• 제목/요약/키워드: Non-determination

검색결과 1,031건 처리시간 0.027초

The Comparative Evaluation of Fermented and Non-fermented Soybean Extract on Antioxidation and Whitening

  • Chae, Ga-Yeon;Ha, Bae-Jin
    • Toxicological Research
    • /
    • 제27권4호
    • /
    • pp.205-209
    • /
    • 2011
  • The present study was performed to compare the antioxidative and whitening activities of fermented soybean extract (FSB) and non-fermented soybean extract (SB). Antioxidative and whitening activities of FSB and SB were evaluated by the determination of DPPH, superoxide radical and hydroxyl radical scavenging activities, linoleic acid inhibition activity, and tyrosinase inhibition activity. FSB showed the higher effect than SB in the antioxidative activities. Also FSB showed the better effect than SB in whitening activity. These results demonstrated that the fermentation played a more excellent role than the non-fermentation in antioxidation and whitening. Therefore, this study suggested that FSB could be a useful cosmetic ingredient for antioxidation and skin whitening.

치의학 연구에서의 표본크기 산출 (Sample size determination in dental research)

  • 임회정
    • 대한치과의사협회지
    • /
    • 제52권9호
    • /
    • pp.558-569
    • /
    • 2014
  • Sample size determination is critical, but not easy to do. Sample size defined as the number of observations in a sample to be studied should be big enough to have a high likelihood of detecting a true difference between groups. Practical procedure for determining sample size, using $G^*$power and previous dental articles, was shown in this study. Examples involving independent t-test, paired t-test, one-way analysis of variance(ANOVA), and one-way repeated-measures(RM) ANOVA were used. The purpose of this study is to enable researchers with non-statistical backgrounds to use in practice freely available statistical software G*power to determine sample size and power.

An Integrated Neural Network Model for Domain Action Determination in Goal-Oriented Dialogues

  • Lee, Hyunjung;Kim, Harksoo;Seo, Jungyun
    • Journal of Information Processing Systems
    • /
    • 제9권2호
    • /
    • pp.259-270
    • /
    • 2013
  • A speaker's intentions can be represented by domain actions (domain-independent speech act and domain-dependent concept sequence pairs). Therefore, it is essential that domain actions be determined when implementing dialogue systems because a dialogue system should determine users' intentions from their utterances and should create counterpart intentions to the users' intentions. In this paper, a neural network model is proposed for classifying a user's domain actions and planning a system's domain actions. An integrated neural network model is proposed for simultaneously determining user and system domain actions using the same framework. The proposed model performed better than previous non-integrated models in an experiment using a goal-oriented dialogue corpus. This result shows that the proposed integration method contributes to improving domain action determination performance.

Determination of four Nutrients in Tomato with Near Infrared Spectrometry

  • Liu, Ling;Jin, Tongming
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1514-1514
    • /
    • 2001
  • In this paper a fast non-destructive analytical method to measure various nutrients in the intact tomato---Near infrared Spectrometry NIRs was introduced Using this method the content of some organic acid, vitamin C, reductive sugar, and solid soluble were determined simultaneously. Screen out four wavelengths at 916nm, 1000nm, 1004nm and 832nm to present optimum four optical terms of d$^2$ log(1/R) with second derivative spectra treating data scanned under these wavelengths. The multiple correlation coefficients between these values and those obtained on chemical analysis were 0.983, 0.990, 0.987, and 0.994, respectively, and the standard errors of prediction (SEP) were 0.007, 0.440, 0.037, and 0.057, respectively. These results indicate that NIRs is comparable to chemical methods in both accuracy and precision and is reliable method for determination of nutrients in intact tomato.

  • PDF

Determination of the Principal Directions of Composite Helicopter Rotor Blades with Arbitrary Cross Sections

  • Oh, Taek-Yul;Choi, Myung-Jin;Yu, Yong-Seok;Chae, Kyung-Duck
    • Journal of Mechanical Science and Technology
    • /
    • 제14권3호
    • /
    • pp.291-297
    • /
    • 2000
  • Modern helicopter rotor blades with non-homogeneous cross sections, composed of anisotropic material, require highly sophisticated structural analysis because of various cross sectional geometry and material properties. They may be subjected by the combined axial, bending, and torsional loading, and the dynamic and static behaviors of rotor blades are seriously influenced by the structural coupling under rotating condition. To simplify the analysis procedure using one dimensional beam model, it is necessary to determine the principal coordinate of the rotor blade. In this study, a method for the determination of the principal coordinate including elastic and shear centers is presented, based upon continuum mechanics. The scheme is verified by comparing the results with confirmed experimental results.

