• Title/Summary/Keyword: Non-absorbable

Search Result 56, Processing Time 0.024 seconds

Granuloma Formation, a Rare Complication after PDO Threads Lifting, and Adjuvant Treatment Using Dual-Frequency Ultrasound (LDM®-MED)

  • Hong, Seok Won;Park, Eun Soo
    • Medical Lasers
    • /
    • v.8 no.1
    • /
    • pp.35-38
    • /
    • 2019
  • Thread-lifting is a minimally invasive procedure that shows good results and fewer complications as compared with those results and complications of standard surgery. Many procedures and techniques have been developed to create a younger appearance of facial/neck skin for aging people, and the demand for an improved aesthetic appearance is increasing. Since the incidence of side effects is much less than that of non-absorbable threads, which can lead to complications such as foreign body reactions, polydioxanone (PDO) threads are predominantly used for face lift procedures. A 66-year-old woman presented to our clinic with inflamed palpable masses. She had undergone a face lift with absorbable threads in our clinic 5 months previously. Excisional biopsy was performed with the patient under local anesthesia. During the operation, any threads were not detected and there was both fibrotic scar tissue and granulomatous tissue. For effectively promoting healing and managing the scars, treatment with LDM®-MED was performed on the day after surgery. The treatment was performed according to the author's protocol. Although foreign body granuloma as a complication after using non-absorbable thread types have been previously reported, it is relatively rare to find this type of complication after using absorbable thread. In this report, we present a case in which a 66-year-old female with foreign body granuloma after undergoing a face lift using absorbable threads was treated with the application of dual-frequency ultrasound, which promoted wound healing.

Rigid Fixation using Bioabsorbable Mesh and Screws in Facial Bone Fracture (흡수성 망상판과 나사를 이용한 안면골절의 견고정법)

  • Shin, Dong-Hyeok;Kim, Deok-Jung;Kim, Soo-Young;Hwang, Eun-A;Choi, Hyun-Gon;Kim, Soon-Heum;Uhm, Ki-Il
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.717-720
    • /
    • 2010
  • Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.

Improvement of absorption characteristics by insert devices in a vertical tube (수직관내 삽입기구에 의한 흡수특성의 향상)

  • 김병주;신광섭;문형석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.466-474
    • /
    • 1998
  • In the present study, the improvement of absorption characteristics by installing insert devices, such as spring and wire screen, inside the vertical tube absorber were studied experimentally. Momentum, heat and mass transfer rate in the absolution process of smooth bare tube, smooth tube with spring-insert, and with wire screen-insert were compared and analysed in range of film Reynolds number of 40∼200. The improvement of heat transfer rate by spring-insert and screen-insert were remarkable especially in the low Reynolds number region. As the mesh number increased in screen-insert and as the pitch decreased in spring-insert, Nusselt and Sherwood number increased. Degradation of mass transfer by non-absorbable gas showed similar qualitative trends regardless of the insert type.

  • PDF

Treatment of Achilles Tendon Rupture with Absorbable Suture (흡수성 봉합사를 이용한 아킬레스건 파열의 치료)

  • Kang, Chan;Hwang, Deuk-Soo;Hwang, Jung-Mo;Song, Jae-Hwang;Shin, Byung-Kon;Park, Jong-Hwa
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.3
    • /
    • pp.115-118
    • /
    • 2014
  • Purpose: The purpose of this study is to report on the result of repairing Achilles tendon using absorbable suture under nerve block. Materials and Methods: We retrospectively reviewed 20 patients with acute Achilles tendon rupture who were followed up for at least six months after the operation. We repaired Achilles tendon using two absorbable sutures using the Krackow technique for the proximal stump and the Kessler technique for the distal stump. A programmed postoperative management including non-weight bearing with a short leg cast for four weeks after the operation was applied for all patients. We evaluated clinical results using American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, visual analogue scale (VAS) for satisfaction, range of motion of ankle, functional recovery rate, and the starting time of single heel raise. Results: The mean VAS score for satisfaction and AOFAS score was 9.2 and 93.0, respectively. The affected ankle showed a mean dorsiflexion rate of 90% and plantar-flexion rate of 94% compared to the uninjured side. The single heel raise could start at a mean of 3.5 months after the operation. Conclusion: Treatment of Achilles tendon rupture with absorbable suture material using the hybrid suture technique of proximal Krackow and distal Kessler showed sufficient stability and minimal chronic inflammatory reaction.

