A Case Study on Noise Effect Assessment and Countermeasure by Emergency Generators installed in an Exterior and interior Architecture (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Hong, Chang-Wan;Kim, Han-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.88-93
    • /
    • 2012
  • Recently data centers are being established or expanded according to IT industry development. A data center must be to install emergency generator. In case of the data center located the densely populated urban area, the operating noise of an emergency generator can be the cause of complains. In this case, in order to establish an effective and economical measure and quantitative and thorough review is needed by noise & vibration specialists. To achieve this, in this study, it is suggested noise reduction measure using noise measurement data and 3D noise analysis method.

  • PDF

A Case Study on Noise Impact Assessments and Countermeasures for Emergency Generators of the Data Center Building (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Kim, Han-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.932-939
    • /
    • 2012
  • Recently, data centers are being established because IT and telecommunication industries are growing. The data centers have to install emergency generators to prevent unexpected shutdown of the electrical power supply. When the data centers are located in the densely populated urban area, the operating noise of the emergency generators can be a cause of people's complaints. In this case, it is necessary to establish effective countermeasure by noise & vibration specialists. To achieve this, noise reduction measure using noise measurement data and 3D noise analysis method have been employed in this study.

A Study on the Evaluation for Reduction Effect of Hydraulic Turbine Dynamo Noise after Establishment of Soundproof Measure (방음대책 수립 후 수차발전기 소음의 저감효과 평가에 관한 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.133-137
    • /
    • 2007
  • As the waterpower generation plant, the subject of this Study, is a facility that produces plenty of electricity corresponds to $196{\sim}240GWh$ annually, and in its generation process it creates a loud noise when the turbine related to the hydraulic turbine dynamo revolves, and since such loud noise must be transmitted to the dynamo room and amplified, it is effecting a lot of influences to the adjacent office and space. In such viewpoint, this Research, based on the soundproof measure presented at the preceding research, has attempted to evaluate about the effect of noise-reduction countermeasure against the hydraulic turbine dynamo using Auralizational Technique through Psycho-Acoustics Experiment. It deems that such result could be applied hereafter as the useful material when setting up a soundproof countermeasure for the hydraulic turbine dynamo room in dam.

  • PDF

Vibration Reduction Method for Discharge Line of Moisture Separator Reheater (습분분리재열기 배수관 진동저감방안)

  • 이준신;손석만;김태룡
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

Evaluation on Attenuation for Sound-absorbing Measures of Loud Noisy Work-site using Auralizational Technique (가청화를 이용한 고소음 작업장의 흡음대책 평가)

  • Yun, Jae-Hyun;Kim, Jae-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.8
    • /
    • pp.742-752
    • /
    • 2010
  • In case of the working machine that using in the loud-noisy workplace, as it generates the loud-noise, it is influencing a physical, mental bad effect to those workers. Accordingly, though the noise countermeasure for the loud-noisy workplace is acutely requiring, until now, those methods that wearing the soundproof-protection tool, or restriction the working hours, and minimize the noise exposure volume, were mainly used. However, such noise countermeasures occur many problem points. On such point of view, using the acoustic simulation technique, let the workers to choose the workplace where suffering many damages due to the noise of working machine, and after grasp the physical property of working machine and indoor acoustic characteristic, this Study has attempted to grasp the reduction degree of noise level at before-improvement?after-improvement, through the sound-absorption measure. Passing through such preceding step, using auralizational technique based on the noise of working machine of before-improvement after-improvement, and by conduct psycho-acoustics evaluation, this study intended to investigate the change degree of subject reaction. As the result of evaluation, it is considering that the noise-reduction countermeasure method for the loud-noisy workplace could be much effective, through the sound-absorption measure.

