• Title/Summary/Keyword: Non-destructive X-ray analysis

Search Result 54, Processing Time 0.022 seconds

Possibility about Application and Interpretation of Surface Nondestructive X-ray Diffraction Method for Cultural Heritage Samples by Material (유형별 문화재 시료의 비파괴 표면 X-선 회절분석법 적용과 해석 가능성)

  • Moon, Dong Hyeok;Lee, Myeong Seong
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.287-301
    • /
    • 2019
  • Preservation of the original form is the principle for conservation, management and utilization of cultural heritages. Thus, non-destructive analysis of these samples are important field of the conservation science. In this study, examined the applicability of nondestructive surface X-ray diffraction analysis (ND-XRD) for cultural heritage by materials (rock specimen, jade stone, pigment painted specimen, earthen artifact, metal artifact). In result, all type of sample is recorded suitable X-ray diffraction patterns for identifying mineral composition in case of surface condition with adequate particle size and arrangement. And diffraction pattern is reflected surface information than matrix. Therefore, ND-XRD is thought to be applicable not only mineral identification but also interpretation of manufacturing technique and alteration trend about layered sample (in horizontally or vertically). Whereas some exceptional diffraction patterns were recorded due to overlapping information on specific crystal planes. It caused by skip the sample treatment (powdering and randomly orientation). It could be advantageously used for mineral identification, such as preferred orientation of clay minerals. In contrast, irregular diffraction pattern caused by single crystalline effect is required careful evaluation.

Current Status of X-ray CT Based Non Destructive Characterization of Bentonite as an Engineered Barrier Material (공학적방벽재로서 벤토나이트 거동의 X선 단층촬영 기반 비파괴 특성화 현황)

  • Diaz, Melvin B.;Kim, Joo Yeon;Kim, Kwang Yeom;Lee, Changsoo;Kim, Jin-Seop
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.400-414
    • /
    • 2021
  • Under high-level radioactive waste repository conditions, bentonite as an engineered barrier material undergoes thermal, hydrological, mechanical, and chemical processes. We report the applications of X-ray Computed Tomography (CT) imaging technique on the characterization and analysis of bentonite over the past decade to provide a reference of the utilization of this technique and the recent research trends. This overview of the X-ray CT technique applications includes the characterization of the bentonite either in pellets or powder form. X-ray imaging has provided a means to extract grain information at the microscale and identify crack networks responsible for the pellets' heterogeneity. Regarding samples of pellets-powder mixtures under hydration, X-ray CT allowed the identification and monitoring of heterogeneous zones throughout the test. Some results showed how zones with pellets only swell faster compared to others composed of pellets and powder. Moreover, the behavior of fissures between grains and bentonite matrix was observed to change under drying and hydrating conditions, tending to close during the former and open during the latter. The development of specializing software has allowed obtaining strain fields from a sequence of images. In more recent works, X-ray CT technique has served to estimate the dry density, water content, and particle displacement at different testing times. Also, when temperature was added to the hydration process of a sample, CT technology offered a way to observe localized and global density changes over time.

Ultrasonic Inspection Technology of Defect Detection of Solid Propellant Rocket Motor (초음파를 이용한 고체 추진제 추진기관의 결함 검출 기법)

  • Na Sung-Youb
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.239-245
    • /
    • 2006
  • Ultrasonic inspection method is more profitable than X-ray radiographic inspection in cost and effect of defect detection such as dis-bond, damage, and it does'nt need special constructions and can be possible real time inspection with safety. This report explains the experiment and analysis of ultrasonic property of solid propellant and the inspection methods of propellant/liner dis-bond by inside or outside inspection, and of propellnat micro crack by damage. At result, ultrasonics has big attenuation$(6\sim8db/cm)$ in solid propellant, and it. can be possiblle to detect the defect of propellant/liner dis-bond by inside or outside inspection. And also it can be possible to detect the propellant micro crack caused by damage by using ultrasonic attenuation.

