• Title/Summary/Keyword: Non-Radiation

Search Result 1,537, Processing Time 0.029 seconds

The Effect of Flame Radiation on NOx Emission Characteristics in Hydrogen Thrbulent Diffusion Flames (수소 난류확산화염에서 NOx 생성특성에 대한 화염열복사의 영향)

  • Kim, Seung-Han;Kim, Mun-Ki;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.2
    • /
    • pp.51-62
    • /
    • 2000
  • The relationship among the flame radiation, NOx emissions, residence time, and global strain rate are examined for turbulent non-premixed jet flames with wide variations in coaxial air conditions. Measurements of NOx emission, flame geometry and flame radiation were made to explain the NOx emission scaling based on global parameters such as flame residence time, global strain rate, and radiant fraction. The overall 1/2-power scaling is observed in coaxial air flames, irrespective of coaxial air conditions, but the degree of deviation from the 1/2-slope curve in each case differs from one another. From the comparison between the results of pure hydrogen flames and those of helium diluted hydrogen flames, it is observed that flame radiation plays a significant role in pure hydrogen flames with coaxial air and the deviation from 1/2-power scaling may be explained in two reasons: the difference in the flame radiation and the difference in jet similarity in coaxial air flames. From the radiation measurements, more detailed explanations on these deviations were suggested.

  • PDF

Preparation of Acrylic Acid-grafted Kenaf Fibers Using E-beam Irradiation and Evaluation of Permeability of Kenaf Fiber-cement Composites (전자선을 이용한 아크릴산 그라프트 케냐프 섬유의 제조 및 이를 이용한 케냐프 섬유보강 시멘트의 투수특성 평가)

  • Kim, Du Yeong;Jeun, Joon Pyo;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.53-57
    • /
    • 2014
  • The kenaf is quickly developing as a renewable resource. Kenaf can be grown under a wide range of weather conditions. Modification of kenaf fiber by graft polymerization provides a significant route to alter the chemical properties, including surface hydrophilicity or hydrophobicity. In this study, kenaf fiber surfaces were grafted with acrylic acid as a hydrophilic group using electron beam irradiation. The grafting rate increased with an increase in grafting time. The FT-IR results confirmed that acrylic acid was successfully grafted onto the kenaf fibers. The wettability of the kenaf fiber was increased, accompanied by acylic acid grafting on the fiber surface. According to the permeability test result, it was found that acrylic acid grafted kenaf fiber reinforced cement composite was more reduced than non-grafted kenaf fiber reinforced cement composite.

Constraining non-Gaussianity with Minkowski Functionals

  • Chingangbam, Pravabati;Park, Chang-Bom
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.42.2-42.2
    • /
    • 2010
  • The possibility of detection of deviation from Gaussian distribution of primordial perturbations in the Cosmic Microwave Background (CMB) Radiation is very important because it can shed light on how the perturbations were created in the very early universe. We study the effect of the primordal non-Gaussianity on topological observables called Minkowski Functionals, which are functions of the temperature fluctuation field, and show that they carry distinct signatures of different types of non-Gaussianities. Then, we constrain the non-Gaussianity parameters by comparing the theoretical predictions of the Minkowski Functionals with measurements from observational data from WMAP.

  • PDF

The Results of Radiation Therapy in Locally Advanced Non-Small Cell Lung Cancer (국소적으로 진행된 비소세포폐암의 방사선치료 성적)

  • Kim Mi Sook;Yoo Seoung Yul;Cho Chul Koo;Yoo Hyung Joon;Kim Jae Young;Shim Jae Won;Lee Choon Taek;Kang Yoon Koo;Kim Tae You
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.233-241
    • /
    • 1997
  • Purpose : This study was done to evaluate the survival rate and Prognostic factors of patients with inoperable non-small cell lung cancer(NSCLC) treated with radiation therapy. Materials and Methods A retrospective analysis was undertaken of 62 Patients who had inoperable NSCLC treated with radiation therapy from January 1991 through December 1993. According to AJCC slaging, stage IIIA was 14 patients and stage IIIB was 48 patients. Forty Gy to 70.2Gy to the primary tumor site was delivered with daily fractions of 1.8Gy or 2Gy, 5days per week. Thirty-seven patients received neoadjuvant chemotherapy. Results : Complete, partial and no response to radiation therapy were 3 patients, 34 Patients and 25 patients, respectively The median survival period of all patients was 11 month. One rear survival rate, 2 year survival rateand 5 rear survival rate for all patients were 45.0%, 14.3%, and 6.0% respectively The median survival period was 6.5 months in stage IIIA and 13 months in stage IIIB. One year survival rates were 28.6% in stage IIIA and 50.3% in stage IIIB In univariaite analysis, prognostic factors affecting survival were T-s1aging, AJCC staging, and response after radiation therapy (P<0.05) . Pretreatment peformance status affected survival but was not statistically significant (0.050.1). In multivariate analysis, Pathology and response to radiation therapy are independently significant prognostic factor. T stage was marginally significant (P=0.0809). During follow-up duration, distant metastasis developed in 20 patients-bone metastasis in 10 patients, brain metastasis in 3 patients, liver mentastasis in 3 patients, contralateral lung metastasis in 1 patients and multiple metastases in 3 patients. Conclusion : Conventional radiotherapy alone or combined chemoradiotherapy are unlikely to achieve long term survival in patients with NSCLC. Surgery after concurrent chemoradiotherapy is Ivied to improve the local control in our hospital

