• 제목/요약/키워드: No.3 Water-way

Search Result 205, Processing Time 0.035 seconds

THE INFLUENCE OF THE VITAL BLEACHING AGENTS ON TRANSLUCENCY OF THE BOVINE ENAMEL (생활치 미백제가 우치 법랑질의 투명도에 미치는 영향)

  • Kim, Dong-Jun;Kim, Young-Ju;Kim, Hak-Geun;Park, Eun-Jong;Seo, Eun-Ju;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.178-183
    • /
    • 2005
  • This study was done to evaluate whether vital bleaching agents could influence on the translucency of the bovine enamel. The anterior bovine teeth that were extracted one day before and without any gross discoloration were obtained and then were preserved in physiologic saline. 6 mm cylindrical tooth specimens were fabricated with diamond puncher perpendicularly on labial surface of bovine tooth. After embedded in transparent acrylic resin with labial surface being exposed, they were cut to a thickness of 1.2 mm with low speed diamond saw (Isomat, Buehler Co., Lake Bluff, IL, USA). They were smoothly ground to 1 mm thickness of enamel with sandpaper. 24 specimens were randomly divided into 3 groups and control group respectively. Opalescence (10% carbamide peroxide, Ultradent, South Jordan, USA), Rembrandt (10% carbamide peroxide, DenMat, USA) and Opalescence F (15% carbamide peroxide with fluoride, Ultradent, USA) were applied on labial sides of the bovine enamel for 7 days (bleaching agents were reapplied every 24 hours) and the opposite surface was contacted to cotton that soaked in distilled water. The control group was soaked in distilled water. Three stimulus value X, Y and Z were evaluated with colorimeter (Color ' Color Differencerneter, Model TC-6FX, Tokyo Denshoku Co., Japan) on the labial surface of all specimen three times on white and black background plate before the bleaching agents were applied and on 3rd, 5th and 7th day after applied. The degree of translucency was normally assessed by measuring the inverse property, opacity (contrast ratio). 10% Opalescence, 15% Opalescence-F, and control group showed no significant variation in the translucency of bovine enamel, However Rembrandt decreased the translucency of it (p < 0.01).

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

A Study on $Na^+$ and Water Reabsorption in the Nephron Segment Beyond Proximal Tubule Measured by Lithium Clearance

  • Han, O-Soo;Goo, Yong-Sook;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.189-200
    • /
    • 1991
  • During the past few years it has been proposed that lithium clearance can be used as a reliable measure for the outflow of tubular fluid from the proximal tubule. This study was aimed to characterize the inflow dependent reabsorption of Na in renal tubule beyond the proximal tubule. For this purpose, lithium clearance was used as a measure for the inflow from the proximal tubule and the changes in reabsorption fraction of Na and water were determined in rabbits. Rabbits were pretreated with hypotonic saline solutions for an hour (50 mM/L NaCl, 20 ml/hr/kg). And then a hypertonic solution of 500 mM/L NaCl (20 ml/kg) was administered intraperitoneally in conjunction with a bolus of LiCl solution (2 mM/kg, i.v.) for conditioning the $C_{Li}$ and urine flow rate. To rule out the effect of $Li^+$ on tubular functions, a bolus of NaCl solution (2 mM/kg, i.v.) was administered. Fifteen, thirty, and sixty minutes after injection of hypertonic saline arterial blood and urine samples were taken. Urinary and plasma concentrations as well as urinary output of $Li^+,\;Na^+\;and\;K^+$ were measured. From these $C_{Li},\;C_{Na}$ and the reabsorption fraction of Na and water $(Fr_{Na}\;&\;FrH_2O)$ were calculated. These results were compared with those from control groups in which the same amount of isotonic saline (145 mM/L NaCl) and of 15% dextran solution were administered in the same way as that in experimental group. Followings are the results obtained. 1) The plasma concentration of $Na^+$ in rabbits injected with hypertonic saline reached the peak value after 15 min and thereafter no significant change was observed. Hematocrit values did not show any change, while urinary excretion of $Na^+$ increased markedly during the first 15 min and decreased thereafter. These results were not affected by an injection of a small amount of LiCl. 2) The clearances of $Li^+,\;Na^+\;and\;K^+$ in rabbits injected with hypertonic saline and LiCl solution decreased. 3) In spite of the variation in $C_{Li},\;Fr_{Na}$ did not show any significant change while $FrH_2O$ increased gradually. 4) $C_{Li}$ decreased also in rabbits received isotonic saline. $Fr_{Na}$ tended to be higher than that in hypertonic saline group, while $FrH_2O\;and\;Fr_{Na}$ did not associated with the decrease in $C_{Li}$. 5) $C_{Li}$ of the rabbits received dextran solution fluctuated persistently and $Fr_{Na}\;and\;FrH_2O$ did not change in along with $C_{Li}$ although $Fr_{Na}$ had a tendency to be higher than that in hypertonic saline group. 6) From the above results it was concluded that: (a) In rabbits with normal body store of $Na^+$, the $Fr_{Na}$ of renal tubule beyond proximal tubule. calculated from $C_{Li}$ as a measure of inflow from proximal tubule is constant in spite of variations in $C_{Li}$. (b) The $FrH_2O$ calculated from $C_{Li}$ is dependent largely upon ADH rather than inflow from proximal tubule. (c) When there is a decrease in plasma $Na^+$ concentration or ineffective body fluid. $Li^+$ reabsorption may occur in the thick segnent of Henle's loop and hence the determination of $Fr_{Na}$ and $FrH_2O$ will not be easy one, but $Fr_{Na}$ is constant under the same experimental conditions.

