• 제목/요약/키워드: Non-Uniformity

검색결과 582건 처리시간 0.026초

NON-UNIFORMITY CORRECTION- SYSTEM ANALYSIS FOR MULTI-SPECTRAL CAMERA

  • Park Jong-Euk;Kong Jong-Pil;Heo Haeng-Pal;Kim Young Sun;Chang Young Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.478-481
    • /
    • 2005
  • The PMU (Payload Management Unit) is the main subsystem for the management, control and power supply of the MSC (Multi-Spectral Camera) Payload operation. It is the most important function for the electro-optical camera system that performs the Non-Uniformity Correction (NUC) function of the raw imagery data, rearranges the data from the CCD (Charge Coupled Device) detector and output it to the Data Compression and Storage Unit (DCSU). The NUC board in PMU performs it. In this paper, the NUC board system is described in terms of the configuration and the function, the efficiency for non-uniformity correction, and the influence of the data compression upon the peculiar feature of the CCD pixel. The NUC board is an image-processing unit within the PMU that receives video data from the CEV (Camera Electronic Unit) boards via a hotlinkand performs non-uniformity corrections upon the pixels according to commands received from the SBC (Single Board Computer) in the PMU. The lossy compression in DCSU needs the NUC in on-orbit condition.

  • PDF

구리 CMP 공정변수 최적화를 위한 실험계획법(DOE) 연구 (A Study on DOE Method to Optimize the Process Parameters for Cu CMP)

  • 최민호;김남훈;김상용;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제18권1호
    • /
    • pp.24-29
    • /
    • 2005
  • Chemical mechanical polishing (CMP) has been widely accepted for the global planarization of multi-layer structures in semiconductor manufacturing. Copper has been the candidate metallization material for ultra-large scale integrated circuits (ULSIs), owing to its excellent electro-migration resistance and low electrical resistance. However, it still has various problems in copper CMP process. Thus, it is important to understand the effect of the process variables such as turntable speed, head speed, down force and back pressure are very important parameters that must be carefully formulated in order to achieve desired the removal rates and non-uniformity. Using a design of experiment (DOE) approach, this study was performed investigating the main effect of the variables and the interaction between the various parameters during CMP. A better understanding of the interaction behavior between the various parameters and the effect on removal rate, non-uniformity and ETC (edge to center) is achieved by using the statistical analysis techniques. In the experimental tests, the optimum parameters which were derived from the statistical analysis could be found for higher removal rate and lower non-uniformity through the above DOE results.

Spatial Compare Filter Based Real-Time dead Pixel Correction Method for Infrared Camera

  • Moon, Kil-Soo
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권12호
    • /
    • pp.35-41
    • /
    • 2016
  • In this paper, we propose a new real-time dead pixel detection method based on spatial compare filtering, which are usually used in the small target detection. Actually, the soft dead and the small target are cast in the same mold. Our proposed method detect and remove the dead pixels as applying the spatial compare filtering, into the pixel outputs of a detector after the non-uniformity correction. Therefore, we proposed method can effectively detect and replace the dead pixels regardless of the non-uniformity correction performance. In infrared camera, there are usually many dead detector pixels which produce abnormal output caused by manufactural process or operational environment. There are two kind of dead pixel. one is hard dead pixel which electronically generate abnormal outputs and other is soft dead pixel which changed and generated abnormal outputs by the planning process. Infrared camera have to perform non-uniformity correction because of structural and material properties of infrared detector. The hard dead pixels whose offset values obtained by non-uniformity correction are much larger or smaller than the average can be detected easily as dead pixels. However, some dead pixels(soft dead pixel) can remain, because of the difficulty of uncleared decision whether normal pixel or abnormal pixel.

연마불균일도에 영향을 미치는 패드 표면특성에 관한 연구 (The Effect of Pad Surface Characteristics on Within Wafer Non-uniformity in CMP)

  • 박기현;박범영;정재우;이현섭;정석훈;정해도;김형재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.38-39
    • /
    • 2005
  • We have investigated the effect of the pad surface characteristics such as roughness, groove density and wear of pad on within wafer non-uniformity(WIWNU) in chemical mechanical polishing(CMP). We found that WIWNU increases as pad surface roughness($R_{pk}$; Reduced peak height) increases in an early stage of polishing. But after polishing time goes to a certain extent, WIWNU decreases as uniformity of pad surface roughness. Also, groove of pad has effect on relative pad stiffness although original mechanical properties of pad are unchanged by grooving. WIWNU decreases as relative pad stiffness decreases. In addition, conditioning process causes non-uniform wear of pad during in CMP. The profile of pad wear has a significant effect on WIWNU.

  • PDF

디퓨저 타입 레큐퍼레이터 헤더에서 유동분배에 미치는 베인의 영향 (Effect of Vanes on Flow Distribution in a Diffuser Type Recuperator Header)

  • 정영준;김서영;김광호;곽재수;강병하
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.819-825
    • /
    • 2006
  • In a SOFC/GT (solid oxide fuel cell/gas turbine) hybrid power generation system, the recuperator is an indispensible component to enhance system performance. Since the expansion ratio to the recuperator core is very large, generally, the effective header design to distribute the flow uniformly before entering the core is crucial to guarantee the required performance. In the present study, we focus on the design of a diffuser type recuperator header with a 90 degree turn inlet port. To reduce the flow separation and recirculation flows, multiple horizontal vanes are used. The number of horizontal vanes is varied from 0 to 24. The air flow velocity is measured at 40 points just behind the core outlet by using a hot wire anemometer. Then, the flow non-uniformity is evaluated from the measured flow velocity. The experimental results showed that inlet air velocity did not effect on relative flow non-uniformity. According to increasing the number of horizontal vanes, flow non-uniformity reduced about $40{\sim}50%$ than without using horizontal vanes.