A Study of Industrial Robot for the Noise and the Vibration Reduction (산업용 로봇의 소음/진동 저감 연구)

  • Lee, Kwang-Yal;Chung, Jin-Tai;Jung, Du-Han;Yim, Heung-Soon;Kim, Young-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.146-151
    • /
    • 2002
  • The object of this study is an examination of source of robot noise and reduction of the noise and the vibration for an industrial robot system. As the first step in our study, the noise and the vibration from the robot are measured by microphones and by accelerometers and the source of the noise and the vibration are proved to be from the gear, shaft, and housing from the experiments. The occurrence of the noise may be classified according into kinds, Finally base on the result of the experiments, we consider a countermeasure for reducing the noise and the vibration of robot system by the parametric study.

  • PDF

A Study of Industrial Robot for the Noise and the Vibration Reduction (산업용 로봇의 소음/진동 저감 연구)

  • Lee, Kwangyal;Jintai Chung;Duhan Jung;Yim, Hueng-Soon;Kim, Young-Hwin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.321.1-321
    • /
    • 2002
  • The object of this study is an examination of source of robot noise and reduction of the noise and the vibration for an industrial robot system. As the frist step in our study, the noise and the vibration from the robot are measured by microphones and by accelerometers and the source of the noise and the vibration are proved to be from the gear, shaft, and housing from the experiments. The occurrence of the noise may be classified according into kinds, Finally base on the result of the experiments, we consider a countermeasure fur reducing the noise and the vibration of robot system by the parametric study.

  • PDF

Noise Reduction of Reciprocating Type Air Compressors (왕복동식 공기압축기의 소음저감에 관한 공학적 대책 연구)

  • Lee, Kwang-Gil;Park, Jae-Suk
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.12-16
    • /
    • 2006
  • This paper deals with the noise evaluation and noise reduction of a reciprocating air-compressor. The reciprocating air-compressor is widely used in the small and medium sized industrial firms, many employees exposed and irritated by their noise in the workplace. Thus, appropriate noise control actions should be taken to prevent hearing loss due to the its noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known to be motor, belts, suction valves, discharge valves, moving parts, and flow-induced noise caused by edges or discontinuities along the flow path including expansions, contractions, junctions and bends. As a result, the main noise sources of the air-compressor are categorized by the suction and discharge noise, valve noise, and compressed air tank noise. Based on the investigations, mufflers are designed to reduce both the suction and discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, a noise reduction up to 10dB(A) could be achieved for the air-compressor.

A Study on Noise Reduction of Railway Noise by Noise Barrier (방음 터널 설치에 따른 소음 저감 효과 연구)

  • Kim, Da rae;Kim, Tae min;Kim, Jeung Tae;Son, Jeung gon;Park, Gwang hyeon;Ryu, Raeeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.125-130
    • /
    • 2014
  • High speed railroad car and high-rise apartment with development of railway technology cause different problems of noise contrary to the previous generation. It is the most efficient noise reduction countermeasure but we studied that is the way on noise propagation with sound proof wall or sound proof tunnel around railroad. But if it were railroad on bridge, additional cost which is more expensive than installing one on the ground is needed. So sound insulation material considering reducing weight of recent soundproof facilities must be selected. It is in this study that predicted and analyzed acoustical and structural effect for noise reduction by installing soundproof tunnel. If it were departmentalized into additional study, could be able to expect noise reduction effect of sound proof tunnel establishment on the bridge.

  • PDF

Analysis and Countermeasure for Shock-proof Performance of Laptop Computers (노트북 컴퓨터의 충격성능 분석 및 대책)

  • 임경화;윤영한;안채헌;김진규;이승은
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.490-495
    • /
    • 2001
  • This paper deals with an analysis and countermeasure for improving the shock performance of laptop computers. The shock analysis is carried out by using the commercial program of LS-DYNA3D. Also the analysis is verified by the measurements from modal tests and shock tests. The available countermeasures are investigated theoretically and experimentally to find the effective methods of reducing the shock acceleration on hard disk driver during one side fall test. The hard disk drive is the most sensitive part in a laptop computer. This research shows the effects of the spring constant of rubber pad, the reinforcement of mechanical parts and the location of a hard disk driver, on the shock reduction.

  • PDF