• Title/Summary/Keyword: Non-Locking

Search Result 63, Processing Time 0.022 seconds

Curved quadratic triangular degenerated-shell elements for geometric non-linear analysis (기하학적 비선형 해석을 위한 곡면 2차 삼각형 쉘 요소에 관한 연구)

  • Kim, Chang-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.46-53
    • /
    • 2005
  • Compare to the large number of curved quadrilateral degenerated-shell elements, there are only a very few curved triangular degenerated-shell elements. Based on the assumed natural strain sampling scheme previously developed for a quadratic degenerated-shell element for linear analysis, this paper devises geometric non-linear six-node degenerated-shell element. The element can be curved and is only equipped with the standard nodal d.o.f.'s. Careful consideration has been exercised to circumvent various locking phenomena that plague degenerated-shell element. Numerical examples are presented to illustrate efficiency.

Post-buckling and Elasto-plastic Analysis of Shell Structures using the Degenerated Shell Element (변형된 쉘요소를 이용한 판 및 쉘 구조의 후좌굴 및 탄.소성 유한요소해석)

  • 김문영;민병철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.17-27
    • /
    • 1995
  • For the post-buckling and elasto-plastic analysis of shell structures, the total Lagrangian formulation is presented based upon the degenerated shell element. Geometrically correct formulation is developed by updating the direction of normal vectors in the iteration process and evaluating the total Green-Lagrange stain corresponding U total displacements. In the calculation of the stiffness matrix, the element formulation takes into account the effect of finite rotation increments by retaining second order rotation terms in the incremental displacement field. The selective or reduced integration scheme using the heterosis element is applied in order to overcome both shear locking phenomena and the zero energy mode. The load/displacement incremental scheme is adopted for geometric non-linear F .E. analysis. Based on such methodology, the computer program is developed and numerical examples to demonstrate the accuracy and the effectiveness of the proposed shell element are presented and compared with references's results.

  • PDF

Static and Dynamic Analysis of Plate Structures using an Enhanced Finite Element (개선된 유한요소를 이8한 평판구조물의 정적 및 동적해석)

  • 김선훈;한인선;유승운;최창근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.169-176
    • /
    • 2002
  • This paper is concerned with development of an enhanced quadratic Mindlin plate bending element. The behavior of the proposed plate element is further improved by the coupled use of non-conforming displacement modes, the selectively reduced integration scheme, and the assumed shear strain fields. The improvement may be attributable to the fact that the merits of these improvement techniques are merged in the formation of the new element in a complementary manner. The proposed quadratic finite element passes the patch tests, does not show spurious mechanism, and does not produce shear locking phenomena even with distorted meshes. It is shown that the element produces reliable solutions through numerical tests for standard benchmark problems. It is also noted that the element is applicable to transient dynamic analysis of Mindlin plates.

  • PDF

An Experimental Study on Oil Pressure Distribution in the Piston-Cylinder Mechanism (피스톤-실린더 기구에서 오일압력 분포에 관한 실험적 연구)

  • Kim, Yeong-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.77-82
    • /
    • 2011
  • The piston-cylinder mechanism is widely adopted in the hydraulic machine components. In these cases, the hydrodynamic pressures are generated in the clearance gap between the piston and cylinder under lubrication action of the piston. Under the eccentric and tilted condition of the piston in the cylinder bore, the non-symmetric pressure distributions in the circumferential direction result in lateral forces. When the lateral forces act as increasing the eccentricity and tilting ratios, excessive wear can be result in cylinder and piston which are well known 'hydraulic locking' phenomena. In this paper, the hydrodynamic pressures generated in the clearance are measured using a stationary piston and moving cylinder apparatus. The experimental results showed that the hydrodynamic pressure distributions are highly affected by the speed and eccentricity of the cylinder and the oil viscosity.

A co-rotational 8-node assumed strain element for large displacement elasto-plastic analysis of plates and shells

  • Kim, K.D.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.2
    • /
    • pp.199-223
    • /
    • 2003
  • The formulation of a non-linear shear deformable shell element is presented for the solution of stability problems of stiffened plates and shells. The formulation of the geometrical stiffness presented here is exactly defined on the midsurface and is efficient for analyzing stability problems of thick plates and shells by incorporating bending moment and transverse shear resultant force. As a result of the explicit integration of the tangent stiffness matrix, this formulation is computationally very efficient in incremental nonlinear analysis. The element is free of both membrane and shear locking behaviour by using the assumed strain method such that the element performs very well in the thin shells. By using six degrees of freedom per node, the present element can model stiffened plate and shell structures. The formulation includes large displacement effects and elasto-plastic material behaviour. The material is assumed to be isotropic and elasto-plastic obeying Von Mises's yield condition and its associated flow rules. The results showed good agreement with references and computational efficiency.