  • PDF

Setting Time Evaluation on Cement Paste with Retarder Using Non-Destructive Measurements (비파괴 측정법을 이용한 지연제 첨가 시멘트 페이스트의 응결 평가)

  • Ahn, Yu-Rhee;Jun, Yu-Bin;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.48-56
    • /
    • 2022
  • Controlling the setting time of cementitious materials is one of the most important factors in securing early-age performance of concrete structures. Recently, the use of retarding admixtures, which enable the inhibition of some hydration products to control the securing time due to average temperature rise is suggested. Although various non-destructive evaluation methods have been proposed to evaluate cement hydration and hardening of cement-based materials to overcome the limitations of Vicat needle test, experimental research is still required to use the non-destructive evaluation method with added retarding admixtures. In this study, measurements of electrical resistivity and ultrasonic wave velocity in early-aged cement pastes were performed according to the addition of retarding admixture(tartaric acid). The setting time of the cement pastes was evaluated by obtained rising time of the both non-destructive measurements. As a result, the possibility of evaluating the setting delay in cement pastes was confirmed through comparative analysis with the initial and final setting times by Vicat test. In addition, X-ray diffraction results at the rising time of electrical resistivity showed a key hydration product affecting the setting delay.

Failure Mechanism of Bendable Embedded Electronic Module Under Various Environment Conditions (Bendable 임베디드 전자모듈의 손상 메커니즘)

  • Jo, Yun-Seong;Kim, A Young;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.31 no.5
    • /
    • pp.59-63
    • /
    • 2013
  • A bendable electronic module has been developed for a mobile application by using a low-cost roll-to-roll manufacturing process. In flexible embedded electronic module, a thin silicon chip was embedded in a polymer-based encapsulating adhesive between flexible copper clad polyimide layers. To confirm reliability and durability of prototype bendable module, the following tests were conducted: Moisture sensitivity level, thermal shock test, high temperature & high humidity storage test, and pressure cooker tester. Those experiments to induce failure of the module due to temperature variations and moisture are the experiment to verify the reliability. Failure criterion was 20% increase in bump resistance from the initial value. The mechanism of the increase of the bump resistance was analyzed by using non-destructive X-ray analysis and scanning acoustic microscopy. During the pressure cooker test (PCT), delamination occurred at the various interfaces of the bendable embedded modules. To investigate the failure mechanism, moisture diffusion analysis was conducted to the pressure cooker's test. The hygroscopic characteristics of the encapsulating polymeric materials were experimentally determined. Analysis results have shown moisture saturation process of flexible module under high temperature/high humidity and high atmosphere conditions. Based on these results, stress factor and failure mechanism/mode of bendable embedded electronic module were obtained.

Conservation Treatment and Study on Manufacturing Techniques of Jija Chongtong Gun in the Middle of Joseon Dynasty (조선 중기 제작된 지자총통의 보존처리와 제작기법 연구 -동아대학교 석당박물관 소장 보물 지자총통을 중심으로-)

  • Nam Dohyeon;Park Younghwan;Lee Jaesung
    • Conservation Science in Museum
    • /
    • v.30
    • /
    • pp.23-46
    • /
    • 2023
  • The Jija Chongtong Gun, owned by Seokdang Museum of Dong-A University, is a tubedstyle heavy weapon of the battlefield in the mid-Joseon Dynasty and is the second largest firearm after Cheonja Chongtong. The original surface color of the Jija Chongtong Gun was obscured by foreign substances and therefore it was judged that its condition requires the conservation treatment. For stable conservation treatment, gamma ray and X-ray non-destructive transmission surveys was conducted to determine the internal structure and conservation condition. And the component analysis on the material components and surface contaminants of Jija Chongtong Gun was conducted by utilizing the p-XRF component analysis, SEM-EDS component analysis, and XRD analysis. As a result of the gamma-ray and X-ray non-destructive transmission investigation, a large amount of air bubbles was observed inside Jija Chongtong Gun, and the part that appeared to be a chaplet by visual observation was not identified. As a result of gamma-ray and p-XRF component analysis, it was confirmed that Jija Chongtong Gun was bronze made of copper (Cu), tin (Sn), and lead (Pb) alloy. As a result of surface analysis of foreign substances using SEM-EDS, it was confirmed that the main components of white foreign substances were calcium (Ca), sulfur (S), and titanium (Ti). Titanium was presumed to be titanium dioxide (TiO2), the main component of white correction fluid. The red foreign substance was confirmed to contain barium (Ba) as its main ingredient, and was presumed to be barium sulfate (BaSO4), an extender pigment in paint. White and red contaminants, mainly composed of titanium and barium, are presumed to have been deposited on the surface in recent years. The yellow foreign substances were confirmed to be aluminum (Al) and silicon (Si), and were presumed to have originated from soil components. As a result of SEM-EDS and XRD component analysis, the white foreign substance was confirmed to be gypsum (CaS). Based on the results of component analysis, surface impurities were removed, stabilization treatment, and strengthening treatment were performed. During the conservation process, unknown inscriptions Woo (右), Byeong (兵), Sang (上), and Yi (二) were discovered through a portable microscope and precise 3D scanning. In addition, the carving method, depth, and width of the inscription were measured. Woo Byeong Sang is located above Happo Fortress in Changwon, and Yi can be identified as the second hill.

