• Title/Summary/Keyword: Nodules

Search Result 1,197, Processing Time 0.024 seconds

Morphological Redescriptions of Three Condylostoma Ciliates (Heterotrichida: Condylostomatidae) New to Korea

  • Kim, Ji-Hye;Jang, Seok-Won;Shin, Mann-Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • v.28 no.3
    • /
    • pp.149-160
    • /
    • 2012
  • Heterotrichous ciliates were isolated from marine and brackish habitats in Korea, and their morphology, infraciliature and morphometrical characters were investigated using silver impregnated methods. These three Condylostoma species were identified as Condylostoma curva Burkovsky, 1970, C. minutum Bullington, 1940 and C. spatiosum Ozaki and Yagiu in Yagiu, 1944. The species of Condylostoma based on morphology are highly variable in most of characters and distinguished as following. Condylostoma curva is oval to elongate ellipsoidal, size about $245{\times}100{\mu}m$ in vivo, and conspicuously dark greenish brown with cortical granules on their surface, buccal cavity relatively large about 40% of body length, 5-11 macronuclear nodules, 4-8 frontal cirri serially arranged and 22-38 somatic kineties. Condylostoma minutum is elongate ellipsoidal and the size about $310{\times}55{\mu}m$ in vivo, buccal field about 35% of body length, 12-20 macronuclear nodules, adoral zone consisted of 82-107 membranelles, large and long one frontal cirrus and 38-44 somatic kineties. Condylostoma spatiosum is large elongate ellipsoidal, size about $670{\times}105{\mu}m$ in vivo, buccal cavity about 25% of body length, 11-25 macronuclear nodules, 111-144 adoral membranelles, membrane-like 2 frontal cirri, 49-74 somatic kineties. These three Condylostoma species are described here for the first time in Korea.

Analysis of Transthoracic Fine Needle Aspiration Cytologic Diagnoses of Pulmonary Nodules (폐장 결절성 병변에 대한 경흉 세침천자 세포학적검사 결과의 분석)

  • Park, Chan-Kum;Lee, Jung-Dal
    • The Korean Journal of Cytopathology
    • /
    • v.6 no.2
    • /
    • pp.133-139
    • /
    • 1995
  • To evaluate the sensitivity and specificity of transthoracic fine needle aspiration cytology(TFNAC) in the preoperative diagnosis of pulmonary nodules, a retrospective analysis was carried out on a consecutive series of 200 TFNACs. They included 186 primary malignant tumors, 66 squamous cell carcinomas, 65 adenocarcinomas, 36 small cell carcinomas, 7 large ceil carcinomas, 4 carcinomas, 8 others, 9 metastatic tumors, and 5 benign tumors. On cytohistologic correlation of malignant pulmonary tumors, the procedure had a sensitivity of 97.3% and a specificity of 100%. A 86.6% correct correlation between the cytologic and histologic diagnoses was achieved. Five out of the 7 undifferentiated large cell carcinomas, 10 out of the 65 adenocarcinomas, 2 out of the 36 small cell carcinomas, and 2 out of the 66 squamous cell carcinomas were turned out to be mistyped in cytologic diagnosis. We concluded that TFNAC is a highly sensitive and specific preoperative diagnostic procedure in the investigation of patients with discrete pulmonary nodules in whom the specific ceil type of the malignant neoplasm has important implications in treatment modality and prognosis.

  • PDF

Fine Needle Aspiration Cytology of Thyroid Nodules: Assessment of diagnostic accuracy and evaluation of each cytologic diagnosis (갑상선 결절의 세침흡인 세포검사: 진단성적의 검토 및 세포학적 진단의 평가)

  • Park, In-Ae;Ham, Eui-Keun
    • The Korean Journal of Cytopathology
    • /
    • v.10 no.1
    • /
    • pp.43-53
    • /
    • 1999
  • We retrospectively reviewed the results of 1,850 fine needle aspiration cytology(FNAC) of thyroid nodules performed from 1990 to 1991 in the Department of Pathology, Seoul National University Hospital. Among 1,528 cases and 322 cases aspirated by clinicians and a pathologist, 465 cases(30.4%) and 13 cases(4.0%) of the aspirates were inadequate, respectively. In 227 cases, correlation of the FNAC diagnosis and histologic diagnosis was done. Excluding the inadequate cases, the sensitivity nor the detection of neoplasm(malignancy together with follicular adenoma) was 86.4% and the specificity was 70.7%. The overall diagnostic accuracy was 79.0%. There were 16 false-positive cases(7.0%), and 19 false-negative cases(8.4%). The predictive value of each cytologic diagnosis was 92% in papillary carcinoma, and 100%, in Hashimoto's thyroiditis. The expectancy of malignancy was 52.8% in "suspicious malignancy" and 26.7% in "atypical lesion".