Comparing Complications of Biologic and Synthetic Mesh in Breast Reconstruction: A Systematic Review and Network Meta-Analysis

  • Young-Soo Choi;Hi-Jin You;Tae-Yul Lee;Deok-Woo Kim
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.3-9
    • /
    • 2023
  • Background In breast reconstruction, synthetic meshes are frequently used to replace acellular dermal matrix (ADM), since ADM is expensive and often leads to complications. However, there is limited evidence that compares the types of substitutes. This study aimed to compare complications between materials via a network meta-analysis. Methods We systematically reviewed studies reporting any type of complication from 2010 to 2021. The primary outcomes were the proportion of infection, seroma, major complications, or contracture. We classified the intervention into four categories: ADM, absorbable mesh, nonabsorbable mesh, and nothing used. We then performed a network meta-analysis between these categories and estimated the odds ratio with random-effect models. Results Of 603 searched studies through the PubMed, MEDLINE, and Embase databases, following their review by two independent reviewers, 61 studies were included for full-text reading, of which 17 studies were finally included. There was a low risk of bias in the included studies, but only an indirect comparison between absorbable and non-absorbable mesh was possible. Infection was more frequent in ADM but not in the two synthetic mesh groups, namely the absorbable or nonabsorbable types, compared with the nonmesh group. The proportion of seroma in the synthetic mesh group was lower (odds ratio was 0.2 for the absorbable and 0.1 for the nonabsorbable mesh group) than in the ADM group. Proportions of major complications and contractures did not significantly differ between groups. Conclusion Compared with ADM, synthetic meshes have low infection and seroma rates. However, more studies concerning aesthetic outcomes and direct comparisons are needed.

A comparative study of the clinical effects of PRP and non-absorbable membrane in the treatment of mandibular class II furcations (하악 2급 이개부 병변 치료시 비흡수성 차폐막과 혈소판 농축 혈장의 임상적 효과에 대한 비교 연구)

  • Kim, Chang-Ho;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.509-522
    • /
    • 2004
  • This study was performed to compare the clinical effectiveness of two regenerative techniques for class II furcation involvements in human: a combination of bone grafts with PRP vs. GTR with bone grafts. The e-PTFE group was treated with non-absorbable membrane and bone grafts, the PRP group was treated with PRP and bone grafts Pocket depth, clinical attachment level, and gingival recession were measured at baseline and postoperative 6 months. Vertical and horizontal furcation depth were measured by re-entry surgeries at 6 months post-treatment Both groups were statistically analyzed by Wilcoxon signed Ranks Test & Mann-whitney Test using SPSS program (5% significance level). The results were as follows: 1. The change of pocket depth, clinical attachment level, vertical furcation depth and horizontal furcation depth in both groups was decreased significantly at 6 months than at baseline. (p<0.05) 2. The change of gingival recession in both groups was increased significantly at 6 months than at baseline. (p<0.05) 3. The change of alveolar crest absorption in both groups was increased at 6 months than at baseline but there were no statistically significant differences. 4. The change of pocket depth, clinical attachment level, vertical furcation depth and horizontal furcation depth in both groups was increased significantly at 6 months, but there were no statistically or clinically significant differences with both groups. 5. The change of gingival recession and alveolar crest absorption in both groups was increased at 6 months, but there were no statistically or clinically significant differences with both groups. In conclusion, the use of bone graft with PRP or GTR technique improved clinical index of the soft and hard tissue in mandibular class II furcation involvement but there were no statistically or clinically significant differences between bone graft with PRP and GTR technique.

