• Title/Summary/Keyword: Nondestructive system

Search Result 598, Processing Time 0.024 seconds

Complete Modeling of an Ultrasonic NDE Measurement System - An Electroacoustic Measurement Model

  • Dang, Changjiu;Lester W. Schmerr, Jr.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.1
    • /
    • pp.1-21
    • /
    • 2001
  • It will be shown how models can simulate all the elements of an ultrasonic NDE measurement system, including the pulser/receiver, cabling, transducer(s), and the acoustic/elastic waves fields. When combined, these models form what is called the electroacoustic measurement model. It will be demonstrated how this electroacoustic measurement model can be used to conduct parametric transducer and system studies and how the model can form the basis for experimentally characterizing all the elements of the ultrasonic measurement system, using purely electrical measurements.

  • PDF

Nondestructive Evaluation of Tempering Process of S45C Steel using DC Potential Drop Measurement (DC Potential Drop 측정을 이용한 S45C강의 템퍼링과정 비파괴 평가)

  • Park, Y.K.;Ahn, B.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.77-82
    • /
    • 1989
  • DC potential drop(DCPD) measurement system was made and the optimum measuring conditions have been studied. The room temperature resistivity of commercially available medium carbon steel(S45C) was measured using this technique. DCPD was measured in the specimens which were hardened and tempered at different temperatures. It was found that DCPD reflected the change of the microstructure during tempering very sensitively. It was possible to monitor the stage of tempering of S45C steel nondestructively using DCPD measurement.

  • PDF

Imaging Technique Based on Continuous Terahertz Waves for Nondestructive Inspection (비파괴검사를 위한 연속형 테라헤르츠 파 기반의 영상화 기술)

  • Oh, Gyung-Hwan;Kim, Hak-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.328-334
    • /
    • 2018
  • The paper reviews an improved continuous-wave (CW) terahertz (THz) imaging system developed for nondestructive inspection, such as CW-THz quasi-time-domain spectroscopy (QTDS) and interferometry. First, a comparison between CW and pulsed THz imaging systems is reported. The CW-THz imaging system is a simple, fast, compact, and relatively low-cost system. However, it only provides intensity data, without depth and frequency- or time-domain information. The pulsed THz imaging system yields a broader range of information, but it is expensive because of the femtosecond laser. Recently, to overcome the drawbacks of CW-THz imaging systems, many studies have been conducted, including a study on the QTDS system. In this system, an optical delay line is added to the optical arm leading to the detector. Another system studied is a CW-THz interferometric imaging system, which combines the CW-THz imaging system and far-infrared interferometer system. These systems commonly obtain depth information despite the CW-THz system. Reportedly, these systems can be successfully applied to fields where pulsed THz is used. Lastly, the applicability of these systems for nondestructive inspection was confirmed.

Development of MFL Testing System for the Inspection of Storage Tank Floor (저장탱크 바닥면 검사를 위한 누설자속 탐상 시스템 개발)

  • Won, Soon-Ho;Cho, Kyung-Shik;Lee, Jong-O;Chang, Hong-Keun;Joo, Gwang-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.38-44
    • /
    • 2002
  • MFL method is a qualitative inspection tool and is a reliable, fast and economical NDT method. The application of MFL method to the inspection of storage tank floor plates has been shown to be a viable means. Examination of tank floors previously depended primarily upon ultrasonic test methods that required slow and painstaking application. Therefor most ultrasonic inspection of storage tank has been limited to spot testing only. Our NDE group have developed magnetic flux leakage system to overcome limitation of ultrasonic test. The developed system consists of magnetic yoke, array sensor, crawler and software. It is proved that the system is able to detect artificial flaw like 3.2mm diameter, 1.2mm depth in 6mm thick steel plate.

Nondestructive Evaluation of the Flaw in a Ceramic Ferrule by Resonant Ultrasound Spectroscopy (공명초음파분광법을 이용한 페롤의 비파괴결함평가)

  • 김성훈;백경윤;김영남;양인영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.108-117
    • /
    • 2004
  • In this paper, a measuring NDT(nondestructive testing) system using RUS(Resonant Ultrasound Spectroscopy) was built for nondestructive evaluation of the flaw in a ceramic Ferrule. The principle of RUS is that the mechanical resonant frequency of the materials depends on density, and the coefficient of elasticity. The RUS system is the measuring which is to exite specimen and to inspect the difference of natural frequency pattern between acceptable specimen and specimen which has some defects. RUS system is configured of spectrum analyzer, power amplifier, PZT sensor and support frame. For defect evaluation by the RUS, we performed to measure natural frequency of Ferrule, both acceptable and cracked. In the case of Ferrule, the resonant frequency of cracked-Ferrule existed to higher frequency band than acceptable-Ferrule.