  • PDF

Differential non-linearity correction for successive approximation ADC

  • Yamada, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.847-850
    • /
    • 1987
  • In this paper a new method to correct the differential non-linearity(D NL) error for a successive approximation is proposed. The DNL of ADC is very important characteristic in the field of radiation pulse height analysis or measurement of probability density function. The results of computer simulations are shown to demonstrate the feasibility of the proposed correction method.

  • PDF

Radiation Therapy Results of the Non-Hodgkin's Lymphoma of the Sinonasal Cavity (비강 및 부비동 Non-Hodgkin's Lymphoma의 방사선 치료)

  • Kim Soo Kon;Park Kyung Ran;Lee Chang Gul;Suh Chang Ok;Kim Gwi Eon;Loh John J.K.;Hong Won Pyo;Kim Byung Soo;Ryu Samuel
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.97-104
    • /
    • 1987
  • From January 1970 through December 1984, 15 patients with sinonasal Non-Hodgkin's lymphoma combined to the head and neck were treated by external irradiation.13 patients were stage It and 2 were stage IIE by Ann Arbor Classification. However, when using TNM system, 7 were locally advanced T3, T4 lesions. All patients had follow up from 3.7 to 16 years with the median follow-up of 8.5 years. The overall actuarial 5-year survival rates were $25\%,\;28\%$ for IE and $0\%$ for IIE. Total tumor dose varied from 40 to 68 Gy. $100\%$ complete response with a total tumor dose of more than 55 Gy and $73\%$ complete response with less than 55Gy. When the disease was staged using the TNM (AJC) system, the five-year disease free survival for T1 and T2 patients was $50\%$ as compared with $14\%$ for T3 and T4. Failure rate by stage was $33\%(2/6)$ for T1 and T2, $86\%(6/7)$ for T3 and T4, and $100\%$(2/2) for IIE. The results suggest that 1. Higher CR could be obtained with a total tuner dose of more than 55 Gy. 2. Use of TNM staging system is as important as Ann arbor in management of sinonasal NHL. 3. The addition of combination chemotherapy should be considered for T3, T4 and IIE the sinonasal Non-Hodgkin's lymphoma although the disease is limited to head and neck.

  • PDF

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Evaluation of Quality Properties of Gamma-irradiated Freeze-dried Fruits (감마선 조사에 따른 동결건조과일의 품질 특성 평가)

  • Choi, Soo-Jeong;Yoon, Young-Min;Han, In-Jun;Kim, Jae-Kyung;Park, Jong-Heum;Lee, Ju-Woon;Lyu, Eun-Soon;Yook, Hong-Sun;Kim, Jae-Hun;Song, Beom-Seok
    • Journal of Radiation Industry
    • /
    • v.6 no.4
    • /
    • pp.299-304
    • /
    • 2012
  • The quality properties of freeze-dried apples, pears, strawberries and pineapples gamma-irradiated at 0, 1, 2, 3, 4, and 5 kGy were evaluated to develop germ-free products for immuno-compromised patients. The initial count of total aerobic bacteria in non-irradiated apples, pears, strawberries and pineapple was 2.5, 3.1, 2.6, and $3.2{\log}\;CFU{\cdot}g^{-1}$, respectively. Microorganisms were not observed in apples after 1 kGy, in pears and strawberries after 4 kGy, and in pineapples at 5 kGy within a detection limit of $10{\log}\;CFU{\cdot}g^{-1}$. In addition, the sterilization of each sample was confirmed at the same dose. The score for the overall acceptance of freeze-dried fruit irradiated at a sterilization dose was 5.5 for apples, 4.1 for pineapples, and 4.0 for the other fruits, whereas that of non-irradiated control sample was 5.6 for apples, 5.2 for pears, and 5.8 for strawberries and pineapples with a 7-point scale. As a result, gamma irradiation of 1 kGy for apples, 4 kGy for strawberries and pears, and 5 kGy for pineapples is sufficient to sterilize each freeze-dried fruit with acceptable sensory properties.