  • PDF

Multivariate adaptive regression spline applied to friction capacity of driven piles in clay

  • Samui, Pijush
    • Geomechanics and Engineering
    • /
    • 제3권4호
    • /
    • pp.285-290
    • /
    • 2011
  • This article employs Multivariate Adaptive Regression Spline (MARS) for determination of friction capacity of driven piles in clay. MARS is non-parametric adaptive regression procedure. Pile length, pile diameter, effective vertical stress, and undrained shear strength are considered as input of MARS and the output of MARS is friction capacity. The developed MARS gives an equation for determination of $f_s$ of driven piles in clay. The results of the developed MARS have been compared with the Artificial Neural Network. This study shows that the developed MARS is a robust model for prediction of $f_s$ of driven piles in clay.

4 유기염기착화합물의 분석화학적연구 I. Chlorpromazine Bromthymol Blue Complex 의 분석화학적연구 (Studies on the Organic Base Complexes and their Application to Analytical Chemistry. I. A Study on the Formation of Chlorpromazine Bromothymol Blue Complex and its Application to Analytical Chemistry.)

  • 김차덕;심상혁;서정현
    • 약학회지
    • /
    • 제9권1_2호
    • /
    • pp.14-17
    • /
    • 1965
  • It has been known that the organic base complexes formed with the anionic acid base indicators are highly soluble in non-polar solvents but relatively insoluble in water. In the work reported here the formation of the complex between chloropromazine and bromothymol blue was studied and applied it to the determination of the base. The values to determine the binding ratio of the base with the indicator at pH 3.5 obtained from the application of Job's method of continuous variation and mol ratio method were both 1:1. From the application of this reaction to the determination of the base with carbon tetrachloride as the solvent for the extraction, fairy good results have been obtained.

  • PDF

Method Development of Verapamil in Presence of NSAIDs using RP-HPLC Technique

  • Sultana, Najma;Arayne, M. Saeed;Waheed, Abdul
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권7호
    • /
    • pp.2274-2278
    • /
    • 2011
  • Verapamil is a calcium channel blocker and is classified as a class IV anti-arrhythmic agent. It is used in the control of supra ventricular tachyarrhythmias, and in the management of classical and variant angina pectoris. It is also used in the treatment of hypertension and used as an important therapeutic agent for angina pectoris, ischemic heart disease, hypertension and hypertrophic cardiomyopathy. Verapamil commonly co-administered with NSAIDs (non-steroidal anti-inflammatory drugs) i.e. diclofenac sodium, flurbiprofen, Ibuprofen, mefanamic acid and meloxicam. A simple and rapid RP-HPLC method for simultaneous determination and quantification of verapamil and NSAIDs was developed and validated. The mobile phase constituted of acetonitrile: water (55:45) whose pH was adjusted at 2.7 and pumped at a flow rate of 2.0 mL $min^{-1}$ at 230 nm. The proposed method is simple, precise, accurate, low cost and least time consuming for the simultaneous determination of verapamil and NSAIDs which can be effectively applied for the analysis of human serum.

A measuring system for determination of a cantilever beam support moment

  • Loktionov, Askold P.
    • Smart Structures and Systems
    • /
    • 제19권4호
    • /
    • pp.431-439
    • /
    • 2017
  • This investigation is aimed to develop a model of experimental-computation determination of a support moment of a cantilever beam loaded with concentrated force at its end including the optimal choice of coordinates of deflection data points and parameters of transformation of deflection data in case of insufficient accuracy of the assignment of initial parameters (support settlement, angle of rotation of the bearing section) and cantilever beam length. The influence of distribution and characteristics of sensors on the cantilever beam on the accuracy of determining the support moment which improves in the course of transition from the uniform distribution of sensors to optimal non-uniform distribution is shown. On the basis of the theory of inverse problems the method of transformation reduction at numerical differentiation of deflection functions has been studied. For engineering evaluation formulae of uncertainty estimate to determine a support moment of a cantilever beam at predetermined uncertainty of measurements using sensors have been obtained.

Color Determination of Beef Rib Eye Using Near Infrared Spectroscopy

  • Kang, J.O.;Park, J.Y.;Choy, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권2호
    • /
    • pp.263-267
    • /
    • 2001
  • Beef samples of loin eye area from New Zealand, USA and three quality grades of Hanwoo were analyzed using near infrared spectrophotometer with reference values from laboratory optical Chromameter to determine effective spectrum range and mathematical treatment for determination of color values. $R^2s$ of prediction models were not improved much by calibrating with whole light range (400~2500 nm) compared to using visible range (400~1100 nm). Standard errors of calibration and prediction were influenced by possible bias due to sampling non-homogeneous sample sources. However, partial differentiation in the first order was more stable against sampling biases than second derivatives of the spectra. Lightness value was little different among the five sample sources of beef. Beef samples from USA were brighter and more reddish than beefs of Hanwoo or from New Zealand (p<0.05). Yellowness of USA beef was the highest followed by beef from New Zealand, which was also higher than Hanwoo beefs of three quality grades (p<0.05).