• Title/Summary/Keyword: Noise standards level

Search Result 109, Processing Time 0.024 seconds

A study on Traffic Noise control by the Environmental facilities around Roadway (도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구)

  • Sul Jeung Min;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.2 s.5
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

A brief review on the standards of regulations and compensation in the environmental noise and vibration disputes resolution (환경소음.진동 피해 분쟁 조정을 위한 기준설정에 관한 소고)

  • Lee, Soo-Gab;Kim, Jae-Hwan;Kim, Kyu-Tae;Hong, Ji-Young;Eun, Hee-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.876-878
    • /
    • 2008
  • The standards of acceptable limit and compensation is one of the most important things in environmental noise and vibration disputes resolution. In this paper, review on the present acceptable limit level and compensation standard in National Environmental Dispute Resolution Commission is introduced. Discordance of standards between in the regulation law and in the dispute resolution commission and it's improvement are discussed. Abnormal reasoning for compensation standards is pointed out from a author's private view.

  • PDF

A Low-noise Double Relaxation Oscillation SQUID Magnetometer for Measuring Magnetoencephalogram

  • 강찬석;이용호;권혁찬;김진목;윤병운
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.151-158
    • /
    • 2002
  • We developed a useful SQUID magnetometer for biomagnetic applications, magnetoencepha-logram(MEG) and magnetocardiogram(MCG), etc. The SQUIDs are based on Double Relaxation Oscillation SQUID(DROS). DROS consists of two SQUIDs(signal SQUID and reference SQUID) in series, and a relaxation circuit of an inductor and a resistor. Specially we used single reference junction instead of the reference SQUID. The SQUIDs are based on hysteretic $Nb/AlO_{x}$Nb junctions, fabricated by using a simple four level process. Because DROS magnetometer has large flux-to-voltage transfer coefficient, we can use simple flux-locked loop electronics fur SQUID operation. When the DROS magnetometer was operated inside a magnetically shielded room, its average magnetic field noise was about 3 (equation omitted) at 100 Hz. This noise level is low enough to measure biomagnetic fields. In this paper, we describe noise characteristics of DROS magnetometer, depending on the operation condition . .

  • PDF

A Study on Standards of Transformer Noise Level for Outdoor Substation (옥외 변전소 변압기의 소음레벨 기준에 대한 연구)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Kwak, Ju-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2213-2219
    • /
    • 2008
  • Customer complaints on noise from the power transformer have been increased because of their concerns on environment. In order to solve fundamental noise problem of the transformer, KEPCO and domestic transformer manufacturers are developing 55 dBA class low noise transformers. To check accordance of the noise abatement law, we study relation between transformer noise level and substation border noise level. We present 'noise level of the substation border' under operating conditions and transformer noise level change. We also present an appropriate noise level of the transformer that satisfy the noise abatement law for outdoor substations.

Field Measurement of Airborne Sound Insulation for Noise Reduction about Community Facilities in an Apartment Complex (공동주택 단지 내 주민공동시설의 소음 방지를 위한 공기전달음 차단 성능 현장 조사)

  • Seong, Yo-Han;Kim, Jin-Sik;Kim, Hye-Won;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.249-250
    • /
    • 2023
  • The objective of this study is to evaluate the airborne sound insulation performance between housing units and community facilities during the construction phase. Community facilities adjacent to housing units can lead to noise problems, hence it is necessary to minimize noise transmission during the design phase. However, flanking noise transmitted through gaps of structures, windows, pipes, and other openings may result in substandard sound insulation performance falling below the design standards. Therefore, It is crucial to measure airborne sound insulation in the field during the construction phase. The measurement was conducted using the survey method for the field measurement of the airborne sound insulation in accordance with KS F ISO 10052:2021. Although the noise standards caused by community facilities in apartment complexes are not specified in current laws and regulations, desired noise level was set based on international guidelines for indoor noise. First, the level of noise generated in community facilities was estimated, and then the sound insulation performance was evaluated to determine whether the desired noise level was achieved.

  • PDF

A Study on the Improvement Plan of Construction Noise Monitoring (공사장 소음모니터링 개선방안에 관한 연구)

  • Park, Young-Min;Kim, Kyoung-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1056-1065
    • /
    • 2013
  • Noise generated from Construction site has been raised most civil complaints to 64.4 % among the environmental pollution in 2011. Therefore, local government recommends and prescribes that construction sites over a certain scale install sound level meter for noise monitoring. For example, Seoul has implemented a 24 hour noise monitoring system, with real time communication, to the large construction sites more than 10,000 $m^2$ from the end of August 2012. But it is difficult to use noise measurement data for the construction noise assessment, since the installation standards and technical specifications for construction noise monitoring system are not presented. In this paper, we proposed noise monitoring system improvement plan including technical specifications and installation standards using the investigating results of the problems of current noise monitoring system and the foreign cases.

