• Title/Summary/Keyword: Noise level evaluation

Search Result 439, Processing Time 0.029 seconds

Research on evaluation for the noise of HDD (HDD의 소음도 평가에 대한 연구)

  • 최성준;문원규;강성우;황태연
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.543-548
    • /
    • 2002
  • Nowadays since the customers of HDD's are interested in their noise levels in addition to their primary performances such as their average access time, capacity, HDD manufacturers make efforts on reducing the noise. The works to reduce noise are usually based on the measurable physical quantities such as SPL or acoustic intensity level. However, since the HDD noise is Judged by human beings, the basis of noise reduction should be human sensations. In this paper, the noise levels of various HDD's are evaluated by the human jury test to find a relationship between the physical quantities used for noise control and the human sensations of noise. Discrepancies are found in the judgments by the human beings and by the physical quantities. The loudness level, a psychoacoustic variable, is used to solve the discrepancy.

  • PDF

An analysis of railway noise from comparison and evaluation between A-weighted SPL and sound quality indices (A-weighted 음압레벨과 음질 지수의 평가 및 비교를 통한 철도소음의 해석)

  • Kim, Dae-Sung;Wang, Se-Myung;Shin, Min-Cheol;Cho, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1459-1464
    • /
    • 2006
  • In the previous studies on railway noise analysis, the main purpose of noise analysis is concerned with the reduction of A-weighted sound pressure level in order to satisfy noise regulations. However, more important facts on noise reduction are the subjective feelings of the human being on noise because people might be annoyed from the noise caused by train. In this paper, railway noise from different type of train are compared using the calculation of sound quality metrics with using strength related method that is calculation of A-weighted sound pressure level.

  • PDF

Noise Automatic Gain Control to Stabilize Radar Performance (레이다 성능 안정화를 위한 잡음 AGC)

  • Kim, Kwan-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.132-137
    • /
    • 2007
  • The dynamic range of the radar which uses digital signal processors is limited by ADC(Analog-to-Digital Converter). That parameter and ADC loss depend on the noise level of radar receiver. In order to stabilize the performance of radar systems, it is necessary to maintain the noise level constantly. This paper presents the noise AGC(Automatic Gain Control) concept that can keep the noise level constantly and proves that the concept is acceptable through the hardware test and evaluation.

Sound Quality Evaluation and Development of Sound Quality Index for High-Speed Train Interior (고속철도의 실내 음질평가와 음질인덱스 개발)

  • Park, Buhm;Choi, Sung-Hoon;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.827-827
    • /
    • 2009
  • Complaints against high-speed train interior noise have been increasing as a number of high-speed train passenger grows bigger. It is very difficult to analyze characteristics of high-speed train interior noise using sound pressure level only. It is requested to consider how the public response change for each high-speed train interior noise. This study presents evaluation of the sound quality for interior noise of KTX-II using Zwicker parameters. Characteristic of loudness and sharpness is different between noise samples depending on operation condition. The noise sample that recorded when the high-speed train passed through tunnel section is more louder and sharper.

  • PDF

Study on the annoyance response of subway station noise using jury evaluation test (청감실험을 통한 도시철도 승강장 소음의 성가심 반응에 대한 연구)

  • Kim, Dong-Jun;Kim, Deuk-Sung;Son, Jin-Hee;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.670-677
    • /
    • 2009
  • The purpose of this study is to reveal the quantitative dose-response relationship between the noise emitted in the platform of subway station and the public response. The noise measured in the platform of subway station was used for a jury test. In order to find the factors which influence annoyance response due to the platform noise, jurors were examined for the difference of the annoying response, interrelation of sound quality parameter and annoyance response. The platform noise level was 77.2$\sim$83.9 dBA and the most of passengers at the platform were highly annoyed. And screen door contributes to annoyance reduction of platform noise. The results from analyzing sound quality parameters shows that loudness and annoyance response have a high correlation coefficient.

  • PDF

Optimization for Component Noise Validation Test by Evaluation of Noise Control Factors for Suspension (현가장치 소음 발생인자 평가를 통한 부품소음 검증시험 최적화)

  • Son, Myungkoon;Lee, Taeyong;Lee, Sangbok;Lee, Seul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.3
    • /
    • pp.344-349
    • /
    • 2017
  • Suspension noise from under a passenger car is one of the important factors that impact the perceptual quality for drivers. However, it is difficult to validate this by component level testing in the early stage of development, because suspension noise caused by interaction of the related parts has been found at saleable vehicles late during development or at the manufacturing stage, when many customers have already filed for claims. This study proposed a validation testing under research by the DFSS process that enables reproduction of vehicle level noise by component level testing using a shock absorber with the related parts, such as urethane bumper and top mount. This study also developed a compromised test matrix while analyzing the noise factors through experimental design and analysis of variance to determine what factors can affect noise. Based on this study, we expect that the vehicle level and customer claim can be validated during initial development timing by a more reliable component noise validation test.

