• 제목/요약/키워드: Noise Dosimeter

검색결과 22건 처리시간 0.019초

소음노출량측정기의 Set Up 방법간의 시간가중평균값(TWA)의 차이 (Difference of Time Weighted Averages in Different Setting Ups for Noise Dosimeter)

  • 양흥석;이광묵;원정일
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.193-199
    • /
    • 1995
  • This study was designed to investigate the difference of time weighted average(TWA) of noise levels and noise doses by the different operating parameter settings such as exchange rate, threshold level and criterion level for noise dosimeter in the field measurements of noise at industrial working environments. The time weighted averages of noise level and noise doses for noise working environments were determined by noise dosimeter on 80 workers employed at 20 industrial establishments of 8 industries. The results obtained were as follows: 1. The mean time weighted average(TWA) of the noise working environments by the operating parameter settings showed 93.4 dB(A) in 3 dB of exchange rate, 80 dB of threshold level and 90dB of criterion level 92.0 dB(A) in 3 dB-exchange rate, 90 dB-threshold level and 90 dB-criterion level, in 90.8 dB(A) in 5 dB of exchange rate, 80 dB of threshold level and 90 dB of criterion level, and 86.7 dB(A) in 5 dB of exchange rate, 90 dB of threshold level and 90dB of criterion level. 2. ln group of noise level less than 90 dB(A), mean TWAs of 80 dB of threshold level were significantly higher than that of 90 dB of threshold level in 3 dB and 5 dB of exchange rate. 3. The case exceeded threshold limit value of noise was 49(61.3 %) in 3dB, 80dB and 90 dB setting, 44(55.0 %) in 3 dB, 90 dB, 90 dB setting, 33(41.3 %) in 5 dB, 80dB, 90 dB setting and 26(32.5%) in 5 dB, 90 dB, 90 dB setting. Above considerations in mind, it is suggested that exchange rate and threshold level be specified in related laws and regulations in the evaluation of working environments noise.

  • PDF

아파트 건설노동자 소음 노출평가 (Assessment of Apartment Building Construction Workers' Noise Exposure)

  • 강태선
    • 한국산업보건학회지
    • /
    • 제33권3호
    • /
    • pp.308-316
    • /
    • 2023
  • Objectives: The aim of this study is to measure and assess the occupational noise exposure levels among construction workers at apartment building construction sites in South Korea. Methods: Noise exposure assessments were conducted for 139 construction workers across 10 different trades at 53 apartment building construction sites in the northern part of Gyeonggi-do. Assessments were carried out using a noise dosimeter set with a 90 dB criterion, an 80 dB threshold, and a 5 dB exchange rate over a period of more than 6 hours(LMOEL) Results: The mean LMOEL (equivalent continuous noise level over 8 hours) for the 139 dosimeter samples was 87.8 ± 4.3 dBA. The mean noise exposure level for each construction trade, referred to as the trade mean, was also calculated. Significant differences in noise exposure levels were observed between construction trades (ANOVA, p < 0.001). The highest LMOEL values were recorded for concrete chippers (93.2 ± 2.6 dBA), followed by ironworkers (88.4 ± 0.7 dBA), concrete finishers (88.3 ± 2.7 dBA), masonry workers (87.7 ± 1.9 dBA), pile driver operators (85.6 ± 1.7 dBA), concrete carpenters (84.9 ± 2.4 dBA), interior carpenters (83.5 ± 2.1 dBA), and other groups (81.4 ± 2.2 dBA). Conclusions: The findings suggest that nearly all construction workers in this study are at risk of Noise-Induced Hearing Loss (NIHL). Moreover, the study establishes that construction trades can serve as a useful metric for assessing noise exposure levels at apartment construction sites.