Non-linear Analysis of Laminated Composite Plates with Multi-directional Stiffness Degradation (강성 저하된 적층복합판의 비선형 해석)

  • Han, Sung-Cheon;Park, Weon-Tae;Lee, Won-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2661-2669
    • /
    • 2010
  • In this study, a finite element formulation based first-order shear deformation theory is developed for non-linear behaviors of laminated composite plates containing matrix cracking. The multi-directional stiffness degradation is developed for adopting the stiffness variation induced from matrix cracking, which is proposed by Duan and Yao. The matrix cracking can be expressed in terms of the variation of material properties, such as Young's modulus, shear modulus and Possion ratio of plates, and sequently it is possible to predict the variation of the local stiffness. Using the assumed natural strain method, the present shell element generates neither membrane nor shear locking behavior. Numerical examples demonstrate that the present element behaves quite satisfactorily either for the linear or geometrical nonlinear analysis of laminated composite plates. The results of laminated composite plates with matrix cracking may be the benchmark test for the non-linear analysis of damaged laminated composite plates.

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Inventing Computer Desk for Education by Group (단체 교육용 컴퓨터 책상 개발)

  • Kang, Myung-Sun;Lim, Kwang-Soon
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.3
    • /
    • pp.193-202
    • /
    • 2008
  • In order to occupy educational furniture market that grows by the day and to meet demands for alternative product for the current market, this study took business features and productivity of Sinil Furniture Co into consideration, and developed computer desk for education by group, which is new among educational furniture. The scope of the study ranges from data research based on design process into creation of prototype. By improving the condition where, despite that electrically-powered computer desk for anti-theft system is high priced, it sees frequent malfunction, the study suggested low-priced, non- electrically-powered anti-theft system which has more solid structure. Furthermore, in order for the user to be more free and comfortable while studying on it, it differentiates from other products by locating PC main body to the back of the monitor and lowering it below the altitude of monitor to prevent it from interfering with studies. We've made the higher board of the desk in a soft curved-shape in order to lessen the stress from studying. And as space for the monitor's lower mount was decreased, we've put the lower mount below the higher board; so that lacking space can be recovered while functioning as anti-theft system. Moreover, we've covered the PC main body with steel cover so that it would add color and formal luxuriousness to the appearance of the desk. Considering ease of mobility and productivity, knock-down system was introduced.

  • PDF

A study on efficient operation of DC track circuit (DC 궤도회로의 효율적인 운용방법에 대한 연구)

  • Jang, Dongwan;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.70-75
    • /
    • 2014
  • A track circuit is a critical piece of equipment that allows the existence of the trains on the track to be detected. Train detection is very important for the signal safety equipment. It allows for the confirmation of a train's location, the locking of switch points, the coordination of safe distance between trains, and the advance notice of a train's arrival. Track circuits can be powered by AC or DC. The DC track circuits are usually used on non-electrified tracks. On these tracks, many signal errors can be caused by lightning or problems with the power source. These problems can also cause damages to the rectifiers which must be repaired or replaced, promptly. This issue is especially problematic in the summer because of the higher frequency of thunderstorms. Issues with track circuits also cause problems for other equipment, such as railroad crossings and switch points. This further disrupts the safe operation of trains. This study aims to enhance maintenance efficiency and improve safety by utilizing parallel operation and multiplexing of a DC track circuit as well as installing an external surge protector. The experimental results on the operation of the proposed method is also presented.

Surgical Treatment of Olecranon Fractures

  • Koh, Kyoung-Hwan;Oh, Hyoung-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Since the olecranon fractures are caused by relatively low-energy injuries, such as a fall from standing height, they are usually found without comminution. Less commonly they can be developed by high-energy injuries and have severe concomitant comminution or injuries to surrounding structures of the elbow. Because the fracture by nature is intra-articular with the exception of some avulsion-type fracture, a majority of olecranon fractures are usually indicated for surgical treatment. Even if there is minimal displacement, surgical treatment is recommended because there is a possibility of further displacement by the traction force of triceps tendon. The most common type of olecranon fracture is displaced, simple non-comminuted fracture (that is, Mayo type IIA fractures). Although tension band wiring was the most widespread treatment method for these fractures previously, there is some trends toward fixation using locking plates. Primary goal of the surgery is to restore a congruent joint and extensor mechanisms by accurate reduction and stable fixation so that range of motion exercises can be performed. The literature has shown that good clinical outcomes are achieved irrespective of surgical fixation technique. However, since the soft tissue envelope around the elbow is poor and the implants are located at the subcutaneous layer, implant irritation is still the most common complication associated with surgical treatment.