• Title/Summary/Keyword: Non-contact glass

Search Result 70, Processing Time 0.027 seconds

Ohmic Contact Effect and Electrical Characteristics of ITO Thin Film Depending on SiOC Insulator (SiOC 절연박막 특성에 의존하는 ITO 투명박막의 전기적인 특성과 오믹접합의 효과)

  • Oh, Teresa
    • Korean Journal of Materials Research
    • /
    • v.25 no.7
    • /
    • pp.352-357
    • /
    • 2015
  • To research the characteristics of ITO film depending on a polarity of SiOC, specimens of ITO/SiOC/glass with metal-insulator-substrates (MIS) were prepared using a sputtering system. SiOC film with 17 sccm of oxygen flow rate became a non-polarity with low surface energy. The PL spectra of the ITO films deposited with various argon flow rates on SiOC film as non-polarity were found to lead to similar formations. However, the PL spectra of ITO deposited with various argon flow rates on SiOC with polarity were seen to have various features owing to the chemical reaction between ITO and the polar sites of SiOC. Most ITO/SiOC films non-linearly showed the Schottky contacts and current increased. But the ITO/SiOC film with a low current demonstrated an Ohmic contact.

Measurement of a Shape of Glass Using the Hologram Optical System

  • Lee, Young-Chon;Youn, Sang-Pil;Ryu, Young-Kee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.53.2-53
    • /
    • 2001
  • The Non-Contact Optical Sensor using the Hologram Laser for CD Pickup was developed to measure a shape of transparent objects and shown a good performance. Therefore the problems caused by the contact sensor are solved by using the Non-Contact Sensor. The Non-Contact Sensor has to move toward the objects and obtain the Focus Error Signal to measure a position of transparent objects. However, if the distance between the sensor and the object is shorter than the working distance of the objective lens, the sensor will be collided against the objects. In this paper we proposed a new algorithm to estimate the start position of the Focus Error Signal to solve the problems of collision between the sensor and the objects. In addition, we verified that the algorithm is free from the collision in the real time measurement.

  • PDF

Development of a Sensor Calibration to Enhance the Performance of a Non-contact Laser Optical Sensor Unit (비접촉 레이저 광센서의 성능 향상을 위한 센서보정에 관한 연구)

  • Seo, Pyeong-Won;Ryu, Young-Kee;Oh, Choon-Suk;Byun, Jong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.579-581
    • /
    • 2006
  • Flat panel image display devices such as TFT LCD and PDP have required more large area and high quality control components. To control the qualities of the components, measurements of the flatness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens. The temperature of the sensor body is controlled by TEC(Thermoelectric Cooler) to maintain the same wavelength of the diode laser. In this research, we proposed the calibration scheme to make sensor real time measuring sensor. From the experimental results we see that the proposed sensor unit can measure the position of the glass surface in rial time.

  • PDF

Properties of Glass-Ceramics in the System CaO-TiO2-SiO2 with the Additives of Al2O3, ZrO2 and B2O3 for Use in the Solid Oxide Fuel Cells.

  • Lee, Jun-Suk;Park, Min-Jin;Shin, Hyun-Ick;Lee, Jae-Chun
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.336-340
    • /
    • 1999
  • Glasses in the system $CaO-TiO_2-SiO_2-Al_2O_3-ZrO_2-B_2O_3$ were investigated to find the glass seal compositions suitable for use in the planar solid oxide fuel cell (SOFC). Glass-ceramics prepared from the glasses by one-stage heat treatment at $1,000^{\circ}C$ showed various thermal expansion coefficients (i,e., $8.6\times10^{-6^{\circ}}C^{-1}$ to $42.7\times10^{-6^{\circ}}C^{-1}$ in the range 25-$1,000^{\circ}C$) due to the viscoelastic response of glass phase. The average values of contact angles between the zirconia substrate and the glass particles heated at 1,000-$1,200^{\circ}C$ were in the range of $131^{\circ}\pm4^{\circ}$~$137^{\circ}\pm9^{\circ}$, indicating that the glass-ceramic was in partial non-wetting condition with the zirconia substrate. With increasing heat treatment time of glass samples from 0.5 to 24 h at $1,100^{\circ}C$, the DC electrical conductivity of the resultant glass-ceramics decreased from at $800^{\circ}C$. Isothermal hold of the glass sample at $1100^{\circ}C$ for 48h resulted in diffusion of Ca, Si, and Al ions from glass phase into the zirconia substrate through the glass/zirconia bonding interface. Glass phase and diffusion of the moving ion such as $Ca^{2+}$ in glass phase is responsible for the electrical conduction in the glass-ceramics.

  • PDF

Development of a noncontact optical sensor for measuring the shape of transparent plates (평판 투명 물체의 형상측정을 위한 비접촉식 광센서 개발)

  • 윤상필;유영기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.214-214
    • /
    • 2000
  • This paper deals with the non contact optical sensor to measure the shape of transparent plates such as glass panel of LCD(Liquid Crystal Display). The conventional methods to obtain the shape or thickness of a transparent plates are contact type sensor such as LVOT(Linear Variable Differential Transformer). Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition, the high temperature glass casting makes the size of sensor body changed. These reasons makes the sensor degraded. In this paper, to overcome these problem, we proposed a low cost noncontact optical sensor this is composed of the Hologram laser unit of a CD-Pickup and a plastic lens. To evaluate the performance of the proposed optical sensor, a series of experiments were performed for various measurement condition. Based upon observation of the experimental result, the developed sensor shows good result for measuring the shape of transparent plates.

