• Title/Summary/Keyword: Noise Control Facilities

Search Result 46, Processing Time 0.025 seconds

A Study on Cost-Benefit Analysis of Noise Control Facilities using Road Traffic Noise Map (도로교통 소음지도를 이용한 소음저감시설의 비용 / 효과 분석방법 연구)

  • Kim, Ji-Yoon;Park, Sang-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.303-310
    • /
    • 2008
  • In Korea, the current noise impact assessment has not yet considered the vertical noise propagation property by buildings and other obstacles. And noise control plan has been established without conducting the economic assessment for the noise control facilities. A noise map is used to calculate the noise level based on a theoretical formula or an empirical formula, and also predict the characteristics of vertical propagation by linking with a geometry data. And It is Possible to analyze cost-effect of noise control facilities by consider installation costs. In this study, we addressed the application of noise map for noise impact assessment and cost-effect analysis of noise control facilities.

  • PDF

Reducing Effect of Traffic Noise Soundproof Facilities (방음시설의 소음저감효과에 관한 연구)

  • Jeon, Gi-Seong;Park, Young-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • In order to propose the design and installation information of vegetation belt, field investigation were carried out in the noise pollution control facilities of highway and the streets of a city for two years(1998~1999), and field tests were performed to analyze the noise attenuation effect of them. The noise pollution control facilities were generally classified into three types (noise barrier and vegetation belt type, mounding and vegetation belt type, vegetation belt type only). Most soundproof facilities were proved the noise reduction effects. But according to width, height, structure, auditory distance and planting forms of them, difference of noise reduction effects were investigated. The soundproof facility was suitable the mounding and vegetation belt type in the consideration of road environment, and the installation standard of vegetation was estimated that the width of vegetation was at least 20m and the length of that was 2 times in the distance from noise source.

  • PDF

A study on Traffic Noise control by the Environmental facilities around Roadway (도로연변 환경시설에 의한 교통소음 저감방안에 관한 연구)

  • Sul Jeung Min;Chung Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.3 no.2 s.5
    • /
    • pp.43-60
    • /
    • 1988
  • This study was carried out to determine traffic noise level and analyze noise reduction effects of various sound protection facilities in the area of Seoul, Inch'on, Songchoo and Seoul- Busan Expressway from March to Octover, 1987. The results were as follows; 1. As compared with the environmental standards and the traffic noise level in heavy noise areas, traffic noise levels observed were shown in higher than environmental standards. The noise levels in Seoul were determined at 12.8-18.2 dB(A) in daytime and 19.0-26.9 dB (A) in nighttime. And incase of inch'on, it were 6.7-9.6 dB(A) in daytime, 7.9-18.9 dB(A) in nighttime, respectively. 2. The environmental noise level observed in the backside of protection facilities, such as apartment, soundproof barrier and houses, which were constructed in paralled to the road was lower about 3-5 dB(A) than perpendicular to theroad. Noise recuction effect of upper stairs in apartment was higher than lower stairs. 3. The predicted noise level obtained from the equation $({\triangle}L\;=\; -10\;log\;(^{I'1}/Ii)\;was\;\pm\;1dB$ (A) and the correlation coefficient (r) was 0.923. 4. The noise reduction effect in backside of apartment was measured at on sites and predicted by total noise loss equation. The predicted noise level was 60.9 dB(A) and the measured level was 60.6 dB(A), respectively. 5. The narrow width landscape less than 10m width was almost no effect for the protection of traffic noise. According to the synthesis of the above results, the noise level of the road was exceeding mostly the environmental standard in the heavy traffic areas. The counterplan should be set as well. The insulation of noise protection facilities were effective by the location with near distance from the road edge. The reduction effect of double window in apartment was represented so much. The prediction model could be applied to estimate the noise levels in the roadside as well as the effectiveness for the noise protection facilities.

  • PDF

Development of the equipment for detecting the poor power facilities by receiving electric noises (전자파 잡음을 이용한 전기설비 불량 검출장치 개발)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

A Noise Control of a Floating, Production, Storage and Offloading (FPSO) (부유식 석유생산/저장/하역 선박(FPSO)의 소음예측 및 저감)

  • Kim, Dong-Hae;Ko, Kyung-Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.550-553
    • /
    • 2004
  • Recently, the demand for the Floating, Production, Storage, and Offloading facility (FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The 36,8000 DWT class FPSO was built in Hyundai Heavy Industries and will be installed in Offshore Angola. She dose not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise sources are contributing to the cabin noise of the accommodation are classified into three classes such as the machinery in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is severer than that of the cargo ship and acceptable noise limit of cabin is specified as 45 dB(A). This paper describes the procedure of noise analysis, the countermeasures of noise control, and the measurement results of the quay trial. In order to minimize the noise levels, careful attention have to be paid by the special committee of experts from the initial design stage to the delivery. Proper countermeasures, considering the characteristics of sources and receiver spaces, were applied from the noise prediction and various experiment results. Finally, this ship was successfully delivered with excellent noise properties. The technology to minimize the noise levels for FPSO has been established throughout the construction of this ship.