Assessment of Can Factory working noise and its reduction (산업현장의 소음.진동 원인분석 및 저감방안 연구)

  • Chun, Hyung-Jun;Ko, Sun-Hee;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.212-216
    • /
    • 2006
  • The purpose of this study is to obtain an effective enclosing method for noise reduction of press machine operating in a manufacturing company located in Korea. Noise level of the machine is about $90{\sim}105dB$ which is higher than legal standards by industrial safety and health law. This study has predicted the level of noise reduction according to a step by step prevention plan by considering the characteristics of the cause of noise, the permitted limit of noise levels, problems and economical efficiency attendant upon the noise prevention measures. The predicted level of noise at the plant in accordance with the first step is $71.5{\sim}89.5dB(A)$, and can satisfy the permitted limit of noise in a time period of the day. Based on these results, enclosing method adequate for the selected plant's noise characteristics were suggested.

  • PDF

The Standardization of Sound Quality evaluation method for the vehicle interior noise (차량 실내 소음에 대한 음질 평가 방법의 표준화)

  • Park, Sang-Gil;Kim, Ho-San;Oh, Jae-Eung;Bae, Chul-Yong;Lee, Bong-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.303-310
    • /
    • 2007
  • The vehicle noise is classified into interior and radiated exterior noise. And it influences on consumer‘s vehicle decision and traffic noise environment very much. In case of the vehicle exterior noise, it is related with traffic noise and in case of the interior noise, it is related with driver’s and passenger‘s sensitivity quality. Because these influenced on drivers and traffic environment, so standards are restricted by the laws and regulated for the measurement. But, the existence standards measuring the only sound pressure level are limit to reflect consumer’s sensitive aspects. Therefore in this study, the recent standards and laws were searched about domestic and abroad papers and the testing mode for the sound quality (SQ) evaluation was constructed about the vehicle interior noise. Finally, we aimed at the standard establishment to evaluate the vehicle interior SQ using statistics method.

  • PDF

The Standardization of Sound Quality Evaluation Method for the Vehicle Interior Noise (차량 실내 소음에 대한 음질 평가 방법의 표준화)

  • Park, Sang-Gil;Lee, Hae-Jin;Bae, Chul-Yong;Lee, Bong-Hyun;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1230-1237
    • /
    • 2007
  • The vehicle noise is classified into interior and radiated exterior noise. And it influences on consumer's vehicle decision and traffic noise environment very much. In case of the vehicle exterior noise, it is related with traffic noise and in case of the interior noise, it is related with driver's and passenger's sensitivity quality. Because these influenced on drivers and traffic environment, so standards are restricted by the laws and regulated for the measurement. But, the existence standards measuring the only sound pressure level are limit to reflect consumer's sensitive aspects. Therefore in this study, the recent standards and laws were searched about domestic and abroad papers and the testing mode for the sound quality(SQ) evaluation was constructed about the vehicle interior noise. Finally, we aimed at the standard establishment to evaluate the vehicle interior SQ using statistics method.

ENVIRONMENTAL NOISE POLICIES AND NOISE CONTROL PRACTICE IN CHINA

  • Tian, Jing
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.25-32
    • /
    • 2005
  • In China, environmental noise policies are composed of correlated laws adopted by the Standing Committee of the National People's Congress and promulgated by the President of the country, regulations promulgated by the State Council and/or local government, standards issued by the Standardization Administration Committee (SAC) under the State Council. The laws mainly include the 'Environmental Protection Law' and the 'Law on Prevention and Control of Pollution From Environmental Noise' Regulations are often applied to a special noise pollution phenomenon of wide influence. They are generally only effective in a given area and/or a specific period. Tens of correlated standards specify the noise level limits of different functional zones of land use and of different equipment, machines, devices, appliances etc., and the measurement methods. In this presentation, a brief introduction to these policies and their operations is given and discussed. The conclusion is that the policies supply an effective legislative basis for environmental noise prevention and control in China, but still a lot of work should be conducted and completed to strive for a quiet society.

  • PDF