  • PDF

Development of Air-floating Conveyor System for FPD (FPD용 공기부상 이송컨베이어 시스템 개발)

  • Lho, Tae-Jung;Lee, Wook-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • The CRT(Cathode Ray Tube) displays have been substituted for FPDs(Flat Panel Displays) such as LCD(Liquid Crystal Display) and PDP(Plasma Display Panel) because they have a convex surface, large volume and heavy weight. The productivity of FPDs is greatly dependent on the area of thin glass panel with $0.6{\sim}0.8mm$ thickness because FPDs are manufactured by cutting a large-scaled thin glass panel with patterns to the required product dimensions. So FPD's industries are trying to increase the area of thin glass Panel. Through FEM(Finite Element Method) analysis and fluid analysis, we developed an non-contact and air-floating conveyor system which consists of transport-module, distributor, horizontal/vertical changer and controller for the 7th generation glass panel (2,200mm in width, 1,870mm in length and 0.7mm in thickness). The design technology developed in this study can be effectively applied to a conveyor system for a larger-scaled thin glass panel.

LCD 제조용 스퍼터링 장비의 비접촉식 유리평판 이송장치에 대한 수치적 연구

  • Gang, U-Jin;Im, Ik-Tae;Kim, U-Seung
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.149-156
    • /
    • 2007
  • Non-contact transportation of the large-sized glass plate using air-cushion is considered for sputtering system of LCD panel. The Argon gas from second gas injection holes is injected to levitate and transport the glass plate. Low maximum pressure and uniform pressure distribution on the bottom surface of the glass plate must be maintained for stable levitation and transportation of the glass plate. Therefore, the analysis of fluid flow between the glass plate and the air-pad is numerically performed for varying space between the injection holes in this study. The pressure uniformity on the bottom surface of the glass plate is evaluated for overall glass plate. The distance between the injection holes must be designed below 90 mm for obtaining the low maximum pressure and uniform pressure distribution.

  • PDF

A comparison and analysis of laser sensors for measuring the flatness and thickness of flat display glass (평판 디스플레이용 유리의 평탄도 및 두께 측정을 위한 레이저 센서의 비교 분석)

  • Kim, Soon-Chul;Han, Chang-Ho;Oh, Chun-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1079-1080
    • /
    • 2008
  • To improve productivity of TFT-LCD and PDP, it is required that the inspection system of flat glass should be established. It is composed of robot arms, base table, and laser sensors. This paper focuses on three non-contact laser sensors. After testing three laser sensors, LG-G30 is selected.

  • PDF

Flat Panel Display Deflection Analysis Considering Lift Force in Non-Contact Flat Panel Display Conveyer System (비접촉 평판 디스플레이 이송장치에서 양력을 고려한 평판 디스플레이의 처짐 해석)

  • Hwang, Sung-Hyen;Choi, Hyeon-Chang;Lho, Te-Jung;Son, Te-Yong;Park, Bum-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.5
    • /
    • pp.451-457
    • /
    • 2008
  • Flat Panel Display(FPD) is widely used a video display terminals to consumer products of LCD and PDP. The contamination and damage were affected by using the previous contact conveyor's method. In this paper, it analyzes the FPD deflection to develop the non-contact FPD transfer process using lift force. Each conveyor's equipment is called a horizontal conveyor, vertical conveyor and robot pick-up equipment. As result of an analysis of FPD panel's deflection, a robot pick-up equipment has performed according to under the present conditions like panel's weight and loaded glass to move FPD panel from one place to other places properly. Results of the analysis showed 0.474 mm, 0.424 mm and 1.237 mm. Those values are lower than a predicted optimum values : 2 mm for both horizontal and vertical conveyers; 5 mm for robot pick-up equipment. Therefore, those results verify each equipment have safety and reliability.

Determination and Analysis of Interface Heat Transfer Coefficients in Hot Forming of Ti-6Al-4V (Ti-6Al-4V 합금의 열간성형에 대한 계면열전달계수의 결정 및 분석)

  • 염종택;임정숙;박노광;신태진;황상무;홍성석
    • Transactions of Materials Processing
    • /
    • v.12 no.4
    • /
    • pp.370-375
    • /
    • 2003
  • Determination of the interface heat transfer coefficient was investigated in non-isothermal bulk forming of glass-coated Ti-6Al-4V. FE analysis and experiments were conducted. Equipment consisting of AISI Hl3 die was instrumented with thermocouples located at sub-surface of the bottom die. Die temperature changes were investigated in related to the process variables such as reduction, lubricant and initial die temperature. The calibration approach based on heat conduction and FE analysis using an inverse algorithm were used to evaluate the interface heat transfer between graphite-lubricated die and glass-coated workpiece. The coefficients determined were affected mainly by the contact pressure. The validation of the coefficients was made by the comparison between experimental data and FE analysis results.