일부 터널건설현장 근로자의 소음노출 수준에 대한 고찰 (Characteristics of Noise Exposure Level on Workers of Tunnel Construction Sites)

  • 김갑배;장재길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.739-744
    • /
    • 2013
  • The aim of this study is to evaluate the noise level from the machines used for tunnel construction and to analyze the noise exposure level of workers engaged in tunneling works. The sound level meter and noise dosimeters was used for the monitoring of noise in the tunneling work sites. The average noise from jumbo drill was 113.0 dE(A), the noise from pay loader was 92.4 dB(A), the noise from backhoe was 99.9 dB(A) and the noise from shotcrete machine was 94.3 dE(A). The tunneling workers were exposed to 66.9~94.9 dB(A) of noise and other workers exposed to less than 90 dB(A) of noise. Jumbo drill operators were exposed to to 82.5~84.2 dB(A) of noise, backhoe operators were exposed to 70.2~94.9 dB(A) of noise, shotcrete machine operators were exposed to 68.2~74.7 dB(A) of noise and pay loader operators were exposed to 59.2~81.3 dE(A) of noise.

  • PDF

터널공사현장 근로자의 소음노출 특성 평가 (Exposure Characteristics to Noise Among Tunnel Construction Workers)

  • 김갑배;장재길
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.831-840
    • /
    • 2013
  • The noise levels of workers in tunnel sites are likely to be high because tunneling work places are confined space. However, research on the noise exposure levels of tunneling workers have not been performed intensively due to restricted accessibility to tunnel construction sites. The aim of this study is to evaluate the noise exposure levels for workers engaged in tunneling work sites. Noise dosimeters were used for monitoring workers' noise exposure level in 5 tunneling work sites in accordance with the Notification of the Ministry of Labor. Among 5 tunneling work sites, 4 of them used NATM tunneling method and 1 work site used shield TBM tunneling method. The average noise exposure levels of NATM tunneling workers was 81.1 dB(A) and 15.4 % of the workers' noise level were exposed more than 90 dB(A) which is the exposure limit value. In Shield TBM tunneling method, 4.3 % of the workers were exposed more than 90 dB(A) of noise level, the average noise exposure levels of TBM tunneling workers was 84.1 dB(A).

Noise Exposure Assessment in a Dental School

  • Choosong, Thitiworn;Kaimook, Wandee;Tantisarasart, Ratchada;Sooksamear, Puwanai;Chayaphum, Satith;Kongkamol, Chanon;Srisintorn, Wisarut;Phakthongsuk, Pitchaya
    • Safety and Health at Work
    • /
    • 제2권4호
    • /
    • pp.348-354
    • /
    • 2011
  • Objectives: This cross-sectional study was performed in the Dental School of Prince of Songkla University to ascertain noise exposure of dentists, dental assistants, and laboratory technicians. A noise spectral analysis was taken to illustrate the spectra of dental devices. Methods: A noise evaluation was performed to measure the noise level at dental clinics and one dental laboratory from May to December 2010. Noise spectral data of dental devices were taken during dental practices at the dental services clinic and at the dental laboratory. A noise dosimeter was set following the Occupational Safety and Health Administration criteria and then attached to the subjects' collar to record personal noise dose exposure during working periods. Results: The peaks of the noise spectrum of dental instruments were at 1,000, 4,000, and 8,000 Hz which depended on the type of instrument. The differences in working areas and job positions had an influence on the level of noise exposure (p < 0.01). Noise measurement in the personal hearing zone found that the laboratory technicians were exposed to the highest impulsive noise levels (137.1 dBC). The dentists and dental assistants who worked at a pedodontic clinic had the highest percent noise dose (4.60 ${\pm}$ 3.59%). In the working areas, the 8-hour time-weighted average of noise levels ranged between 49.7-58.1 dBA while the noisiest working area was the dental laboratory. Conclusion: Dental personnel are exposed to noise intensities lower than occupational exposure limits. Therefore, these dental personnel may not experience a noise-induced hearing loss.