Development of an Optimum Void Detection Chart using Heat Transfer Simulation (열전달 시뮬레이션을 통한 최적공극탐지 차트개발)

  • Choi, Hyun-Ho;Park, Jin-Hyung;Ji, Goang-Seup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.241-244
    • /
    • 2006
  • It is essential to develop a large capacity, non-contact nondestructive inspection system having high reliability to investigate repaired and strengthened structures. Nowadays, an infrared camera is widely used in non-contact nondestructive inspection system. Because an infrared camera is sensitive to the surrounding environment, it is necessary to improve a sensitivity of thermal image information and a relationship between defects and thermal image information. In this papaer, presented is an optimum void detection chart for the optimum conditions to detect infrared rays from inside and outside defects like voids and cracks in concrete structures using extensive computer simulation. Sensitivity studies are performed with respect to variables influencing the temperature distribution such as heating temperature, heating time, and geometries of defect, etc. It may be stated that it could be successfully utilized for the non-contact nondestructive inspection system to detect defects in concrete structures.

  • PDF

Equivalency Assessment for an Eddy Current System Used for Steam Generator Tubing Inspection

  • Cho, Chan-Hee;Lee, Tae-Hun;Yoo, Hyun-Ju;Moon, Gyoon-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.258-267
    • /
    • 2015
  • Eddy current testing is widely used for inspecting steam generator tubing in nuclear power plants (NPPs). The inspection technique for steam generator tubing in NPPs should be qualified in accordance with examination guidelines. When the components of a qualified system such as eddy current tester, probe, and data analysis program, are changed, the equivalency of the modified system to the originally qualified system must be verified. The eddy current tester is the most important part of an eddy current testing system because it excites and transmits alternating currents to the probe, receives coil impedance of the probe and generates signals for anomalies. The Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed an eddy current testing system with an eddy current tester and data acquisition-analysis program for inspecting the steam generator tubing in NPPs; this system can be used for an array probe and as a bobbin and rotating probes. The equivalency assessment for the currently developed system was carried out, and we describe the results in this paper.

Nondestructive Evaluation of Creep Damage Materials by using Ultrasonic Spectrum Analysis (초음파 Spectrum 해석에 의한 Creep 손상재의 비파괴평가)

  • Kim, C.I.;Yi, W.;Lim, Y.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.2
    • /
    • pp.42-47
    • /
    • 1991
  • Nondestructive evaluation study was made on creep damage materials by ultrasonic spectrum analysis. The evaluation methods was developed in order to predict the change of ultrasonic attenuation with increasing creep damage. A new algorithm for the improvement of measuring accuracy of ultrasonic attenuation using a spectrum analysis has been developed. Normally, the ultrasonic attenuation is evaluated from 1st and 2nd peak values of the pulse-echo ultrasonic wave. The algorithm developed is incorporated in a measuring system which consists of a personal computer with ultrasonic apparatus and a digital storage oscilloscope. By the spectrum analysis method, it become popssible to describe approximately the attenuation change with increassing creep damage in Cr-Mo-V forging.

  • PDF

PSI/ISI Data Management System by using Personal Computer in Nuclear Power Plant (퍼스널 컴퓨터를 이용한 원자력발전소의 가동전.중 검사자료 관리 체제 전산화)

  • Song, S.J.;Sim, C.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 1989
  • In nuclear power plants, nondestructive examinations(NDE) plays an important role in ensuring the integrity and reliability operation. As the number of plants and operational time increased, manual handling of voluminous data associated with PSI/ISI(preservice/inservice inspection) could result in many errors or mistakes in writing the examination plan or other reports. Several new approaches to process the data have been attempted and DBMS(Data Base Management System) has been well known concept with a faster and more accurate data processing. This paper proposes an application program, called NDTSYS designed with DBMS in micro computer. The program could be used for a tool to add new records to a data base, change existing records, delete records and request reports with the data base. It would be helpful to the user who manage the PSI/ISI data with minimal time and effort.

  • PDF