  • PDF

THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS (구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구)

  • Park, Yeon-Hong;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

A Study on Jeju High School Students' Health Perception and Health Promotion Behavior (제주지역 고등학생의 건강지각과 건강증진 행위에 관한 연구)

  • Kim, Ok-Sun;Choi, In-Sook
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.3
    • /
    • pp.79-110
    • /
    • 2002
  • The purpose of this study was to provide basic data necessary for creating a more successful health enhancement program, health education and health policy which can enhance health management abilities and enable a healthy school life by examining relations between high school students' health perception, who are in early adolescence, and their health promotion behavior. The subjects in this study were 813 students from 8 high schools on Jeju Island. The collected data were analyzed with t-test and one-way ANOVA through questionnaires by researcher on the basis of advance research. The findings of this study were as belows : 1. When general characteristics were considered, health perception was more significantly affected by those who were boys, whose family income was on a higher level, who scored better in school, whose parents were more concerned about their children's health, and who had experiences of being hospitalized. Especially, the more parents were concerned about their children's health, the higher the child's self-confidence on health(p<.05), anxiety on health(p<.05), practicality on disease prevention(p<.05), self-confidence on future health(p<.01), health care ability(p<.01), and family roles on health(p<.05). The less parents were concerned about their children's health, the higher the child's anxiety on disease(p<.01) and uncertainty on future health(p<.01). 2. When students' health promotion behavior was concerned, in the area of Eating Habits, having regular meals(72.9%), moderate consumption of meat(89.7%) and a balanced diet(64%) were common, whereas having a regular breakfast(37.4%) and eating vegetables and fruits(43.6%) were rare. In the area of Exercise, all subareas such as exercising 3 or 4 times a week(76.7%), more than one hour of exercise at a time(74.9%), a short distance walk(51.8%), exercise within one hour after meals(87%), and whether wanning up or not(88.6%) were above average. In the area of Personal Hygiene, all subareas such as drinking boiled water(57.3%), washing hands after using the bathroom(71%), brushing teeth after eating(42.4%), washing up after going out(50.3%), and washing hair and taking a frequent bath(77.2%) were rare. In the area of Control of Personal Relations, consulting personal problems with family(78.7%) had a positive response, whereas meeting someone new(59.8%), maintaining sound relations with the opposite sex(47.3%), having respect for one's opinion(51.5%), and maintaining peaceful relations with people(58.4%) had rare negative results. In the area of Stress Management, not being competitive(69.4%), releasing problems(62.4%) and sleeping soundly(66.2%) were common, whereas having your own ways to relieve stress(46.8%) and having your own dreams and hopes(58.5%) were rare. 3. When general characteristics were considered, as far as relations of health promotion behavior were concerned, the boys were significantly different in the area of Eating Habits(p<0.01) and Exercise(p<0.01), and the girls were in the area of Personal Hygiene. As family economic status was high and parents were concerned about their children's health, the entire areas of health promotion behavior were significantly different. Whether or not they were hospitalized made no significant difference in statistics. 4. When their regions were considered, it comparing city to town, there was no statistically significant difference in health perception and relations of health promotion behavior according to general characteristics. As seen in the results above, high school students' level of health perception and level of practicing health promotion behavior were generally low. In conclusion, by enhancing health perception, a plan for activating health education, which can implement positive health promotion behavior, should be made.

