• Title/Summary/Keyword: Non-point source water pollution

Search Result 327, Processing Time 0.021 seconds

Removal of Suspended Solids from Stormwater Runoff Using a Fabric Filter System (섬유필터를 사용한 강우유출수의 부유물질 제거 방법의 개발)

  • Koo, Young Min;Kim, Jaeyoung;Kim, Byung Ro;Seo, Dongil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.165-174
    • /
    • 2015
  • Non-point source pollution associated with suspended solids in stormwater has been known to often adversely affect surface water ecosystems. Various methods of treating stormwater in the basin area before the stormwater reaches the receiving body of water have been developed. However, these treatment methods tend to be costly to install and also to maintain. In this study, an economical way of removing TSS (total suspended solids) from stormwater runoff with a fabric filter system was developed. Polyester was chosen as a fabric-filter material, because it was found to be economical in cost and relatively resistant to various chemicals. An experimental device was developed and used to determine filtration rates through polyester fabric samples of a series of several pore-opening sizes ($20{\mu}m$ to $94{\mu}m$) under a series of water-heads (0.25 to 1 m). It was found that the filtration rate increased as the size of water head increased. It was also found that the smaller the pore size of the fiber filter was, the higher the TSS removal efficiency was. However, the TSS removal efficiency was not found to be much different among the filters with different sizes of pore opening due to the fact that most mass of TSS was associated with large particles.

The Simulation of Runoff Reduction by the Storage Type of Zermeable Concrete Block Paving on Andong Maskdance Festival Square (저류형 투수블록 설치를 통한 안동국제탈춤광장 유출량 저감효과 모의)

  • Park, Sung Ki;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.293-300
    • /
    • 2018
  • Ihe purpose of this study is to evaluate the effects the storage type of permeable concrete block paving (ST-PCBP) have on runoff reduction and infiltration increasement at Andong Maskdance Festival Square. This was accomplished using the NRCS-curve number method over the last 10 years. Two different scenarios were developed in this study for low impact development (LID) design. For the $1^{st}$ scenario, the walking path and parking lot were install using the ST-PCBP and runoff from the inline skating rink ($3,808m^2$) and lawn ($11,191m^2$) were routed to the ST-PCBP, but the rooftop runoff flowed into the storm water drainage system. For the $2^{nd}$ scenario, one of the non-structural BMPs, disconnected impervious surface (DIS), was applied so additional runoff from rooftop would enter the ST-PCBP. It was determined that ST-PCBP could significantly reduce surface runoff from the study area and increase infiltration with 71% and 88% of surface runoff reduction and 151% and 215% of infiltration increasement for scenarios 1 and 2, respectively. The effect of LID in the $2^{nd}$ scenario was better than the $1^{st}$ scenario, therefore DIS in conjunction with ST-PCBP could be a more cost-effective LID application.

Estimation of Agricultural Water Quality Using Classification Maps of Water Chemical components in Seonakdong River Watershed (수질성분 분포도를 이용한 서낙동강 수계 농업용수 수질평가)

  • Ko, Jee-Yeon;Lee, Jae-Sang;Kim, Choon-Song;Jeong, Ki-Yeol;Choi, Young-Dae;Yun, Eul-Soo;Park, Seong-Tae;Kang, Hwang-Won;Kim, Bok-Jin
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.138-146
    • /
    • 2006
  • To understand the status of water quality and work out a suitable countermeasures in Seonakdong watershed which has poor agro- environmental condition because of severe point and non-point source pollution by popularized city and near sea, we investigated the pollution sources and water quality from '03 and '05 and the result were mapped with GIS and RS for end-users's convenient comprehense and conjunction of water quality and geological data. The most degraded tributary was Hogeo stream which was affected directly by highly popularized Gimhae city, the main pollution source of the watershed. The pollution of tributaries in watershed increased the T-N of main body that reached over 4 mg/L during dry season. Pyeonggang stream and the lower part of main water way were suffered from high salt contents induced near sea and the EC value of those area were increased to 2.25 dS/m. The delivered loads of T-N and T-P were largest in Joman river as 56% and 61% of total delivered loads 1mm tributaries because of lots of stream flow. When Management mandate for irrigation water in Seonakdong river watershed was mapped for estimating integrated water quality as the basis of classification of EC and T-N contents in water, Hogeo and Shineo catchments were showed the requiring countermeasures none against nutrients hazard and Pyeonggang catchment was the vulnerable zone against nutrients and salts hazard. As the result, Seonakdong watershed had very various status of water quality by characteristics of catchments and countermeasures for improving water quality and crop productivity safely should changed depend on that.

