• 제목/요약/키워드: Non-contact system

검색결과 764건 처리시간 0.031초

윙립 두께 측정용 비접촉식 검사 시스템에 관한 실험적 연구 (Experimental Study on Non-contact Type Inspection System for Wing Rib Thickness Measurement)

  • 이인수;김해지;안명섭
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.104-110
    • /
    • 2014
  • This paper presents a non-contact inspection system for automatically measuring the thickness of an aircraft wing rip product. In order to conduct the inspection of the wing rib thickness automatically, a non-contact laser displacement sensor, end-effector, and a robot were selected for use. The non-contact type inspection system was evaluated by measuring the measurement deviation of the rotation direction of a C-type yoke end-effector and the transfer direction of a V-slim end-effector. In addition, the non-contact inspection system for wing rib thickness measurements was validated through thickness measurements of a web, flange, and stiffener.

대형 유연박판 회전이송용 비접촉 파지시스템 설계 (Non-Contact Pick-up System for Turning Large Flexible Thin Sheets)

  • 김준현;안성욱;이세진
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.435-442
    • /
    • 2014
  • This paper describes an improved design model that can be used to configure a non-contact pneumatic device to turn a large sheet at the in-line system. For rotational moving in the conveyor system, the conventional method is to turn the system itself. The improved non-contact pick-up system mainly uses 8 pairs of L-shaped latches and 12 swirl type heads. It is positioned above the upward air flow table. This system performs the non-contact gripping and side-edge contact support in the vertical and rotational directions to hold the self-weight of a large flat sheet. A non-contact air head can exert a sufficient gripping ability at 4N lower than the standard working pressure. The side latches support 60% of the lifting force required. Through structural and flow analysis, the working conditions were simultaneously considered in accordance with the deflection and flatness of the glass.

비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성 (Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor)

  • 전화봉;윤정원;김성홍
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

Non-contact Palmprint Attendance System on PC Platform

  • Wu, Yuxin;Leng, Lu;Mao, Huapeng
    • Journal of Multimedia Information System
    • /
    • 제5권3호
    • /
    • pp.179-188
    • /
    • 2018
  • In order to overcome the problems of contact palmprint recognition, a non-contact palmprint recognition system is developed on personal computer (PC) platform. Three methods, namely "double-line-single-point" (DLSP), "double-assistant-crosshair" (DAC) and "none-assistant-graphic" (NAG), are implemented for the palmprint localization to solve the severe technical challenges, including the complex background, variant illuminations, uncontrollable locations and gestures of hands. In NAG, hand segmentation and the cropping of region of interest are performed without any assistant graphics. The convex hull contour of hand helps detect the outside contour of little finger as well as the valley bottom between thumb and index finger. The three methods of palmprint localization have good operating efficiency and can meet the performance requirements of real-time system. Furthermore, an attendance system on PC platform is designed and developed based on non-contact palmprint recognition.

3차원 측정기용 비젼프로브 운용시스템 개발 (Development of Managing System of Vision Probe for CMM)

  • 박재성;박희재;김구영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.501-505
    • /
    • 1996
  • In CMM system, a contact probe is not applicable to very small, or flexible elements. There is need to develop non-contact probes of CCD camera. But non-contact probes have some technical problems, including distortion, user interface and time delay. This development gives the foundation of the non-contact probe system and some useful solutions for the problems. The results can be useful for industry application.

  • PDF

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

POWER TRANSMISSION CHARACTERISTICS OF FEASIBLE NON-CONTACT PICK-UP COIL COUPLED TO HIGH-FREQUENCY POWER SUPPLY SYSTEM

  • Kuroda, Mitsuyoshi;Tsuda, Masanori;Okuno, Atsushi;Gamage, Laknath;Mutsuo, Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.447-451
    • /
    • 1998
  • This paper conducts a study on a non-contact power delivering system using high-frequency inverter with the purpose of discussing the non-contact electric power transmission characteristics through circuit analysis, magnetic analysis and feasible experiments. In this power delivering scheme, various properties pertaining to the non-contact transformer of the power system such as the design, the core depth, core material, primary side frequency etc. are considered with a view of improving the non-contact power dilivery to the secondary.

  • PDF

Development of a Non-contact Input System Based on User's Gaze-Tracking and Analysis of Input Factors

  • Jiyoung LIM;Seonjae LEE;Junbeom KIM;Yunseo KIM;Hae-Duck Joshua JEONG
    • 한국인공지능학회지
    • /
    • 제11권1호
    • /
    • pp.9-15
    • /
    • 2023
  • As mobile devices such as smartphones, tablets, and kiosks become increasingly prevalent, there is growing interest in developing alternative input systems in addition to traditional tools such as keyboards and mouses. Many people use their own bodies as a pointer to enter simple information on a mobile device. However, methods using the body have limitations due to psychological factors that make the contact method unstable, especially during a pandemic, and the risk of shoulder surfing attacks. To overcome these limitations, we propose a simple information input system that utilizes gaze-tracking technology to input passwords and control web surfing using only non-contact gaze. Our proposed system is designed to recognize information input when the user stares at a specific location on the screen in real-time, using intelligent gaze-tracking technology. We present an analysis of the relationship between the gaze input box, gaze time, and average input time, and report experimental results on the effects of varying the size of the gaze input box and gaze time required to achieve 100% accuracy in inputting information. Through this paper, we demonstrate the effectiveness of our system in mitigating the challenges of contact-based input methods, and providing a non-contact alternative that is both secure and convenient.

USN 기술 기반의 비접촉 식물 생장 측정 시스템 구현 (Implementation of Non-contact Plant Growth Measurement System based on USN Technologies)

  • 석진원;유인태
    • 한국컴퓨터정보학회논문지
    • /
    • 제15권10호
    • /
    • pp.137-145
    • /
    • 2010
  • 본 논문은 USN(Ubiquitous Sensor Network) 기술 기반의 적외선 센서를 사용한 비접촉식 식물 생장 측정 시스템을 제안한다. 제안된 시스템은 식물 생장을 측정할 때 식물의 생장 피해를 줄이기 위하여 비접촉 센서를 사용하였다. 이 시스템은 직경, 단면적, 비대 형상과 같은 식물 생장 요소를 실시간 비접촉 방식으로 측정할 수 있다. 측정된 데이터는 센서 네트워크 기술을 사용하여 원격 서버까지 전송되고, 서버에서 저장 및 분석되며, 최종적으로 분석된 데이터는 사용자에게 제공될 수 있도록 구성하였다. 본 논문에서 제안된 식물 생장 측정시스템은 측정 방식과 장치에 비접촉 적외선 센서를 사용하여 설계 및 구현을 하였다. 그리고 시스템의 성능은 필드에서 측정 실험을 통하여 검증해 보았다.

광촉침법에 의한 비접촉 3차원 형상측정에 관한 연구 (A Study on Non-contact Measurement of 3D-Objects by Optical Probe Method)

  • 강영준;신성국;삼호융지
    • 한국정밀공학회지
    • /
    • 제12권4호
    • /
    • pp.119-126
    • /
    • 1995
  • This paper presents a non-contact measuring system using one point measuring method to measure surface profiles of dies and clay models for practical use in the field of production engineering. The system has a laser beam probe similar to a measuring probe in a contact measuring system and CCD linear sensor used to detect 300mm measurement range, displacement of measured surfaces, from an origin. There is no mechanical interference between this measuring system and a measured surface in this system. In this measuring system, it was needed 500-600ms including data processing time to measure one point. The experiments showed that the standard deviation was 800 .mu.m and the reproducibility was also 100-210 .mu. m.

  • PDF