• Title/Summary/Keyword: Noise Through Floor

Search Result 123, Processing Time 0.048 seconds

A study on the capability of inverse A weighting through the auditory perception test (청감실험을 통한 역A특성 평가방법의 타당성 검토)

  • 이성찬;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.586-591
    • /
    • 2002
  • Recently, the research and discussion to set up the evaluation standard for nor impact noises in multistory residential buildings has been vividly carried out In Korea. Therefore, the correlation between the methods and auditory responses was investigated through this research to investigate the applicability of the L index evaluation method and the reverse A characteristics evaluation method that are listed in JIS A 1419 since Japanese circumstance are similar to Korean after evaluating the duality of Korean multistory residential buildings. As a result, it was found that the correlation between the value resulted from L index evaluation and the value from reverse A characteristics evaluation is high. In addition, it was also revealed that human responses to each Impacter was similar. Consequently, it is considered th:31 the tendency about the two methods would be similar.

  • PDF

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

A Case Study on Inside Noise Reduction of Agricultural Tractor Cab(I) -Analysis of Sound and Sound Intensity Levels- (농용 트랙터의 안전캡 내부 소음 감소에 관한 연구( I ) -소음과 음향 강도 수준 분석-)

  • 유동호;김경욱;김재열
    • Journal of Biosystems Engineering
    • /
    • v.20 no.2
    • /
    • pp.117-126
    • /
    • 1995
  • High level of tractor noise may reduce operator's work performance and cause a hearing problem. This study was carried out to investigate the cab noise of a selected agricultural tractor. The noise was measured and analyzed in terms of sound and sound intensity levels. Form the results it was known that a structure-born noise was induced from the feet-rest and rear floor panel of the cab. The air-borne noise caused mainly by the engine was transmitted into the operator's position through the small openings of cab structures in the operator's lower front area.

  • PDF

A Consideration on the Establishment of Standard level for Floor Impact Sound Insulation (바닥충격음 차단성능 기준설정 고찰)

  • 송민정;기노갑;장길수;김흥식;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.226-229
    • /
    • 2001
  • Recently the impact sound insulation performance is regarded as one of the most import factors in determining the quality of housing environment. In order to reduce the impact sound level transmitted through the floors and structures, establishing the standard level of impact sound insulation performance is needed. In this consideration, The effecting facts for the standard insulation level is reviewed.

  • PDF

Response Of Steel Frame Structures With Added Elastic Dampers (탄성 댐퍼가 추가된 대형철골 구조물의 응답특성)

  • 배춘희;조철환;양경현;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.808-812
    • /
    • 2002
  • The feasibility of using elastic dampers to mitigate earthquake-induced structural response is studied in this paper. The properties of elastic dampers are briefly described. A procedure for evaulating the elastic damping effect when added to a structure is proposed in which the damping effect of elastic dampers is incorporated into modal damping ratios through an energy approach. Computer simulation of the damped response of a multi-storey steel frame structure shows significant reduction in floor displacement levels.

  • PDF

A Study on the Sanitary Piping System Plan When an Aged Public Housing is Remodeled (노후 공동주택의 위생설비 리모델링 계획방안에 관한 연구)

  • Han, Soo-Gon;Lee, Sang-Youp;Lee, Seung-Yeon;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.569-574
    • /
    • 2008
  • Recently, the domestic remodeling market is increased in scale. This study is to develop the sanitary piping system which improves quality of life and facility performance when the aged public housing is remodeled. Above all, we found out three standard floor plans in bathrooms of the public housing. And then, the plan and section types of the sanitary piping system were developed for the on-floor piping, a construction cost of each section types was estimated to review the economical fact. Also, the field mock-up test was performed in the type of the pipe shaft with on-floor pit. In result, the developed sanitary piping system was available for the remodeling public housing without a great facility cost. Additionally, the sanitary pipe was replaced easily through the shaft and on-floor fit. And a noise was reduced to a lower unit when the water flowed down.

