• Title/Summary/Keyword: Non-Invasive

Search Result 1,289, Processing Time 0.028 seconds

Remote Patient Monitoring Service through World-Wide Web (Web을 통한 원격 환자 모니터링 서비스)

  • Lee, H.S.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.188-191
    • /
    • 1997
  • In this paper, we present a real-time remote patient monitoring service through world-wide web, which allows the medical doctor to monitor his patients in remote sites using popular web browsers. The real-time service consists of two services: Patient Locator Service (PLS) and Vital Sign Monitoring Service (VSMS). The PLS provides the information of patients currently being monitored. The VSMS allows the user to observe a stream of vital sign data of a specific patient. The vital sign data include ECG, respiration, temperature, $SPO_2$, invasive blood pressure and non-invasive blood pressure.

  • PDF

A Real time Internet Game Played with a Brain-Computer Interfaced Animal (뇌-기계접속 된 동물과 사람사이의 실시간 인터넷게임)

  • Lee, H.J.;Kim, D.H.;Lang, Y.R.;Han, S.H.;Kim, Y.B.;Lee, G.S.;Lee, E.J.;Song, C.G.;Shin, H.C.
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.780-783
    • /
    • 2007
  • A Many studies have been made on the prediction of human voluntary movement intention in real-time based on invasive or non-invasive methods to help severely motor-disabled persons by offering some abilities of motor controls and communications. In the present study, we have developed an internet game driven by and/or linked to a brain-computer interface (BCI) system. Activities of two single neuronal units recorded from either hippocampus or prefrontal cortex of SD rats were used in real time to control two-dimensional movements of a robot, or a game object.

  • PDF

Urease를 이용한 위점막 시료에서 Helicobacter pylori의 신속한 진단법

  • Lee, Hak-Seong;No, Im-Hwan;Choe, Tae-Bu;Lee, Jong-Hwa
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.264-265
    • /
    • 2000
  • Helicobacter pylori(H. pylori) is the causative agent of chronic gastritis and the single most important factor in peptic ulcer disease, however, the pathogenetic mechanisms underlying H, pylori infection are not well understood. Futhermore, there is a strong association between H. pylori infection and gastric cancer. Various diagnostic methods for detecting H. pylori infection are available. These can be divided into invasive methods, requiring endoscopy, and non-invasive tests, mainly 13C-urea breath tests and serologic detection of antibodies. Rapid urease test is the most recommendable endoscopic test for the diagnosis of H. pylori infection, presently. CLO test kit is the represent of rapid urease test kits. The principles of CLO test kit is that hydrolysis of urea by urease Is detected by a dye indicators showing a color change. Our device is used same principle but we improved the reaction time is more faster and positive color change is more distinctive from the color of the negative specimen. So, this kit is more reliable because it response faster and accuracy.

  • PDF

LASER MICROWELDING FOR ELECTRICAL INTERCONNECTION IN BIOMEDICAL TECHNOLOGY (의료용 전기 접점부의 마이크로 레이저 용접)

  • ;B.K. Paul;J. Boogaard
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.45-48
    • /
    • 2003
  • Over the past few decades, there has been increasing research and commercial activity in invasive and non-invasive biomedical technology. One important challenge to developing these devices involves the increasing density of electrical interconnects. Resistance spot welding is limited in the density of interconnect based on either the size of welding head or the positional precision with which a weld can be made. Development of an automated laser microwelding system would permit the continued advancement of these important biomedical technologies. The objective of this work is to demonstrate the application of pseudo-pulse Nd:YAG laser technology as an alternative to resistance spot welding in performing electrical interconnection within biomedical products. To date, some experiments have been conducted by using a pseudo-pulse 1064 nm Nd:YAG laser, a successful weld of a 25 ${\mu}{\textrm}{m}$ diameter Pt/Ir wire to a 316 stainless steel shim can be made. Another application involves welding clips, which may be used for external interconnection, to electrodeposited nickel domes that make particular interconnections to specific insulated wires within a cable. These results show a great deal of promise for developing such a process.

  • PDF

CADICA: Diagnosis of Coronary Artery Disease Using the Imperialist Competitive Algorithm

  • Mahmoodabadi, Zahra;Abadeh, Mohammad Saniee
    • Journal of Computing Science and Engineering
    • /
    • v.8 no.2
    • /
    • pp.87-93
    • /
    • 2014
  • Coronary artery disease (CAD) is currently a prevalent disease from which many people suffer. Early detection and treatment could reduce the risk of heart attack. Currently, the golden standard for the diagnosis of CAD is angiography, which is an invasive procedure. In this article, we propose an algorithm that uses data mining techniques, a fuzzy expert system, and the imperialist competitive algorithm (ICA), to make CAD diagnosis by a non-invasive procedure. The ICA is used to adjust the fuzzy membership functions. The proposed method has been evaluated with the Cleveland and Hungarian datasets. The advantage of this method, compared with others, is the interpretability. The accuracy of the proposed method is 94.92% by 11 rules, and the average length of 4. To compare the colonial competitive algorithm with other metaheuristic algorithms, the proposed method has been implemented with the particle swarm optimization (PSO) algorithm. The results indicate that the colonial competition algorithm is more efficient than the PSO algorithm.