타코펄스 불균일성으로 인한 펄스개수측정방법 영향성 (Tacho Pulse Non-uniformity Effects on Pulse Count Method)

  • 손준원
    • 한국항공우주학회지
    • /
    • 제49권4호
    • /
    • pp.301-309
    • /
    • 2021
  • 펄스개수측정방법은 반작용휠의 속도를 측정하는 고전적인 방법이다. 본 연구에서는 펄스개수측정방법을 수식으로 표현하였다. 반작용휠의 회전을 속도가 아니라 샘플링 시간 동안의 회전각도로 모델링하였다. 제안된 모델의 유효성은 모델에서 얻어진 펄스개수 변화와 이동평균의 효과가 기존 연구결과와 동일함을 확인하는 방법으로 검증하였다. 이렇게 검증된 모델에 타코펄스 불균일성을 추가하고 펄스개수측정방법의 오차에 대해서 살펴보았다. 불균일성으로 인해서 증가하는 측정오차의 크기를 수식으로 표현하였으며, 측정오차를 상쇄하기 위해서 취해야 하는 이동평균의 개수 조건을 제시하였다.

픽셀 비선형성 모델을 기반으로 한 영상센서 불균일 특성 보정 (CCD Non-uniformity Correction Method based on Pixel Non-Linearity Model)

  • 김영선;공종필;허행팔;박종억;용상순
    • 항공우주기술
    • /
    • 제9권1호
    • /
    • pp.28-34
    • /
    • 2010
  • 균일한 광량의 빛이 카메라에 입력되었을 때 카메라 영상센서 각 픽셀은 이상적으로는 균일한 응답을 보여주어야 하지만 실제로는 그렇지 않다. 이러한 픽셀의 불균일 응답 특성은 영상품질에 직접적으로 영향을 미치지만, 고정된 형태의 잡음이므로 보정과정을 통해서 잡음을 제거할 수 있다. 영상센서 불균일 보정 방법은 특정 광량에서의 기준값만을 가지고 보정계수를 구하는 방법 등을 사용하곤 했지만, 센서의 비선형성으로 인하여 신호가 작은 경우, 혹은 반대로 아주 큰 경우에서는 보정 효과가 크지 않다. 따라서, 본 논문에서는 이러한 영상센서의 비선형 특성을 고려하여 픽셀 불균일 보정계수 계산하는 방법을 기술하고 자체 구현한 카메라와 별도의 시험셋업을 이용하여 불균일도 시험을 수행하여 알고리즘을 검증하였다. 시험결과는 비선형성 모델을 기반으로 한 보정 알고리즘을 적용했을 때, 모든 광량에서 가장 좋은 성능을 보여주었다.

A Non-uniform Correction Algorithm Based on Scene Nonlinear Filtering Residual Estimation

  • Hongfei Song;Kehang Zhang;Wen Tan;Fei Guo;Xinren Zhang;Wenxiao Cao
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.408-418
    • /
    • 2023
  • Due to the technological limitations of infrared thermography, infrared focal plane array (IFPA) imaging exhibits stripe non-uniformity, which is typically fixed pattern noise that changes over time and temperature on top of existing non-uniformities. This paper proposes a stripe non-uniformity correction algorithm based on scene-adaptive nonlinear filtering. The algorithm first uses a nonlinear filter to remove single-column non-uniformities and calculates the actual residual with respect to the original image. Then, the current residual is obtained by using the predicted residual from the previous frame and the actual residual. Finally, we adaptively calculate the gain and bias coefficients according to global motion parameters to reduce artifacts. Experimental results show that the proposed algorithm protects image edges to a certain extent, converges fast, has high quality, and effectively removes column stripes and non-uniform random noise compared to other adaptive correction algorithms.

Uniformity Improvement of SLS poly-Si TFT AMOLED

  • Park, Hye-Hyang;Lee, Ki-Yong;Kim, Kyoung-Bo;Kim, Hye-Dong;Chung, Ho-Kyoon
    • Journal of Information Display
    • /
    • 제6권3호
    • /
    • pp.22-25
    • /
    • 2005
  • In this study, we attempted to find the origin of brightness non-uniformity in SLS poly-Si TFT AMOLED. By developing a suitable SLS process with a compensation circuit, we successfully improved the non-uniformity from 40% to 1.7%. In addition, we were able to fabricate 2.2" AMOLED display using SLS poly-Si.

표면 검사를 위한 조도 균제도 기반 하이브리드 조명계 설계 (Hybrid Illumination System Design based on Illuminance Uniformity for Surface Inspection)

  • 조은덕;김경범
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.60-65
    • /
    • 2019
  • In this paper, the hybrid illumination system for effectively detecting surface defects in steel plate with lowcontrast, non-uniformity and featureless is designed based on illuminance uniformity. First of all, characteristics of steel plate defects were considered and typical inspection illumination system is implemented. Optimum illumination parameters for uniformly illuminating an inspection area in the typical illumination system are selected based on the illuminance uniformity and illuminance distribution measurement. The illuminance uniformity and illuminance distribution are measured using an illuminometer based on the arduino. Through illuminance distribution analysis of the typical illumination, an hybrid illumination is designed by fusing bi-directional illumination and coaxial illumination. The hybrid illumination showed higher uniformity ratio and illuminance distribution than the typical illuminations. The hybrid illumination system showed the ability to uniformly illuminate the entire inspection region of steel plate surface.