• Title/Summary/Keyword: Noise measurement methods

Search Result 434, Processing Time 0.027 seconds

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

An Ultra-precision Electronic Clinometer for Measurement of Small Inclination Angles

  • Tan, Siew-Leng;Kataoka, Satoshi;Ishikawa, Tatsuya;Ito, So;Shimizu, Yuuki;Chen, Yuanliu;Gao, Wei;Nakagawa, Satoshi
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.539-546
    • /
    • 2014
  • This paper describes an ultra-precision electronic clinometer, which is based on the capacitive-based fluid type, for detection of small inclination angles. The main parts of the clinometer low-noise electronics are two capacitance measurement circuits for converting the capacitances of the capacitors of the clinometer into voltages, and a differential amplifier for obtaining the difference of the capacitances, which is proportional to the input inclination angle. A 16 bit analog to digital (AD) converter is also embedded into the same circuit board, whose output is sent to a PC via RS-232C, for achieving a small noise level down to tens of ${\mu}v$. A compensation method, which is referred to as the delay time method for shortening the stabilization time of the sensor was also discussed. Experimental results have shown the possibility of achieving a measurement resolution of $0.0001^{\circ}$ as well as the quick measurement with the delay time method.

Analysis on Indoor Noise Condition of Cafeteria in University Campus (대학교 학생식당의 소음저감을 위한 실내소음 실태분석)

  • Choi, Yoon-Jung;Lee, Seon-A;Kim, Hye-Kyeong
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.05a
    • /
    • pp.85-88
    • /
    • 2007
  • This research is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to investigate the present condition of physical level, type, and source of indoor noise by comparison with a restaurant near campus. Methods were field survey with measurement on equivalent and instant noise level and observation on noise type, and questionnaire survey to 60 students users. Surveys were carried out in the 8th and the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$(average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$(average 71.2) dB(A), but noise levels of the restaurant were $61.6{\sim}70.4$(average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$(average 64.9) dB(A). 2) The users's responses on major noise type were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'taking noise' in cafeteria, but 'taking noise' and 'background music' in restaurant. 3) It was found that the differences of indoor noise condition between with 2 subjects were caused by finishing materials, kitchen division type, and furniture type.

  • PDF

Aero-acoustic Performance Analysis Method of Regenerative Blower (재생형 송풍기의 공력음향학적 성능 해석 방법)

  • Lee, Chan;Kil, Hyun Gwon;Kim, Gang Chun;Kim, Jun Gon;Ma, Jae Hyun;Chung, Kyung Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.2
    • /
    • pp.15-20
    • /
    • 2013
  • An aero-acoustic performance analysis method of regenerative blower is developed as one of the FANDAS codes. The aerodynamic performance of regenerative blower is predicted by using momentum exchange theory coupled with pressure loss and leakage flow models. Based on the performance prediction results, the noise level and spectrum of regenerative blower are predicted by discrete frequency and broadband noise models. The combination of the performance and the noise prediction methods gives aero-acoustic performance map and noise spectrum analysis results, which are well-agreed with the actual measurement results within a few percent relative error.

Highway traffic noise modeling and estimation based on vehicles volume and speed

  • Rassafi, Amir Abbas;Ghassempour, Jafar
    • Advances in environmental research
    • /
    • v.4 no.4
    • /
    • pp.211-218
    • /
    • 2015
  • Traffic noise estimation models are useful in evaluation of the noise pollution in current circumstances. They are helpful tools for design and planning new roads and highways. Measurement of average traffic noise level is possible when traffic speed and volume are known. The objective of this study was to devise a model for prediction of highway traffic noise levels based on current traffic variables in Iran. The design of this model was to take the impact of traffic congestion into consideration and to be field tested. This study is a library research augmented by field study conducted on Saeedi Highway located south west of Tehran. The period for the field study lasted 5 days from 7-12 February, 2013. This study examined liner and non-liner methods in formulation of its model. Liner method without a fixed coefficient was the best fit for the intended model. The proposed model can serve as a decision making tool to estimate the impact of key influential factors on sound pressure levels in urban areas in Iran.