자동차검사 공정 근로자의 소음노출 특성 (Workers' Exposure Characteristics to Noise in Car Inspection Processes)

  • 장재길;김종규
    • 한국소음진동공학회논문집
    • /
    • 제24권11호
    • /
    • pp.854-860
    • /
    • 2014
  • Workers engaged in car inspection works have been exposed to many occupational hazards including noise, particulate matter, and volatile organic substances. Noise-induced hearing loss(NIHL) is one of the leading health hazards among Korean workers. The aim of this study is to evaluate the noise levels in several car inspection shops by introducing the evaluation methods of KMOEL/OSHA and ACGIH. Six sites in central area of Korea were selected to monitor the noise levels of workers by personal and area sampling methods for two consecutive days in spring, summer, fall and winter seasons. Dosimeters have been used for this noise monitoring program. Obtained noise levels by the evaluation method according to KMOEL/OSHA are the range of 50.2~88.2 dB(A), these are lower than KOEL/OSHA standards level of 90 dB(A). But highest noise by ACGIH's evaluation methodology is recorded 92.3 dB(A) and is greater than NIHL standard level of 85 dB(A). So that many workers may be exposed to the dangerous noise environment. The higher the car inspection loads daily, the higher the noise levels in the sites. Seasonal fluctuation of noise levels at the process might give monitoring results with high variations. Area noise levels showed higher than those of personal sampling, which illustrate some high noise spots in the car inspection areas.

자동차 프레스 공정에 있어서 직무 및 누적소음기 설정치 차이에 따른 작업자의 소음노출 평가 (An Assessment of Notice Exposure by Job and Dosimeter Parameters Setting in Automobile Press Factory)

  • 정지연;박승현;이광용;이나루;유기호;박정선;정호근
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.190-197
    • /
    • 2001
  • Noise-induced hearing loss(NIHL) was the highest rate (43.5%~58.5% from 1996 to 1998) of positive findings through specific medical program in Korea. There were much more NIHL at workers of automobile manufacturing factories than other manufacturing factories. The specific aim of the present study was to determine the noise exposure of automobile press lines, according to their job titles, press line types(auto, semiauto), dosimeter parameters setting. There were a total 11 press lines sampled at a automobile manufacturing company. Among those press lines, 10 press lines were autolines with acoustic enclosure, one semiauto press line was no aucostic enclosure Noise exposure data were sampled for an work shift using noise dosimeter, which recorded both time-weighted average(TWA) and 1-min average. The mean OSHA TWA(Korea TWA with threshold 90) was $80.7dB(A){\pm}4.7dB(A)$ for leader, $82.8dB(A{\pm}4.5dB(A)$ for pallette man, $76.7dB(A){\pm}4.3dB(A)$ for press operators, $76.6dB(A){\pm}5.6dB(A)$ for crane operators, $77.1dB(A){\pm}2.8dB(A)$ for forklift drivers, whereas the mean NIOSH TWA was $88.9dB(A){\pm}1.7dB(A)$ for leader, $89.6dB(A){\pm}2.1dB(A)$ for pallette man, $86.7dB(A){\pm}1.8dB(A)$ for press operators, $88.5dB(A){\pm}2.0dB(A)$ for crane operators, $87.7dB(A){\pm}1.0dB(A)$ for forklift drivers. While L10 for NIOSH TWA samples was 84.8 dB(A) ~ 87.3 dB(A), L10 for OSHA TWA samples was 69.5 dB(A) ~ 77.4 dB(A). L10 means that the TWA for 90% of the samples exceeded L10. Among OSHA TWA(Korea TWA with threshold 90) samples for pallette man, 7.7 % exceeded 90 dB(A), the OSHA permissible exposure level, but OSHA TWA samples for the other job titles didn't. Among NIOSH TWA samples, the samples over 85 dB(A), the NIOSH recommended exposure limit, was 100% (leaders), 83.3 %(operators), 97.4%(palletteman), 100%(forklift drivers), 91.7 %(crane operator). The results of One-way random effects analysis of variance models shows that the difference between job titles was significant by OSHA TWA(p<0.05), but not significant by NIOSH TWA(p>0.05). NIOSH TWA samples were significantly higher than OSHA TWA samples(P<0.05). Regression analysis was used to obtain relationships between OSHA TWA samples and NIOSH TWA samples. In this case the coefficient of determination = 0.90, which shows the high degree association between two methods. Regression equation, NIOSH TWA = 0.552 * OSHA TWA + 42.13 dB(A), shows that if OSHA TWA is known, NIOSH TWA can be predicted by the equation. The mean TWA difference between threshold 80 dBA and 90 dBA was significant(p<0.01). While the TWA noise exposures were 7.7% above the Korea(OSHA) PEL, they were more than 83.3% over NIOSH REL. Automobile workers were exposed to noise level that could be potentially damaging to their hearing. It found that there is approximately 25% excess risk of hearing loss even if a worker is protected to the PEL in according to NIOSH study.

