하였고 인체의 하부요로계를 모식화한 실험장치를 구현하였다. 실험장치를 이용한 측정부의 평가결과 요속측정부의 평균에러율이 1.08%, 계수변화율이 1.48로 평가되었다. 그리고 비침습적 방광내압부는 평균에러율이 2.41%, 계수변화율이 2.81로 나타났다. 요류음신호의 시간영역과 주파수영역에서의 분석위해 평균실효치전력(average RMS power)과 주파수영역에서의 중심주파수(median frequency, MF)를 분석하였으며, 그 결과 $60{\sim}160Hz$의 중심주파수대에서 폐색을 가장 잘 반영하였다.

  • PDF

기능성 위장관 질환에서 핵의학 검사의 역할 (Scintigraphic Evaluation of Gastrointestinal Motility Disorders)

  • 최재걸
    • 대한핵의학회지
    • /
    • 제35권1호
    • /
    • pp.1-11
    • /
    • 2001
  • Current scintigraphic tests of gastrointestinal motor function provides relevant pathophysiologic information, but their clinical utility is controversial. Many scintigraphic methods are developed to investigate gastrointestinal motility from oral cavity to colon. These are esophageal transit scintigraphy, oropharyngeal transit study, gastric emptying test, small bowel transit time measurement, colon transit study and gastroesopahgeal reflux scintigraphy. Scintigraphy of gastrointestinal tract is the most physiologic and noninvasive method to evaluate gastrointestinal motility disorders. Stomach emptying test is regarded as a gold standard in motility study. Gastrointestinal transit scintigraphy also has a certain role in assessment of drug effect to GI motility and changes alter therapy of motility disorders. Scintigraphy provides noninvasive and quantitative assessment of physiological transit throughout the gastrointestinal tract, and it is extremely useful for diagnosing gastrointestinal motor dysfunction. This article reviews the current procedures, indications, significance and guidelines for gastrointestinal motility measurements by scintigraphy.

  • PDF

ECG-NIBP-$SpO_2$ 환자감시장치 개발 (Development of ECS-NIBP-$SpO_2$ Patient Monitoring System)

  • 김남현;심원흠;이건기;라상원;김경하
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

배뇨력 측정을 통한 하부요로계의 보상성기능항진 평가 (Estimation of compensatory hypertrophy in lower urinary system using void force measurement)

  • 정도운;전계록
    • 센서학회지
    • /
    • 제15권6호
    • /
    • pp.449-456
    • /
    • 2006
  • The purpose of urodynamic investigation is to obtain the information on the function of the urinary system. The aim of this study is to acquire the useful information of lower urinary tract symptom (LUTS) diagnosis through void force signal as noninvasive method. The system which could evaluate the function of compensatory hypertrophy with noninvasive and comfortable method was implemented to measure uroflow and void force during urination. The implemented system composes of the sensor parts, signal conditioning parts and PC monitoring program. For the evaluation of the implemented system, the simulation of control part of the system was performed and the model system for the lower urinary system was designed. The superiority of a measuring characteristic of the implemented system was verified using the model system. From the evaluation of the model system, we have found out that the void force was dependent on the occlusion degree and compensatory hypertrophy significantly.

상악 견치의 저항 중심에 관한 Laser speckle interferometry와 holographic interferometry볼 이용한 실험적 연구 (EXPERIMENTAL STUDY OF THE CENTER OF RESISTANCE OF A MAXILLARY CANINE USING LASER SPECKLE INTERFEROMETRY AND HOLOGRAPHIC INTERFEROMETRY)

  • 이수룡
    • 대한치과교정학회지
    • /
    • 제18권2호
    • /
    • pp.289-308
    • /
    • 1988
  • The center of resistance is a important determining factor of tooth movement pattern. Laser speckle interferometry, recently developed for noninvasive measurement of small displacements (microns), was used to detect the center of resistance of a maxillary canine which has normal tooth axis and distal curved root in dry human skull. Laser holographic interferometry was used to verify the results of laser speckle interferometry The following result were obtained; 1. In measurement of the degree of rotation, center of resistance was localized when the traction line passed 4.4/18.0 level from alveola crest to root apex. 2. In measurement of the degree of tipping, center of resistance was localized when the traction line passed 4.6/18.0 level from alveola crest to root apex. 3. In holographic determination, the center of resistance was observed when the traction line passed between 3mm to 6mm level from alveola crest to root apex, therefore the results using laser speckle interferometry was coincided with holographic results.

  • PDF

골밀도 측정의 올바른 임상 적용 (Clinical Application of Bone Mineral Density Measurement)

  • 김덕윤
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.275-281
    • /
    • 2004
  • Compared with the earlier technique of dual photon absorptiometry (DPA) using $^{153}Gd$ radionuclide source, dual energy X-ray absorptiometry (DXA) has advantages of higher precision, accuracy and shorter scanning time. Despite the change from DPA to DPX, the nuclear medicine physicians has remained one of major suplier of this service due to long-standing use of DPA. Among many kinds of bone densitometries, DXA is the "gold standard" for the noninvasive diagnosis of osteoporosis. Especially there is no role for peripheral devices in the monitoring of patients on therapy. But, there are some areas of controversy related to the application of DXA, such as proper site of measurement, accurate interpritation, appropriate use of T-score, and the reference population young database. And the accuracy, precision, and quality control issues relating to bone density measurement are important subjects. To address these issues, the International Society for Clinical Densitometry (ISCD) has convened two Position Development Conferences and addressed official positions. This review deals the key elements of ISCD position paper and other important issues on the management of bone densitometry.

A Spatial-domain Fourier Transform Infrared Spectrometer: Application for Analyte Measurement in Cell Culture Media

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • 제9권4호
    • /
    • pp.151-156
    • /
    • 2005
  • A spatial-domain Fourier Transform (FT) infrared (IR) spectrometer coupled with a PtSi Schottky­barrier IR detector plane was developed in the spectral range of $2.0-2.5{\mu}m$ for noninvasive measurement of analyte concentrations in cell culture media during cell culture processing. A key optical component of the spectrometer is a Savart plate which is a birefringent polarizer generating coherent two rays for interfering. The spectral resolution of the spectrometer was determined as $71cm^{-1}$ (${\~}0.05{\mu}m$ at $2.5{\mu}m$). Clear IR fringe patterns were imaged on the IR detector plane. The feasibility of the spectrometer for our application was investigated by measuring absorbance spectra of glucose and fetal bovine serum (FBS) which are important compounds in cell culture media. Experiment results show that the spectral quality of glucose and FBS was comparable with the standard spectra acquired with a commercial FT-IR spectrometer, presenting the feasibility of the spectrometer to perform analyte measurement in cell culture media.