Characteristics and Assessment of Metal Pollution and their Potential Source in Stormwater Runoff from Shihwa Industrial Complex, Korea (시화산업단지 강우유출수 내 중금속 오염도 평가 및 오염원 추적 연구)

  • Lee, Jihyun;Jeong, Hyeryeong;Choi, Jin-Young;Ra, Kongtae
    • Korean Journal of Ecology and Environment
    • /
    • v.53 no.1
    • /
    • pp.91-101
    • /
    • 2020
  • Stormwater runoff is known as a major non-point water pollution source that transports heavy metals, which have accumulated in road surface, to stream and coastal area. Dissolved and particulate metals in stormwater runoffs have been investigated to understand the outflow characteristics of heavy metals during rainfall events and to identify their pollution sources. The concentration of dissolved Co and Ni decreased after the outflow with high concentrations at the beginning of the rainfall, and other metals showed different characteristics depending on the rainfall and rate of discharge. Particulate metals showed a similar trend with the temporal variation of suspended solids concentration in stormwater runoffs. The results of geo-accumulation index (Igeo) indicated that the stormwater runoffs from industrial region were very highly polluted with Cu, Zn and Cd. As a result of comparing the metal concentrations of <125 ㎛ for road dust near the study area, Cu, Zn and Cd were originated from inside of metal manufacturing facilities rather than traffic activities at road surface and these metals accumulated on the surface area of facilities were transported to the water environments during stormwater event. The average discharged amounts of heavy metals for one rainfall event were Cr 128 g, Co 12.35 g, Ni 98.5 g, Cu 607.5 g, Zn 8,429.5 g, As 6.95 g, Cd 3.7 g, Pb 251.75 g, indicating that metal runoff loads in the stormwater runoffs are closely related to surrounding industry types.

Evaluation of Aquatic Ecological Characteristics in Sinpyongcheon Constructed Wetlands for Treating Non-point Source Pollution (비점오염원 저감을 위한 신평천 인공습지의 수생태학적 특성 평가)

  • Seo, Dong-Cheol;Kang, Se-Won;Lim, Byung-Jin;Park, Jong-Hwan;Kim, Kap-Soon;Lee, Jun-Bae;Kim, Hyun-Ook;Heo, Jong-Soo;Chang, Nam-Ik;Seong, Hwan-Hoo;Cho, Ju-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.400-407
    • /
    • 2011
  • To evaluate the aquatic ecological characteristics in Sinpyongcheon constructed wetlands for treating nonpoint source pollution, the removal rates of nutrients in water, the total amounts of T-N and T-P uptakes by water plants, and chemical characteristics of T-N and T-P in sediment were investigated. The concentrations of BOD, COD, SS, T-N and T-P in inflow were 0.07~1.47, 0.60~2.65, 0.50~4.60, 1.38~6.26 and $0.08{\sim}0.32mg\;L^{-1}$, respectively. The removal rates of BOD, COD, SS, T-N, and T-P were 14%, 6%, 18%, 24%, and 10%, respectively. The maximum amount of T-N uptake by water plants in August was $813mg\;plant^{-1}$ for Phragmites communis TRIV in $2^{nd}$ bed, $1,172mg\;plant^{-1}$ for Typha orientalis PRESL in $3^{rd}$ bed, respectively. The maximum amount of T-P uptake by water plants in August was $247mg\;plant^{-1}$ for Phragmites communis TRIV in $2^{nd}$ bed, $359mg\;plant^{-1}$ for Typha orientalis PRESL in $3^{rd}$ bed, respectively. Organic matter, T-N, and T-P contents in sediments were high in the order of $1^{st}$ bed > $2^{nd}$ bed > $3^{rd}$ bed. Microbial biomass C/N/P ratios in sediments in $1^{st}$, $2^{nd}$, and $3^{rd}$ were 78~110/3~6/1, 73~204/1~6/1, and 106~169/1~6/1, respectively.