  • PDF

X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구 (A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner)

  • 정재용;이충일;민정환;김연래;이성용;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2010
  • CT 촬영 장치를 기반으로 한 MAGAT (Methacrylic Acid, Gelatin gel And THPC) 정상 산소 중합체 겔 선량계의 화합물 조성비와 CT 영상 스캔 인자의 변화에 따른 선량 반응성을 평가하였다. 다양한 농도의 메타크릴산(MAA, MethAcrylic Acid)과 젤라틴을 조성하여 MAGAT 선량계를 제작하고 20 Gy까지의 방사선을 조사하였다. 조사된 겔 선량계는 CT 촬영 장치(Brilliance Big bore scanner, Phillps, Netherlands)를 이용하여 다양한 스캔 인자(관전압, 관전류, 단면두께)로 같은 위치에서 20회까지의 CT 영상을 획득하였다. 획득된 영상으로 $N_{CT}$-선량 반응곡선($N_{CT}$-dose response), 선량 감도(dose sensitivity), 선량 분해능(dose resolution)을 측정, 평가하였다. 각 조성비 별 MAGAT 선량계의 $N_{CT}$-선량 반응곡선에서 메타크릴산과 젤라틴의 양이 증가함에 따라 기울기와 절편이 증가하였다. 선량 감도는 $0.338{\pm}0.08$에서 $0.859{\pm}0.1$까지 나타났고 메타크릴산이 증가, 젤라틴이 감소할수록 증가하였으나 그 변화는 메타크릴산 농도의 증가에 따라 감도가 증가되는 것에 비해 아주 작은 변화를 보였다. 선량 분해능은 약 2.6에서 6 Gy까지 다양하게 나타났으며 감도와 영상 내의 노이즈에 의해 큰 변화를 보였다. 영상 스캔 인자의 변화에 대한 반응곡선은 관전압, 관전류, 단면두께의 변화에 따른 곡선의 기울기와 감도는 큰 변화를 보이지 않았으나 영상 내의 노이즈(평균 CT number의 표준편차)는 위의 3개의 인자가 증가할수록 감소함을 보였다. 본 연구는 CT 촬영장치를 이용한 MAGAT 중합체 겔의 선량 반응성을 평가하여 적정한 조성비와 스캔 인자를 얻을 수 있었으며 CT를 기반으로 한 3차원 선량계를 간단하고 효율적으로 임상에 적용할 수 있을 것으로 사료된다.

흉부방사선검사의 목표노출지수 설정을 위한 연구 (A Study to Establish Target Exposure Index for Chest Radiography)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.167-173
    • /
    • 2024
  • This study purpose to establish an appropriate target exposure index(EIT) using dose area product(DAP) and exposure index(EI) based on chest radiography. First, the system response experiment was conducted with radiation quality of RQA5 to compare the dosimetry and dose area product of equipment. Next, EI and DAP were acquired and analyzed while varying the dose in the diagnostic at 70kVp using a human body model phantom. The signal to noise ratio(SNR) of the obtained results was analyzed in the diagnostic with in the diagnostic reference level(DRL) application range. The DRL at percentage 25% had a dose of 0.17 mGy and EI was 83, and at percentage 75% the dose was 0.68 mGy and EI was 344. As the dose increased, the SNR in the subdiaphragm increased. To set the EIT, calibration must first be performed using a dosimeter and set within the DRL range to reflect the needs of the medical institution.

두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구 (A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT)

  • 김기원;오주영;민정환;이상선;이영봉;임경환;이윤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.