• Title/Summary/Keyword: Noise Standard

검색결과 1,472건 처리시간 0.03초

소음지도에 나타난 환경기준 초과소음지역에 대한 소음저감대책 수립에 관한 연구 (A Study on the Counterplan of Noise Reduction for the Noise Excess Area of Environment Standard Appeared in Noise Map)

  • 임재석;이병찬;고준희;박수진;장서일;송귀석;김재선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1048-1052
    • /
    • 2007
  • Using road traffic noise, noise map for CheongJu city was drawn. Noise level is estimated and many regions of the city are classified noise excess area compared with environment standard value. Counterplan for the noise excess areas is presented in this study. Noise reduction methods are given in many ways, for example soundproofing walls, low noise pavement, low noise arrangement of buildings and low noise windows.

  • PDF

급수압에 따른 대변기 설비소음에 관한 연구 (A study on the Plumbing system noise of closet bowl by water supply pressure)

  • 김항;최은석;고광필;기노갑;이태강;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.11-16
    • /
    • 2006
  • It appraises that use an indoor noise standard, a NC value which is a noise appraisal, a dB(A) value, a N value in foreign country because it doesn't yet ready an appraisal standard in domestic. Also, It appraises that the supply and drainage noise which could change water supply pressure, $4kg/cm^2,\;3kg/cm^2,\;2kg/cm^2,\;1.5kg/cm^2,\;1kg/cm^2$, bring about a noise and inquires how does noise level indicates according to each instruments. In case of a water supply pressure standard, $3kg/cm^2$, a C-605is $3{\sim}5dB(A)$ lower than another instruments in directly overhead stories. It appears that all of them is similar to level in directly under level except c-407(2)Analyzed the NC value, c-605is the lowest level, NC-50, of a water supply pressure, $4.0kg/cm^2$, c-407 is the highest level, NC-55.(3) In case of N value, which is one of water supply methods in Japan, it is the lowest level, N-55, of a water supply pressure, $4.0kg/cm^2$ same as NC value and C-407is the highest level, N-60.(4) In case of water supply that is likely to noise level, It appears 6dB(A) level gap each instruments, and C-605 is the lowest level, 63.9dB(A).

  • PDF

대학주변 원룸형 다가구주택의 소음측정평가 (Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus)

  • 최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

철도소음과 그 영향 (Railroad Noise and its Impact)

  • 강대준
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.827-836
    • /
    • 1997
  • To suggest the standard of railroad noise and its measures and grasp its status 15 open sites of the Jungang. Taeback and Youngdong line in which the background noise level is very low and the railroad is at grade and 7 urban sites of the Kyungboo and Honam line were selected and the sound level which 373 trains passing through the former and 271 trains passing through the latter emitted was investigated. The community response of railroad noise was surveyed for apartment near wayside. Noise reduction of wall for apartment at the wayside was investigated. The prediction of electric train subway noise is derived for the environment impact assessment.

  • PDF

선형모형과 표준편차에 기반한 잡음영상에 효과적인 에지 검출 방법 (An effective edge detection method for noise images based on linear model and standard deviation)

  • 박영호
    • 응용통계연구
    • /
    • 제33권6호
    • /
    • pp.813-821
    • /
    • 2020
  • 최근 다양한 분야에서 사진, 동영상 등과 같이 비정형 데이터를 이용한 연구가 활발하게 진행되고 있다. 이 중에서도 영상을 활용하는 연구들은 영상에 포함된 정보를 사용하기 위하여 많은 영상처리 기법들을 사용하고 있다. 에지 검출은 영상에서 정보를 추출하기 위해 많은 영상처리 응용 프로그램에서 사용되는 기본 도구이다. 그러나 잡음이 포함된 영상은 에지와 잡음이 모두 고주파 성분을 가지고 있기 때문에 에지 검출을 수행하는 것은 매우 어렵다. 본 논문은 잡음이 감소된 에지를 추출하는 방법으로 선형모형과 표준편차를 이용하였다. 화소 블록에 포함된 화소들의 표준편차와 선형모형의 적합으로 얻어진 잔차에 대한 표준편차의 차이로 에지를 검출하였다. 에지 검출의 결과는 영상처리 분야에서 대표적으로 사용되는 소벨 에지 검출기의 결과와 비교하였다. 잡음이 포함되지 않은 영상은 소벨 에지 검출 결과와 제안한 에지 검출의 결과가 유사하게 나타나고, 제안한 방법이 다양한 수준의 잡음이 추가된 영상에서 잡음에 의한 에지가 적게 나타나는 것을 확인하였다.

급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구 (An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom)

  • 이태강;고광필;최은석;김항;김선우
    • 한국소음진동공학회논문집
    • /
    • 제17권3호
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

방음벽 설치에 따른 철도소음의 변화에 관한 연구 (A Study on the Variation of Rail Noise by Noise Barrier)

  • 윤해동;조원희;양만우;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1344-1349
    • /
    • 2000
  • With rapidly industrial development, a railway has become of a main traffic means. But, the railway noise has caused much annoyance for the residents living nearby railway tracks. Therefore, in our country, for established of Quite dwelling environment, execute regulation standard of railway noise from January 1, 2000. Efficiency soundproofing measures, however, are very difficult because of the lack of basic data and insufficiency of the existing research. In this point, this study attempts to survey the characteristics of attenuation and propagation of railway noise in by existence of noise barrier. And this study intends to get the basic data for establishment of a standard about railway noise.

  • PDF

풍력발전기 소음 성능 실증 (Noise Performance Test and Evaluation of a Wind Turbing Generator)

  • 김석현;김태형;박무열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.241-245
    • /
    • 2005
  • This study introduces the wind turbine (W/T) noise evaluation procedure required in the international standard (IEC 61400-11) and monitoring system for the evaluation. Noise emission characteristics of a 750kW W/T generator is investigated. Test and evaluation are performed on J48 W/T model which is under operation in Daekwanryung Wind Test Site. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level and tonality of the W/T are estimated under the wind speeds required by the international standard.

  • PDF

국제선 운영변화에 따른 김포국제공항의 항공기 소음 분석 (Analysis of Aircraft Noise at Gimpo International Airport according to Changes in International Flight Operations)

  • 조현수;박재식
    • 한국항공운항학회지
    • /
    • 제31권4호
    • /
    • pp.116-125
    • /
    • 2023
  • Gimpo International Airport is a strategically utilized airport based on government policy, but there are many residents living around the airport, so it is very sensitive to changes in airport operation. In the past, similar noise results were obtained for aircraft noise at Gimpo International Airport despite changes in aircraft types and an increase in the number of aircraft operating, and recently ICAO proposed a low-noise aircraft noise standard (Ch.14). Since the new standard has a noise reduction effect of up to 15dB compared to existing aircraft noise, ICAO and Europe EASA predict that future aircraft noise will be reduced if the latest technologies such as low-noise aircraft are applied. Therefore, this study establishes the aircraft operation performance and measured noise of Gimpo International Airport in 2022 as a baseline scenario, noise changes using various scenarios of introduction of low-noise aircraft, operation of mid-to-long-distance routes, and changes in future air traffic demand were analyzed using simulation.