Ventriculoperitoneal Shunt without Hair Shaving Using Absorbable Suture Materials

  • Lee, Yun Ho;Kwon, Young Sub;Cho, Jin Mo
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.120-124
    • /
    • 2021
  • Objective : Infection is one of most devastating complications in ventriculoperitoneal (VP) shunt surgery. Preoperative hair removal has traditionally been performed to reduce infectious complications. We performed VP shunt surgeries and evaluated the prevalence of infection in patients who were shaved and those who were unshaven. Methods : A retrospective analysis was conducted of 82 patients with hydrocephalus of various pathologies who underwent VP shunt surgery, with or without having the head shaved, between March 2010 and March 2017. For patients in the non-shaved group (n=36), absorbable suture materials were used for wound closure, and Nylon sutures or staples were used in the shaved group (n=46). We evaluated the infection outcomes of patients in the two groups. Results : There was no difference in the average age of patients in the two groups. In the non-shaved group, there were no infections, while two patients in the shaved group required revision because of shunt infection. Conclusion : Non-shaved shunt surgery may be safe and effective, with no increase of infection rate. We recommend that shunt procedures could be performed without shaving the hair, which may increase patients' satisfaction without increasing infection risk.

Inframammary Fold Creation in Breast Reconstruction (유방재건시 유방하 주름의 생성)

  • Lee, Hae Min;Ahn, Hee Chang;Choi, Seung Suk;Jo, Dong In;Byun, Tae Ho
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.231-236
    • /
    • 2005
  • Nowadays breast reconstruction with autologous tissues after radical mastectomy is commonly performed, and a natural inframammary fold in the reconstructed breast is considered to be an essential aspect of symmetrical breast shape and location. Total of 104 patients underwent breast reconstruction with free TRAM flap and formation of inframammary fold with free TRAM breast reconstruction was done in 79 patients. No suture fixation for inframammary fold were done in 19 patients. 27 patients(24.0%) were made of inframammary fold with absorbable suture, 52 patients (50.0%) underwent inframammary fold creation with nonabsorbable suture. There were 4 cases(16.0%) of displacement of reconstructed breast and 2 cases(8.0%) of partial disruption of inframammary fold in the group of no suture. There were 2 cases(7.4%) of displacement of reconstructed breast and 3 cases(11.1%) of partial disruption of inframmamary fold in the fixed group with absorbable suture. There was only 1 case(1.9%) of partial disruption of inframammary fold fixed with nonabsorbable suture group. Therefore, we could speculate that the reinforcement of ligamentous structure for making the definite inframammary fold is necessary, and the area of the inframammary fold should not be undermined in immediate breast reconstruction as much as possible in order to preserve the zone of adherence. If the fold is disrupted during the mastectomy, it should be re-created with the non-absorbable sutures. Nonabsorbable suture fixation seemed to be more stable than absorbable suture. Preoperative marking and design are very important to make the symmetrical shape and location of inframammary fold in both of immediate and delayed reconstruction of breasts.

Vessel Remodeling after Intima-to-Intima Contact Anastomosis

  • Yeo, Hyeonjung;Kim, Hyodong;Son, Daegu;Hong, Changbae;Kwon, Sun Young
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.95-100
    • /
    • 2017
  • Background Intima-to-intima microanastomotic vascular remodeling was explored, utilizing a polylactide-caprolactone absorbable vein coupler model (PAVCM), which was designed to simulate a non-absorbable counterpart system with the sole exception of being absorbable. Methods Six New Zealand white rabbits were used. After transection of the jugular vein, 2 PAVCMs were placed, 1 at each transected end. The stumps were slipped through the PAVCMs, and the venous wall was everted $90^{\circ}$ to achieve intima-to-intima contact. Reanastomosis of the transected jugular vein was performed bilaterally in 3 rabbits. In the other 3 rabbits, the jugular vein (20 mm) harvested from one side was interpositionally grafted to the jugular vein on the opposite side to ease the anastomotic tension. Patency testing, ultrasonography, and histologic assessments were conducted postoperatively at weeks 2, 4, 12, 16, 22, and 26. Results All anastomotic sites were patent, without stenosis, occlusion, or dilatation. In the histologic sections, immature endothelial regeneration was observed at week 2, which was completed by week 4. Regeneration of the tunica media was noted at week 12. Between week 22 and week 26, the tunica media fully regenerated and the coupler dissipated entirely. Conclusions Despite the absence of a coupler to act as an anastomotic buttress, the structure and function of all the vessels appeared normal, even histologically. These outcomes are true milestones in the development of an absorbable vein coupler.