  • PDF

Clinical Experience of Polypoid Idiopathic Scrotal Calcinosis (용종성 특발성 음낭부 석회증 환자의 임상적 경험)

  • Kim, Kook Hyun;Choi, Hwan Jun;Kim, Mi Sun;Jung, Sung Kyun
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.241-244
    • /
    • 2006
  • Idiopathic scrotal calcinosis is rare entity, characterized by the presence of multiple, firm nodules within the dermis of scrotal skin. The lesions are evident as asymptomatic, round, firm, yellowish papules, from several millimeters up to 1 cm in diameter, with a tendency to occur symmetrically. Because polypoid formation of the calcified cysts is unusual in scrotal calcinosis, we report our experience of a case of scrotal calcinosis with cysts having polypoid appearence. A 34-year-old man was admitted to our department with painless, firm, widespread nodules within the scrotum. Patient started to have these lesions at puberty and progressed to a polypoid form over time. There was neither surgical nor medical treatment had been attempted before our treatment. Physical examination revealed localized polypoid cysts in addition to multiple small, firm nodules within the scrotal skin. No underlying anomalies were detected in the physical examination and laboratory analysis. We experienced the treatment of polypoid idiopathic scrotal calcinosis and a case is presented with the review of literatures.

Classification of Ground-Glass Opacity Nodules with Small Solid Components using Multiview Images and Texture Analysis in Chest CT Images (흉부 CT 영상에서 다중 뷰 영상과 텍스처 분석을 통한 고형 성분이 작은 폐 간유리음영 결절 분류)

  • Lee, Seon Young;Jung, Julip;Lee, Han Sang;Hong, Helen
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.994-1003
    • /
    • 2017
  • Ground-glass opacity nodules(GGNs) in chest CT images are associated with lung cancer, and have a different malignant rate depending on existence of solid component in the nodules. In this paper, we propose a method to classify pure GGNs and part-solid GGNs using multiview images and texture analysis in pulmonary GGNs with solid components of 5mm or smaller. We extracted 1521 features from the GGNs segmented from the chest CT images and classified the GGNs using a SVM classification model with selected features that classify pure GGNs and part-solid GGNs through a feature selection method. Our method showed 85% accuracy using the SVM classifier with the top 10 features selected in the multiview images.

MR Imaging of Disseminated Tuberculosis of the Brain in a Patient with Miliary Tuberculosis : Initial Findings and Changes Six Months after Antituberculous Therapy (속립성 뇌결핵의 초기 자기공명영상 소견과 치료 후 변화)

  • Jang, Jae Ho;Lim, Jae Woo;Jung, Soon Lee;Choeh, Kyuchul;Han, Taeil
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1596-1600
    • /
    • 2002
  • A 23-month-old girl visited with chronic cough and her chest radiograph showed miliary tuberculosis. There was no neurological abnormality. But CSF findings showed WBC $22/mm^3$(lymphocyte 20%, neutrophil 80%) and positive result of polymease chain reaction(PCR) for M. tuberculosis. MR imaging showed multiple ring enhanced nodules and ovoid nonenhancing bright signal lesion on the cerebrum, cerebellar parenchyme, and left basal ganglia. Antituberculous chemotherapy was done and follow-up MR imaging was done after six months. One month after treatment, the number and size of nodules had decreased. Six months after treatment, the multiple enhanced nodules and leptomeningeal enhancement were not observed, and high signal intensity of genu portion of left internal capsule and posterior portion of putamen were decreased.