Comparison of ERG Denoising Performance according to Mother Function of Wavelet Transforms (웨이브렛 변환의 모함수에 따른 ERG의 잡음제거 성능 비교)

  • Seo, Jung-Ick;Park, Eun-Kyoo;Jang, Jun-Young
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.756-761
    • /
    • 2016
  • Purpose. Noise occurs at measuring Electoretinogram(ERG) signals as the other bio-signal measurement. It is compared the denoising performance according to the mother function of wavelet transforms. Methods. The ERG signal that generated power supply noise and white noise was used as a sampling signal. The noise of ERG signal was filtered by using haar, db7, bior mother function. The filtering performance of each mother functions was compared using Fourier transform spectrum and SNR(signal to noise ratio). Results. In the haar functioin, the result of the Fourier transform spectrum was that the power supply noise is removed and the white noise performance is not good. The SNR was 27.0404. In the db7 function, the results of Fourier transform spectrum was that the power supply noise is removed and the white noise performance is good. The SNR was 35.1729. In the db7 function, the results of Fourier transform spectrum was that the power supply noise is removed and the white noise performance is the bset. The SNR was 35.4445. Conclusions. The db7, bior function was good results in power supply noise and white noise filtered. The bior function is suitable for filtering noise of the ERG signal.

A Noise Investigation of Transverse Rumble Strip at Toll Plaza of Highway (고속도로 영업소 광장의 횡방향 럼블스트립으로 발생되는 소음 조사)

  • An, Deok-Soon;Suh, Young-Chan;Kwon, Soo-Ahn;Lee, JaeJun;Eom, Byeong-Sik
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.31-36
    • /
    • 2013
  • PURPOSES: This study is to investigate a generated traffic noise when vehicle pass over a transverse rumble strip at toll plaza of highway. METHODS: To investigate traffic noise at toll plaza of highway, Pass-by method which is the most common used for measuring traffic noise was adopted and the traffic noise at toll plaza was measured for 10 min per hour for 11hours(13:00~24:00). RESULTS: The measured traffic noise by pass-by method was changed as function of the transverse rumble strip configuration. Generally, the maximum difference among three noise measurement sections was 7 dB(A). It might be related with traffic speed. Also, the measured traffic noise was strongly generated from a passenger car which was 2 axle. It means that the most of traffic noise on the road is generated at tire/pavement interface of the passenger car. CONCLUSIONS: The traffic noise was strongly related with vehicle speed and transverse rumble strip configuration on the road. For driver safety, the transverse rumble strip is definitely necessary. However, the complaints from residents near highway was increased by traffic noise from transverse rumble strip. Therefore, To satisfy both safety and reduction of traffic noise, the development of configuration of transverse rumble strip is necessary in the further study.

Measurement methods of the acoustic characteristics of absorption materials (흡음재의 특성평가를 위한 측정방법에 대하여)

  • 김연수;서상준;조문재;황철호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.65-69
    • /
    • 1990
  • 건축재로서 사용되고 있는 흡음재료의 기본적인 특성을 제시해 주는 요소중 의 하나는 흡음계수이다. 본 논문에서는 흡음계수 측정의 새로운 연구결과를 제시하기 보다는 유리면(glass wool)을 대상으로 흡음계수 측정시 현재 주로 이용되고 있는 측정방법중 수직입사와 random 입사 방법의 이론적인 배경과 측정에 따른 문제점등을 간단하게 소개하고자 한다.

  • PDF

Ricean Bias Correction in Linear Polarization Observation

  • Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.267-271
    • /
    • 2011
  • I developed an enhanced correction method for Ricean bias which occurs in linear polarization measurement. Two known methods for Ricean bias correction are reviewed. In low signal-to-noise area, the method based on the mode of the equation gives better representation of the fractional polarization. But a caution should be given that the accurate estimation of noise level, i.e. ${\sigma}$ of the polarized flux, is important. The maximum likelihood method is better choice for high signal-to-noise area. I suggest a hybrid method which uses the mode of the equation at the low signal-to-noise area and takes the maximum likelihood method at the high signal-to-noise area. A modified correction coefficient for the mode solution is proposed. The impact on the depolarization measure analysis is discussed.

A Study on the reduction effect of noise and vibraton using auger-drilled piling (매입 말뚝공법의 항타공해 저감효과)

  • 박찬국;박용부
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1995.10a
    • /
    • pp.1031-1040
    • /
    • 1995
  • Recently, a more strict regulation has become effective on ground vibration and noise induced by construction activities. Consequently the demand for the most widely used method of installing precast piles, i.e. driven piles, is declining. At the same time the demand for low noise and low vibration piling method increased sharply. Currently there are several different low noise and low vibration methods of installing precast piles, mostly preboring method. However, the actual level of ground vibration and noise of these method of construction has not yet been clearly understood. In this paper, through field measurement, suggestion has been made to meet the requirements of the revised regulation.

  • PDF