Aortic rupture (대동맥 파열)

  • 정철하
    • Journal of Chest Surgery
    • /
    • v.26 no.11
    • /
    • pp.838-844
    • /
    • 1993
  • Rupture of aortic is for the most part a terminal disorder and requires prompt and aggressive treatment. Most of the patients who develop this condition outside the hospital die before appropriate therapy can be instituted. Thus prompt treatment, sometimes innovative, resulted in a highly significant survival rate. We experionced 21 aortic rupture due to mycotic aneurysm and another 3 due to chest trauma. Operation was done in 11 cases, and mortality was 3 of 11 cases. In another 10 cases, operation was not performed and all of them were expired. We confirmed diagnosis using only non invasive technic as ultrasonogram and computed tomography and invasive technic like aniography was absolutely avoided. Preoperative management was aimed to lower blood pressure for the purpose of preventing srcondary bleeding, and operantions erer porformed promptly if possible.

  • PDF

A Case of Pneumothorax after Phrenic Nerve Block with Guidance of a Nerve Stimulator

  • Beyaz, Serbulent Gokhan;Tufek, Adnan;Tokgoz, Orhan;Karaman, Haktan
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.105-107
    • /
    • 2011
  • Hiccups have more than 100 etiologies. The most common etiology has gastrointestinal origins, related mainly to gastric distention and gastroesophageal reflux disease. Intractable hiccups are rare but may present as a severe symptom of various diseases. Hiccups are mostly treated with non-invasive or pharmacological therapies. If these therapies fail, invasive methods should be used. Here, we present a patient on whom we performed a blockage of the phrenic nerve with the guidance of a nerve stimulator. The patient also had pneumothorax as a complication. Three hours after intervention, a tube thoracostomy was performed. One week later, the patient was cured and discharged from the hospital. In conclusion, a stimulator provides the benefit of localizing the phrenic nerve, which leads to diaphragmatic contractions. Patients with thin necks have more risk of pneumothorax during phrenic nerve location.

Remote Patient Monitoring through the Internet (인터넷을 통한 원격환자 모니터링)

  • 박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.377-383
    • /
    • 2001
  • In this paper, we present an intensive patient monitoring service through the Internet, which enables medical doctors to watch their patients in a remote site, to monitor their vital signs and to give them some advices for first-aid treatment. The service consists of three service objects: Monitoring Information Service(MIS), Vital Sign Monitoring Service(VSMS) and Multimedia Consulting (MCS). Through the MIS, medical doctors can get information about the patients currently under monitoring, including their names, ages, genders, symptoms, current main complaints and current locations. The VSMS enables medical doctors to monitor in real-time patients' vital signs such as electrocardiogram (ECG), respiration, temperature, blood oxygen saturation (SpO$_{2}$), invasive blood pressure (IBP), and non-invasive blood pressure (NIBP). It also generates alarms when the patients are likely to be in a critical situation. The MCS provides a real-time multimedia desktop conferencing facility for watching patients and instructing attendants to administer some first-aid treatment. We carried out some experiments according to two different scenarios. The intensive patient monitoring service was functioning well in a 100Base-T Ethernet LAN environment.

  • PDF

Robotic Surgery for Lung Cancer

  • Ambrogi, Marcello C.;Fanucchi, Olivia;Melfi, Franco;Mussi, Alfredo
    • Journal of Chest Surgery
    • /
    • v.47 no.3
    • /
    • pp.201-210
    • /
    • 2014
  • During the last decade the role of minimally invasive surgery has been increased, especially with the introduction of the robotic system in the surgical field. The most important advantages of robotic system are represented by the wristed instrumentation and the depth perception, which can overcome the limitation of traditional thoracoscopy. However, some data still exist in literature with regard to robotic lobectomy. The majority of papers are focused on its safety and feasibility, but further studies with long follow-ups are necessary in order to assess the oncologic outcomes. We reviewed the literature on robotic lobectomy, with the main aim to better define the role of robotic system in the clinical practice.

Spontaneous Intracranial Vertebral Artery Dissection in a 2-Year-Old Child Diagnosed with High-Resolution MRI: a Case Report

  • Heo, Subin;Han, Miran;Kim, Sung Hwan;Choi, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.259-263
    • /
    • 2019
  • Although many imaging modalities can play some roles in the diagnosis of vertebral artery dissection (VAD), digital subtraction angiography (DSA) remains the gold standard method, with the highest detection rate and ability to assist in planning for endovascular treatment. However, this tool is often avoided in children because its invasive nature and it exposes them to radiation. High resolution magnetic resonance imaging (HR-MRI) have been suggested to be a reliable and non-invasive alternative, but it has never been discussed in children in whom vertebral artery dissection is a rare condition. In this report, we evaluate a case of a 2-year-old child who initially presented with cerebellar symptoms, and was early diagnosed with vertebral artery dissection using HR- MRI and was successfully treated.