A Study on Pick-up Device of Beep Sea Manganese Nodules Collector (심해저 망간단괴 집광기의 채집장치에 관한 연구)

  • Hong, Sub;Sim, Jae-Yong;Lee, Tae-Hee;Choi, Jong-Soo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.891-895
    • /
    • 1996
  • Performance and efficiency of hybrid (hydraulic-mechanical) pick-up device of deep sea manganese nodules collector are very sensitive to altitude and altitude of pick-up head relative to undulating seafloor. For this reason, motion control of pick-up head relative to the changing deep sea topography and other disturbances is of particular importance in design of pick-up device. The concept of design axiom is applied to a pick-up device of hybrid type. Kinematic analysis conducted in absolute Cartesian coordinates gives position, velocity, and acceleration of the hydraulic cylinders which enable the pick-up head to keep the preset optimal distance from seafloor. Inverse dynamic analysis provides the driving forces of hydraulic cylinders and the reaction forces at each joint. Design sensitivity analysis is performed in order to investigate the effects of possible design variables on the change of the maximum strokes of hydraulic cylinders. The direct differentiation method is used to obtain the design sensitivity coefficients.

  • PDF

Design Evaluation of Pickup Device Collecting Deep-Sea-Manganese Nodules (심해저 망간단괴 집광기 채집장치의 설계평가)

  • Choi, Jong-Soo;Lee, Tae-Hee;Hong, Sub;Sim, Jae-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.68-74
    • /
    • 1998
  • Performance and efficiency of deep seabed collector is a primary factor for feasibility of commercial deep ocean mining. The efficiency of manganese nodules collector depends on vehicle mobility relative to undulating seafloor and is attributed pickup head to keep altitude and elevation of it against seafloor. For this reason, motion control of pickup head relative to the changing deep-sea topography and other disturbances is of particular importance in design of pickup device. The concept of design axiom is applied to a pickup device of hybrid type in order to evaluate the concept design. Kinematic analysis conducted in absolute Cartesian coordinates gives position, velocity, and acceleration of the hydraulic cylinders which enable the pickup head to keep the preset optimal distance from seafloor. Inverse dynamic analysis provides the driving forces of hydraulic cylinders and the reaction forces at each joint. Design sensitivity analysis is performed in order to investigate the effects of possible design variables on the change of the maximum strokes of hydraulic cylinders. The direct differentiation method is used to obtain the design sensitivity coefficients.

  • PDF

Observations of lymphoid polyps on the gastrointestinal tract (위장벽(胃腸壁)에 발생(發生)한 Lymphoid Polyps의 병리학적관찰(病理學的觀察))

  • Kwak, Soo-dong
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.2
    • /
    • pp.195-199
    • /
    • 1984
  • The present observations were focussed mainly on the macroscopic and histopathological observation to polyps encountered on the stomach of 4-month-old pig, small intestine of 3-month-old pig and cecum of 9-month-old dog. The results were summarized as follows; 1. The polyps were gray or pink hemispherical shapes attached by the broad base to the gastrointestinal walls and were 3 to 8 mm in diameter and diffuse appearance. The surfaces of polyps were flat or indented and were ulcerated in some large polyps. 2. In histopathological findings, the polyps were nodules composed of lymphoid follicles, which were characterized by the differentiation and proliferation of the lymphoid cells in the lamina propria or submucosa of the gastrointestinal tract. The lymphoid nodules have the thin septa and thick capsules of the connective tissues, also comprised more numerous and larger sinus-like-blood vessels and more diffuse lymphoid cells in the peripheral zones than those in the central zones of nodules. In addition, the external surface of the polyps bulged toward the intestinal lumen were covered with the abnormal epithelium, or the degenerative and necrotic lymphocyte aggregates. 3. These polyps were considered as lymphoid polyps caused by the hyperplasia of the lymhoid follicles.

  • PDF

Studies on the Root Nodule Formation of Soybean Cultivars (재배대두의 근류형성에 관한 조사 연구)

  • 최창열;박종성;김충수
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.23 no.2
    • /
    • pp.105-112
    • /
    • 1978
  • Earliness of the nodule formation was significantly different among soybean varieties. The numbers of the nodules were much various due to the origins of the soybean varieties and the date of observation. The significant positive correlations were shown between the weight of nodule and soybean yield and also between the weight of nodules and number of nodules but the correlations among the other characters were not significant.

  • PDF