An Experimental Study on the Noise Evaluation of H.D. TV sets by Psycho-acoustic Experiments (청감실험을 통한 고화질 TV set 소음평가에 관한 실험적 연구)

  • Lee, Ju-Yeob;Lee, Tai-Gang;Kim, Hye-Jin;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1014-1023
    • /
    • 2006
  • The purpose of this study is to propose the proper vocabularies for evaluating H.D TV set fan noise. To achieve this goal, psycho-acoustic experiments were carried out with TV set fan noise modulated at specific frequency band. Finally, a correlation analysis between vocabularies, and a factor analysis of psycho-acoustical responses were conducted. As a result of this study, followings are suggested. Analyzing the psycho-acoustical response corresponding to the various sound level, the higher the sound levels, the higher the response values were. It is estimated that the sound level determined psycho-acoustical responses. On the degree of response to fan noise, the initial level of negative feeling is located on $35{\sim}40$ dB(A). The factor of evaluating H.D. TV set fan noise has induced three the appropriate korean adjectives; Irritate, Monotonous, stuffy and dryness. The result of this study may be used to evaluate the acoustic threshold level for indoor noise or a basis for specifying the desired acoustic environment of dwellings.

Jury Evaluation Test for Annoyance Response of KTX(Korea Train Express) and Ordinary Train Noise (고속철도와 일반철도소음의 성가심 반응에 대한 청감실험 비교 연구)

  • Chun, Hyung-Joon;Kim, Deuk-Sung;Ko, Joon-Hee;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.335-344
    • /
    • 2008
  • In recent years, public complaints against railroad noise by KTX and Ordinary train have been rising. Regulation of railways noise uses same standard without distinguishing the type of railroad cars. According to the type of railroad cars, the frequency characteristics of emitting noise is different. Therefore it is requested to know how the public response vary to each types of railroad cars. The noise annoyance from three types of trains(KTX, electric train, diesel train) was analyzed by jury evaluation test for assessing the effect of frequency characteristics. The numerical results by a semantic differential method showed that annoyance response to three type of trains depended on the frequency characteristics. As a result, this study proposed that the KTX could have a bonus level of maximum 2.9 dB(A) compared to ordinary train.

Evaluation on Attenuation for Sound-absorbing Measures of Loud Noisy Work-site using Auralizational Technique (가청화를 이용한 고소음 작업장의 흡음대책 평가)

  • Yun, Jae-Hyun;Kim, Jae-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.8
    • /
    • pp.742-752
    • /
    • 2010
  • In case of the working machine that using in the loud-noisy workplace, as it generates the loud-noise, it is influencing a physical, mental bad effect to those workers. Accordingly, though the noise countermeasure for the loud-noisy workplace is acutely requiring, until now, those methods that wearing the soundproof-protection tool, or restriction the working hours, and minimize the noise exposure volume, were mainly used. However, such noise countermeasures occur many problem points. On such point of view, using the acoustic simulation technique, let the workers to choose the workplace where suffering many damages due to the noise of working machine, and after grasp the physical property of working machine and indoor acoustic characteristic, this Study has attempted to grasp the reduction degree of noise level at before-improvement?after-improvement, through the sound-absorption measure. Passing through such preceding step, using auralizational technique based on the noise of working machine of before-improvement after-improvement, and by conduct psycho-acoustics evaluation, this study intended to investigate the change degree of subject reaction. As the result of evaluation, it is considering that the noise-reduction countermeasure method for the loud-noisy workplace could be much effective, through the sound-absorption measure.

Subjective Evaluation of Stage Acoustics with the alteration of the sound pressure level of reverberation. (잔향음압의 변화에 대한 무대음향의 주관적 평가)

  • Kim, Young-Sun;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.742-742
    • /
    • 2003
  • This study is about the effect of the sound pressure level of reverberation on stage acoustics. There are several electro-acoustics systems to enhance the room acoustics of concert hails but not many studies on the stage acoustics for the musicians who plays on the stages. To investigate the effect of reverberation on stage acoustics, the reverberation time of a test room has been controlled through a 4 channel speaker system, and the preferred reverberation level has been selected by performing musicians. As a result, the sound pressure level of reverberation seems to affect the perception of stage acoustics which motivates musicians' performances.

  • PDF