Analysis of Magnetic Multi-layers by RBS and PIXE (후방산란법(RBS)/양성자 여기 X-선 방출법(PIXE)을 이용한 다층자성박막의 두께 및 조성 정량분석)

  • 송종한;김태곤;전기영;황정남;신윤하;김영만;장성호;김광윤
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.6
    • /
    • pp.272-277
    • /
    • 2001
  • A spin valve structure of Ta/NiFe/CoFe/Cu/CoFe/Ru/CoFe/FeMn/Ta which has a synthetic antiferromagnet (CoFe/Ru/CoFe), was fabricated by using a magnetron sputtering system. The thickness and composition of magnetic free and pinned layers affect the magnetic properties such as exchange interaction strength of each layer and so on. Even though Rutherford Backscattering Spectrometry (RBS) has advantages of quantitative and non-destructive analysis, it is almost impossible to determine the thickness and composition of magnetic thin films using lBS because of its poor mass resolution for a higher atom number (Z>20). In this study, quantitative analysis of the element composition and thickness for the spin valve sample was performed by combining both Proton Induced X-ray Emission Spectrometry (PIXE), which is one of element specific analysis techniques, and grazing-exit RBS with a highly improved depth resolution and absolute quantitative analysis. For the quantitative analysis, standardization of PIXE was carried out with NiFe, CoFe, and FeMn layers, which are one of constituent layers of spin valve films. Through PIXE standardization and the aid of PHE experimental results of the spin valve sample, ire overlapped signal in a grazing-exit RBS spectrum were successfully resolved and the thickness of the Ru layer was determined with a resolution of ∼1 .

  • PDF

Discrimination of Geographical Origin for Herbal Medicine by Mineral Content Analysis with Energy Dispersive X-Ray Fluorescence Spectrometer (에너지분산형 X-선 형광분석기를 이용한 한약재의 무기질 분석 및 이에 의한 원산지 판별)

  • Jeong, Myeong-Sil;Lee, Soo-Bok
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.135-140
    • /
    • 2008
  • In this study, the macromineral content ratios of four herbal medicine samples(Saposhnikoviae Radix, Bupleuri Radix, Cnidii Rhizoma, and Astragali Radix) were analyzed to discriminate their geographical origins using an energydispersive x-ray fluorescence (EDXRF) technique. EDXRF is a rapid, non-destructive, and multi-elemental analysis technique. Initially, samples of both domestic and imported herbal medicines were pulverized, and then their macromineral contents, including P, S, K, and Ca, were analyzed using EDXRF. For the discrimination of their geographical origins, canonical discriminant analysis was carried out based on the estimated macromineral relative content ratios of the samples. According to the results, the discrimination accuracies were as follows: 93.3% for Saposhnikoviae Radix, 95.7% for Bupleuri Radix, 98.8% for Cnidii Rhizoma, and 87.5% for Astragali Radix. Overall, the results imply that this technique could be used as a standard method, to discriminate their geographical origins between domestic and imported herbal medicines.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

A study on a silicon surface modification by $CHF_3/C_2F_6$ reactive ion etching ($CHF_3/C_2F_6$ 반응성이온 건식식각에 의한 실리콘 표면의 변형에 관한 연구)

  • Park, Hyeong-Ho;Gwon, Gwang-Ho;Gwak, Byeong-Hwa;Lee, Su-Min;Gwon, O-Jun;Kim, Bo-U;Seong, Yeong-Gwon
    • Korean Journal of Materials Research
    • /
    • v.1 no.4
    • /
    • pp.214-220
    • /
    • 1991
  • The effects of $SiO_2$ reactive ion etching (RIE) in $CHF_{3/}C_2F_6$ on the surface properties of the underlying Si substrate were studied by X-ray photoelectron spectroscopy(XPS) and secondary ion mass spectrometry(SIMS) techniques. Angle-resolved XPS analysis was carried out as non-destructive depth profile one for investigating the chemical bonding states of silicion, carbon, oxygen and fluorine. The residue layer consists of C-F polymer. O-F bond was found on the top of the polymer layer and Si-O, Si-C and Si-F bonds were detected between Si substrate and polymer film. A 60nm thick damaged layer of silicon surface mainly contains carbon and fluorine.

  • PDF