• Title/Summary/Keyword: Noise Reduction Countermeasure

Search Result 46, Processing Time 0.025 seconds

Noise Source Identification and Countermeasure for the Noise of LPG Injector (LPC 인젝터의 소음원 규명 및 소음저감 대책)

  • Kim, Won-Jin;Park, Chong-Hyun;Kim, Sung-Dae;Lee, Byung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.144-151
    • /
    • 2002
  • This work focuses on finding out the noise source and the method of reducing the noise level of LPG(liquefied petroleum gas) fuel injector. The noise of LPG injector in operating condition is due to the impact between valve and valve seat. This study shows that if the revolution of engine is increased, the noise of LPG injector will be more serious but it is not nearly affected by the increment of fuel pressure. The source and transmission paths of noise are identified through the analysis of noise generation mechanism and noise spectrum. The sound absorbing material is tested to verify its efficiency of sound absorption thor the LPG injector. The effect of noise reduction of absorbing material is remarkable when the engine speed is high. Consequently two methods of reducing the noise level are suggested from the identified results. The one is to equip the absorbing material on the outer side of injector and the other is to coat with a soft material or equip a soft ring on the surface of impact.

A Study on the Noise Reduction in Railway Vehicles using Bone Conduction Device : Railway noise analysis and Understanding Acoustic Characteristics of Bone Conduction Devices

  • Park, Hyung Woo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.8 no.4
    • /
    • pp.48-53
    • /
    • 2016
  • Noise and vibration pollution is emerging to people in high speed trains. And it is difficult to realization of eco-friendly railway system at noise problem. The railway internal noise is 73dB on average and over 80dB in the loudest section. In order to reduce noise, there are passive methods that are far from noise sources and theother active noise reducion method. In this paper, we propose a method of reduce noise by measure and estimate the noise condition of train environment using Bone-Conduction device. We use an anti-phase waveform for canceling of noise characteristic. With this new system, the noise from surrounding environments can be reduced.

Vibration Reducing Method for High Pressure Feedwater Heater Drain Piping System (고압급수가열기 배수계통 배관계 고진동 해소방안 연구)

  • Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Sang-Bok;Hong, Soon-Bup;Shin, Yong-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1290-1295
    • /
    • 2006
  • The 120 meters high pressure feedwater heater drain piping in nuclear power plant had been suffered by excessive vibration from the beginning of power generation. As time goes by, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of high pressure feedwater heater drain piping and the countermeasure for abnormal vibration were investigated. Among the several vibration reduction methods, the piping layout changed by making the smooth pipeline was applied to the high Pressure feedwater heater drain piping in nuclear Power plant. Applying the countermeasure, the vibration level was found to reduce over 54 percents and was satisfied under the allowable velocity at the full-power operation condition.

  • PDF

A study on Providing the Estimation of the road traffic noise in the apartment according to physical characteristics (물리적 특성에 따른 공동주택에서 도로교통소음의 추정모델에 관한 연구)

  • Chang, Jung-Hee;Lee, Kang-Hee;Kim, Gon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.89-93
    • /
    • 2003
  • The ambient noise in modem society is the factor to give people serious influence. Noise barriers installation is mostly used in the apartment estate to protect countermeasure about the road traffic ambient noise. The purpose of this study is to suggest reference data fur design of traffic noise reduction in apartment estate. It finds out how the traffic noise is measured about a noise barriers and physical characteristics. The 57dB was measured from the noise barriers in a 2m point. An ambient noise's of the part to belong noise attenuation is big at the sound arresting area of the noise barriers as the distance far.

  • PDF

A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing (대변기 세정시 발생하는 배수소음의 특성변화에 관한 연구)

  • Soul, Soo-Hwan;Jung, Chul-Woon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.789-796
    • /
    • 2007
  • It has been noted, in case of the apartments in collective form, the drainage noise from cleaning of toilet causes many problems in the basement and adjacent rooms, mainly hampering the pleasant housing environment. The problems are increasingly raised by civil complaints with the public offices. Therefore, if the drainage noise generates when wash out of toilet bowl is grasped how the characteristics change according to the sorts of drainpipe, it is considered that the establishment of an effective sound insulation countermeasure could be possible when a civil petition against the drainage noise of apartment house is submitted hereafter. On such viewpoint, this study measured and analyzed the characteristics of drainage noise per the type of drainage pipe, according to KS A ISO $1996-1{\sim}3$, with the horizontal branch pipe and riser pipes in the drainage noise experiment chamber which has the characteristics of the anechoic room. In the result, the pipe type with excellent noise reduction function. The result of this study is considered to become available as fundamental data, to take actions on reduction of drainage noise of the ceiling piping method.