Evaluation of Surrogate Monitoring Parameters for SS and T-P Using Multiple Linear Regression and Random Forest (다중 선형 회귀 분석과 랜덤 포레스트를 이용한 SS, T-P 대리모니터링 기법 평가)

  • Jeung, Minhyuk;Beom, Jina;Choi, Dongho;Kim, Young-joo;Her, Younggu;Yoon, Kwangsik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.2
    • /
    • pp.51-60
    • /
    • 2021
  • Effective nonpoint source (NPS) pollution management requires frequent water quality monitoring, which is, however, often costly to be implemented in practice. Statistical techniques and machine learning methods allow us to identify and focus on fundamental environmental variables that have close relationships with NPS pollutants of interest. This study developed surrogate models to predict the concentrations of suspended sediment (SS) and total phosphorus (T-P) from turbidity and runoff discharge rates using multiple linear regression (MLR) and random forest (RF) methods. The RF models provided acceptable performance in predicting SS and T-P, especially when runoff discharge rates were high. The RF models outperformed the MLR models in all the cases. Such finding highlights the potential of RF techniques and models as a tool to identify fundamental environmental variables that are measured in relatively inexpensive ways or freely available but still able to provide information required to quantify the concentrations of NP S pollutants. The analysis of relative importance rates showed that the temporal variations of SS and T-P concentrations could be more effectively explained by that of turbidity than runoff discharge rate. This study demonstrated that the advanced statistical techniques such as machine learning could help to improve the efficiency of NPS pollutants monitoring.

A Study on the Participatory Irrigation Management under Public Irrigation Management System (공적(公的)관리에서의 참여형 관개관리(PIM) 모델)

  • Lee, Sung-Hee;Kim, Tai-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.3
    • /
    • pp.13-17
    • /
    • 2011
  • There was a transition from participatory irrigation management (PIM) to public irrigation management (PubIM) in Korea when Korea Rural corporation and Community (KRC) merged with Farm Land Improvement Associations (FLIAs), which had managed 60 % of irrigation areas. While making a number of achievements, some problems occurred in the public irrigation management, such as lack of farmers' participation, increased amount of water usage, and elevating operating costs. Accordingly, this paper suggested ways to increase efficiency in water usage and reduce operating costs under the public management through the motive power of farmers participation. First, WUGs replaced the discarded water management committee should be reorganized to revive the concept of PIM in the form of autonomously reinforced one and the roles and functions of WUGs and the board of representatives should be strengthened. The member of new type of WUGs should participate in the national and regional water management committees as a stakeholder of irrigation water user. And also new type of WUGs initiates not only the management of irrigation water but also the management of irrigation water quality and non-point source pollution in the watersheds. Those additional activities of WUGs should be properly compensated. Second, subsidies (direct payments) should be provided to faithful farmers as an incentive for their labor supply. Third, water fees could be charged to large scale agriculture companies. Fourth, professional managers could be hired, management targets would be adjusted, and incentives should be offered. These efforts are expected to improve the irrigation management by encouraging farmers' participation under public system.

Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District (하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구)

  • Shin, Hyun Suk;Kim, Mi Eun;Kim, Jae Moon;Jang, Jong Kyung
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1193-1207
    • /
    • 2013
  • Increase of impervious area caused by overdevelopment has led to increase of runoff and then the problem of flooding and NPS were brought up. In addition, as decrease of base flow made groundwater level to decline, a stream that dries up is issued. low impact development (LID) method which is possible to mimic hydrological water cycle, minimize the effect of development, and improve water cycle structure is proposed as an alternative. As introduction of LID in domestic increases, the study on small watershed is in process mainly. Also, analysis of property of hydrological runoff and load on midsize watershed, like sewage treatment district, is required, the study on it is still insufficient. So, area applying LID practices from watershed of Dongrae stream is pinpointed and made the ratio and then expand it to watershed of Oncheon stream. Among low impact development practices, Green Roof, Porous Pavement, and Bio- retention are selected for the application considering domestic situations and simulated with SWMM-LID model of each watershed and improvement of water cycle and reduction of non-point pollution loads was analysed. Improvement of water cycle and reduction of non-point pollution loads were analyzed including the property of rainfall and soil over long term simulation. The model was executed according to scenario based on combination of LID as changing conductivity in accordance with soil type of the watershed. Also, this study evaluated area of LID application that meets the efficiency of conventional management as a criteria for area of LID practices applying to sewer treatment district by comparing the efficiency of LID application with that of conventional method.

Evaluation of treatment efficiencies of pollutants in daecheong lake juwon stream constructed wetlands (대청호 주원천 인공습지의 오염물질 정화효율 평가)

  • Kim, Tae-Hun;Sung, Ki-Eun;Ha, Duk-Ho;Kim, Dong-Hee;Heo, Soon-Uk;Choi, Chung-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.211-222
    • /
    • 2015
  • This study focused on evaluating the efficiency of the removal of non-point source pollution by Daecheong Lake Juwon Stream constructed wetlands. The constructed wetland system is a surface flow type designed in the year 2007 for purifying eutrophic water of Daecheong Lake Juwon Stream. The value of conductivity, suspended solids(SS), chemical oxygen demand using a potassium permanganate($COD_{Mn}$), five-day biochemical oxygen demand($BOD_5$), total nitrogen(T-N), total phosphorous(T-P), and pH in inflow averaged 220.2, 2.46, 3.33, 1.34, 2.00, 0.04 mg/L and 7.24, respectively and in outflow averaged 227.9, 1.12, 3.34, 0.87, 1.16, 0.02 mg/L and 7.45, respectively. The average removal efficiency of constructed wetlands was 30 % for SS, 22 % for $BOD_5$, 45 % for T-N and 31 % for T-P. The removal rates of SS, $BOD_5$ and T-N in the spring, summer and autumn were higher than those in winter. The removal rate of T-P was not significant different in all seasons. The amounts of pollutants removal in the constructed wetlands were higher in the order of $3^{rd}$ < $2^{nd}$ < $1^{st}$ wetland for SS and T-P, $2^{nd}$ < $3^{rd}$ < $1^{st}$ wetland for $BOD_5$ and T-N. Therefore, our findings suggest that the constructed wetlands could well treat the eutrophic Daecheong Lake Juwon Stream waters.

Analysis of the Effect of Water Budget Elements on Flow Duration Characteristics using SWAT-Nak Dong (낙동강유역 SWAT 모형 구축 및 물수지 시나리오에 따른 유황분석)

  • Shin, Hyun-Suk;Kang, Du-Kee;Kim, Sang-Dan
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.3
    • /
    • pp.251-263
    • /
    • 2007
  • In this paper, we constructed the integrated watershed model system, SWAT-Nak Dong that include areal mean precipitaiton, runoff and water balance components in the Nak Dong river basins and with this model system we are capable of estimating streamflows for ungaged river stations and analyzing the variations of the streamflows. SWAT(Soil and Water Assessment Tool) is a conceptual, continous time model that was developed in the early 1990s to assist water resource managers in assessing the impact of management and climate on water supplies and non-point source pollution III watersheds and large river basins. Using the SWAT-Nak Dong system and various scenarios, we analyzed and evaluated the dams and water uses effects on the streamflows.