  • PDF

A Study on Legislation Related to Noise Countermeasures in Military Airfield (군용비행장 소음대책 관련 입법안에 대한 연구)

  • Kim, Yong-Hun;Hawng, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.32 no.1
    • /
    • pp.355-384
    • /
    • 2017
  • In Korea, a Law on Airport Noise Prevention and Noise Control Area Support has been in effect since 2010. And also, airport noise measures project and residents support project conducted following the Law on Airport Noise Prevention and Noise Control Area Support. However, a Law on Airport Noise Prevention and Noise Control Area Support does not apply to military airfield. Many city residents already complain about military airport noise, but there are no countermeasures. They claim the noise from the military airfield is an intrusion on their lives, and some people brought a class action against the government. In the 20th National Assembly, some congressmen already proposed some legislations that aims to support residents adjacent to the military airfield. Nevertheless, relevant legislations are currently pending at the 20th National Assembly. Legislation preventing aircraft noise and providing support measures is essential to residents life who near by military airfield. At first, this study looked at legislations proposed by congressmen in the 20th National Assembly. And also, this study looked at A Law on the Improvement of Living Environment around the Defence Facilities of Japan. Based on this study, we did an analysis of the problem of legislation and proposed improvement suggestion. I hope so that this study could someday help congressmen make a legislation about military airfield noise. We hope the 20th National Assembly will pass the legislation finally to help the residents who near by military airfield relieve their pain by noise and restore their human dignity.

  • PDF

Stabilization of High-Voltage Static Var Compensator Using Switching Velocity and Temperature Control (스위칭 속도 및 온도 제어를 사용한 고압용 정지형 무효전력 보상장치의 안정화)

  • Kim, Yong-Tae;Lee, Chang-Seok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • In the paper, velocity controller of switching module and temperature controller for the high-voltage static var compensator are proposed. Because of the continuous increase in demand for electric power, transmission and distribution facilities of power plant are required. There is a bottleneck problem of transportation routes according to new construction and expansion of power transmission facilities. Therefore there are researches to maximize the utilization of existing facilities and to increase transmission capacity without new construction. The previous static var compensator detects voltage of input circuit of power, switches the SCR directly and generates switching noise. The proposed method increases switching velocity and decreases noise using switching control based on the voltage between both sides of SCR. Also the proposed method enhance the stability using realtime temperature control for heating of the system from increase of switching velocity. We experiment the velocity and temperature control of the proposed high-voltage static var compensator in the real environment and verify the performance of the proposed system by applying in the real field.

Power plant instrumentation and control system by using optical fiber cable (광케이블을 이용한 발전소 계측제어시스템)

  • 신건학;조홍근;오면택
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.79-84
    • /
    • 1990
  • Analog systems could not fully deal with instrumentation and control facilities in power plants since these facilities have become more and more complex on account of various needs for large power generation capacity highly cost effective operation to conserve energy and operation management to prevent pollution. Digitalizations of control device and augmentations of control informations increased the necessity of fiber optic data networks which have excellent noise immunity and high quality wide-band with information transfer capability. The goal of this study is to offer a fiber optic data-way system which has high reliabilities, high data transmission rates and small cable ducts with large transmission capacities for the instrumentation and control of power plants.

  • PDF

Design and Implementation of Wireless Transceiver Module for Parking Control System (주차관제를 위한 무선 송수신 모듈 설계 및 구현)

  • Cho, Byung-Hak
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.1
    • /
    • pp.24-29
    • /
    • 2009
  • In this paper, we show the implementation of the low-cost RF transceiver module for parking control system. Super regenerative receiver scheme was adopted for this module due to its simplicity, low-cost, low power consumption and small number of components to improve reliability of the systems. For improving communication error rate by collision and in-band noise, dual-channel hopping scheme was adopted. Testing prototypes under the environment of simultaneous transmissions, we verified that the designed scheme is able to improve the success rate of data transmission of wireless parking control system cost effectively.

  • PDF

Evaluation of Outdoor Community Facility in Rental Apartment For Community Space Activation (커뮤니티공간 활성화를 위한 임대아파트의 외부 커뮤니티시설 계획 특성에 관한 연구)

  • Hwang, Yeon Sook;Lee, Song Hyun;Eo, Sung-sin
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.69-76
    • /
    • 2009
  • The purpose of this study is to provide basic data needed for planning and designing apartment community facilities in order to vitalize rental apartments. Outdoors community facilities of six rental apartments in Seoul were examined. The results are as follows. Firstly, the conditions of planning characteristics showed that the convenience is ranked as the highest priority of planning, compared to safety, friendliness and finally comfortableness. Community facilities are connected with the apartments and sidewalk providing convenient access for all apartment residents, there was little regard given to the features of comfortableness. Secondly, comfortableness of community facilities were shown to the lowest, compared to any characteristics. It is not easy to control noise and privacy in facility, and there are lack of near community facilities, for washing hands, drinking water and shielding from snow or rain, respectively. Thirdly, green facilities were shown to the highest applied friendliness more than other facilities. They were well outfitted with water space and gardening spaces, and robustly applied environment friendly materials and colors. Fourthly, resting facilities were shown to the lowest applied safety more than other facilities. Structure and material of facility are favorable but there is an absence of nonskid material and night-lightening system.