  • PDF

Survey and Evaluation for Exterior Noise of a High Rise Apartment in Seoul (서울시 초고층 아파트의 외부소음 측정과 평가)

  • Lee, Seon-Dong;Park, Yu-Ra;Lee, Sang-Woo;Yoo, Ho-Chun
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.95-101
    • /
    • 2004
  • As a part of acoustical design, it is often necessary to quantify aspects of an existing environment and to predict the result of adding an acoustical treatment. The most common sources of exterior noise, also termed as environmental noise,(or community noise) are traffic noise, air craft noise, industrial noise, etc. Transportation(air, road, and rail)noise is the dominant and most common source of noise exposure in residential neighborhoods, and the annoyance is its most consequential effect. The road traffic noise becomes aggravated due to the rapid increase of vehicles. It has a great effect on the dwelling environment. Therefore we investigate the characteristics and sources of the road traffic noise through grasping the status of the road traffic noise. In the present study, preceding studies investigated the noise level of urban areas in Seoul were reviewed and the noise level of urban areas in Seoul was measured at first, fifth, tenth, and nineteenth floor for two days of weekdays and two days of weekend.

Design and Implementation of an Indoor Particulate Matter and Noise Monitoring System (실내 미세먼지 및 소음 모니터링 시스템 설계 및 구현)

  • Cho, Hyuntae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • As the COVID-19 pandemic situation worsens, the time spent indoors increases, and the exposure to indoor environmental pollution such as indoor air pollution and noise also increases, causing problems such as deterioration of human health, stress, and discord between neighbors. This paper designs and implements a system that measures and monitors indoor air quality and noise, which are representative evaluation criteria of the indoor environment. The system proposed in this paper consists of a particulate matter measurement subsystem that measures and corrects the concentration of particulate matters to monitor indoor air quality, and a noise measurement subsystem that detects changes in sound and converts it to a sound pressure level. The concentration of indoor particulate matters is measured using a laser-based light scattering method, and an error caused by temperature and humidity is compensated in this paper. For indoor noise measurement, the voltage measured through a microphone is basically measured, Fourier transform is performed to classify it by frequency, and then A-weighting is performed to correct loudness equality. Then, the RMS value is obtained, high-frequency noise is removed by performing time-weighting, and then SPL is obtained. Finally, the equivalent noise level for 1 minute and 5 minutes are calculated to show the indoor noise level. In order to classify noise into direct impact sound and air transmission noise, a piezo vibration sensors is mounted to determine the presence or absence of direct impact transmitted through the wall. For performance evaluation, the error of particulate matter measurement is analyzed through TSI's AM510 instrument. and compare the noise error with CEM's noise measurement system.

Improvement of Sound Transmission Class in the Front Door of Apartment (공동주택의 현관문 차음성능 개선을 위한 연구)

  • Lee, Byung-Kwon;Bae, Sang-Hwan;Hong, Cheon-Hwa;Song, Man-Soo;Jung, Mun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.93-96
    • /
    • 2004
  • In the case of the front door of the apartment, which functions as an entrance, the study about noise has been less active than corridor type plane in the past, since stair room type plane was generalized. Hence, this study shows the survey about residents' thoughts of noise transmission through the front door, and after researching sound insulation of the present apartments, we figured out what the problem is. Moreover, we did an efficiency test as developing the front door, which increases sound insulation. As a result, it turned out that residents think that the noise transmission through the front door is as serious as floor impact noise, and also, the efficiency of the front door is as poor as STC 22-30. Therefore, in the developed front door, we should improve the efficiency to the level of STCSS. It will be a good way preparing for a demand of residents.

  • PDF

A Study on Valuation of Acoustic Performance about Dome-typed Gymnastics Training Floor utilizing Auralization (가청화를 이용한 돔형 체조연습장의 음향 성능평가에 관한 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Jung, Eun-Jung;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.132-136
    • /
    • 2007
  • In case of indoor gymnastics training floor, in view of its characteristics, since it is simultaneously required the related smooth communication between the coach and the player, also the acoustic performance regarding to the Clearness of Music, besides the sport activity, the consideration about the acoustic character has entered the stage as an indispensable element. On such viewpoint, on the object of the recently built dome-typed gymnastics training floor, after making the optimized acoustic design with the remodeling through acoustic simulation, by means of measurement and valuation on human's psychological(sensual) degree utilizing Auralization that enables to experience the virtual sound field at the stage of design, this thesis has attempted to survey of the acoustic satisfaction degree and its reaction about the gymnastics training floor. As the result of investigation about the research on the space of object, it could be known that the valuation regarding to the acoustic performance of 'After-Improvement' was distinctly more refined than that of 'Before-Improvement'. It is now considering that such result of the study can be utilized as the useful data which enables to improve the retrenchment effect of the construction cost as well as the acoustic capability, by means of the prediction control on the acoustic problem from the stage of design, for the occasion when the similar indoor sport gymnasium is planning to build for the near future.

  • PDF