Vibration Characteristics and its Countermeasure of Orifice Pipe for Reduction Gear Lubrication of Azimuth Thruster (아지무스 추진기의 감속 기어 윤활용 오리피스 파이프 진동특성과 방진대책)

  • Eam, Gitak;Barro, Ronald D.;Lee, Donchool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.555-558
    • /
    • 2013
  • A type of electric propulsion employed by specialized purpose vessels or offshore is the azimuth thruster. Azimuth thruster application had been increasing recently and resulted to excellent vessel maneuverability. However, this system is very complex and some of its major component being exposed under the seawater level presents difficulty in sealing design. For Polar class icebreaker operating in extreme sea condition, this requires a high level of reliability and safety. In this study, the characteristics of lubricating orifice pipe structural vibration installed at the lower reduction gear were investigated and analyzed through beam analysis theory and comparison of experiments. Propeller excitation and the resonant modes of vibration causing excessive vibration and suitable countermeasures to prevent damage due to vibration fatigue on the pipe are presented.

  • PDF

Study on Reduction of Excessive Noise and Vibration of Aft Part of High Speed Ro-Ro Passenger Ship (고속 여객선 선미부 과대 진동/소음 감소를 위한 연구)

  • Shin, Yunkil
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.196-202
    • /
    • 2019
  • In this study, the excessive noise and vibration phenomena of a high-speed Ro/Ro passenger ship were analyzed, and a countermeasure was taken based on them. This ship was granted a comfort class notation by the classification society, which was COMFORT-VIBRATION-II and COMFORT-NOISE-CREW-II. However, unfortunately, excessive noise and vibration in the aft part of the ship were delivered from the twin shaft propellers, and therefore the Class Requirement was not satisfied before delivery. In order to obtain the class notation, all of the concerned parties came to an agreement to reduce the noise and vibration level during operation after delivery because a seasonal ferry service was already scheduled and the cabin was fully booked. The root cause of the massive amount of noise and vibration was mainly the propeller-induced excitation pulse and beating that occurred from the mismatch of the rotating speeds of the two shaft lines. A 1st order vibrating force and beating phenomena existed in the propeller. Thus, a reduction of the excitation force, elimination of the beating phenomena, and decrease of the noise level at the aft area cabins and public spaces were required. In addition, structural reinforcements were conducted using pillars and additional girders at the aft part of the decks.

A Study on the Noise Diagnosis and Suppression of the Temperature Sensor in the LCD Plant (LCD공장 내부의 온도센서 노이즈진단 및 억제에 관한 연구)

  • Kim, Kyung-Chul;Choi, Hyoung-Bum;Hwang, Young-Rok;Kim, Yong-Kwan;You, Chang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.35-41
    • /
    • 2012
  • As automation equipment and electronic device progresses, the importance of power quality is more increasing. This paper represents the analysis and suppression about the causes of trouble by the inverter's ON/OFF noise in plant in order to prevent damage resulting in a secondary damage to conduct precise diagnosis and effective noise reduction. The countermeasure as a reduced carrier frequency and the LC resonant filter had been applied and confirmed the effective results to solve the trouble of noise.

Analysis of Noise Source for Mold Transformer (몰드변압기의 소음 원인 분석)

  • Choi, W.H.;Kim, W.C.
    • Journal of Power System Engineering
    • /
    • v.4 no.4
    • /
    • pp.59-64
    • /
    • 2000
  • Especially, demands for the noise reduction of mold transformer has been becoming an common issue because it has been used mainly at the residence area such as building and ship. So, this paper investigates the noise source and countermeasure of mold transformer radiated high noise abnormally. The result of impact hammering test for core of transformer ascertains the core resonance by harmonics of line frequency and high noise can be reduced to avoid core resonance by changing torque strength of tie rod. Magnetic field analysis is performed to identify the reason that noise of V-phase is higher than U and W-phase in the normal condition. It is the cause that flux density and magnetic force of V-phase is higher than the other phase respectively.

  • PDF

A Study on the Prediction of Building Equipment Noise Generates at Machine Room (기계실에서 발생하는 설비소음의 예측에 관한 연구)

  • You, Hee-Jong;Jung, Eun-Jung;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.476-484
    • /
    • 2007
  • Recently, in accordance with the buildings are becoming to large-sizes, high-stories, the large scaled facilities and equipments in machine room are quite demanding, and the generated noise volume according to this situation is on increasing. Since such noise is becoming to the object of a serious civil appeal, it is the real situation that a reduction countermeasure against the machine room equipment noise is keenly necessitated. On such viewpoint, this study has recorded, measured the noises which were generated from each individual as same as the whole equipped machines and tools, on the object of the dormitory machine rooms of the 3 colleges that haying mutually different peculiarities, then after grasp-ing their characters and acoustic powers, this research has verified its prediction possibility and the authenticity by comparison the estimated numerical value with the actually measured numerical value through the acoustic simulation. After grasping the prediction possibility in such way, by utilization of the sound absorption material in the machinery room, from the stage of design, the soundproof measures for the noise reduction at machine room could be regulated effectively, and it is also considered that such data would be utilized as the fundamental material for an establishment of the measure for sound insulation.