  • PDF

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

Present Status and Future Prospect on Fishing Industry in North Korea (북한수산업(北韓水產業)의 현황(現況)과 전망(展望))

  • Lee, Byoung-Gee;Kim, Jin-Kun;Choe, Jong-Hwa
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.3 no.2
    • /
    • pp.73-82
    • /
    • 1991
  • In recent years, the communication and the trade between the Republic of Korea(South Korea) and the Communist bloc has been activated. The simultaneous entrance of South Korea and North Korea to the United Nations will accelerate the political dialogue and also the trade which is indirectly carried out through a third country at present will be turned into direct way. Fisheries products are also treated as one of the important trade goods and there is a hopeful prospect that the amount of trade will be steeply increased in the near future. Furthermore, there is a great possibility of development up to the joint utilization of fishing grounds or the joint investment in fisheries projects. Concerning such points, since it is very much important to understand the present status of fisheries in North Korea, the author made a study on this field as requested by the Board of Unification, and report a part of the study here. The prominent character of North Korea's ruling sea area is that the sea is completely separated into two regions-the East Sea Region and the West Sea Region-and no continuity exists between them. The East Sea Region locates in the fringe of the biggest fishing ground of the world-the North Pacific Ocean-and very rich in resources not only warm water fishes but also cold water fishes. Especially alaska pollack, Theragra chalcogramma, is caught abundantly in this region. Contrary to that, fishing activity in the West Sea Region seems to be interrupted in winter. Even though some valuable warm water fishes-yellow corvenia, Pseudosciaena manchurica, and hair tail, Trichiurus lepturus, and so forth-come to this region from spring to summer along the coast line of this region for spawning, and vigorous fishing activity is carried out. But the most of them migrate southward to the neighboring waters of Cheju Island for wintering from autumn to winter, and so the fishing activity in this region seems to be interrupted greatly during winter. The total number of fishing boats in North Korea is estimated at 36 thousand and the rate of mechnization at about 70% compared with 99 thousand and 78% in South Korea. North Korea proclaimed an exclusive economic zone of 200 nautical miles in 1977. Specific character of this zone is setting of military boundary zone, up to 50 miles from the base line in the East Sea Region and also it covers whole region of the economic zone in the West Sea Region. Especially in the East Sea Region she set up a straight base line which can not be permissible by the international law. North Korea's statistics on fisheries product has not been announced officially on account of her unique isolationism, but it can be estimated through several data procured. At the first, the amount of fisheries products in the North Korea is reported as about 1.7 million ${\frac{M}{T}}$ by Fisheries Statistics which issued by the FAO in 1987, but a North Korea's trade organization announced the amount as 3.5 million ${\frac{M}{T}}$ in 1988. The former seems to be underestimated and the latter must be an exaggeration. According to Chikuni, who is a Japanese worker for FAO, prepared the unofficial statistics based on the evidence which he collected through the fineries development plan of the FAO/UNDP, and estimated the mean amount between 1982 and 1984 was 2.4 million ${\frac{M}{T}}$ or so. The Board of Unification estimated on the basis of various factors that the amount was 2.2 million ${\frac{M}{T}}$ or so in 1987 and in 1988. This seems to be the most reasonable. To solve the chronic lack of foreign currency, North Korea makes effort on the development of fisheries, and has even aimed fisheries product at 11 million ${\frac{M}{T}}$ by 1993, but this target looks unrealistic under the present circumstances. Somehow, we can exploit her extreme policy which has gone so far as to establish such an excessive and impractical target. Nevertheless this will be helpful to promote the joint development of the fishery activity between South Korea and North Korea.

  • PDF

COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS (수 종의 복합레진 접착 시스템에서의 미세 누출의 비교)

  • Seok, Choong-Ki;Nam, Dong-Woo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.636-644
    • /
    • 2004
  • Recently, self-etching adhesive system have been developed and bonding procedures simplified into one or two steps, which are simultaneously applied to both enamel and dentin. These systems are easy to use and have the potential for good clinical success. The purpose of this study is to evaluate in vitro the microleakage on the cementum/dentin and enamel walls in composite resin restoration of Class V cavities, regarding the use of different adhesive systems. 30 human premolars were divided into 3 groups. A standardized Class V preparation was prepared on the buccal and lingual surface of each premolar. The preparation were made parallel to the cementoenamel junctions, with the gingival half of the preparation extending 1mm apical to the cementoenamel junction. After adhesive system was applied to teeth as manufacture's recommendation, hybrid resin composite was filled in bulk into the preparation and light polymerized according to manufacturer's recommendations. Specimen were stored in distilled water at $37^{\circ}C$ for 5 days and thermocycled 1000 times ($5^{\circ}C{\pm}2^{\circ}C\;and\;55^{\circ}C{\pm}2^{\circ}C)$, then immersed in a 2% methylene blue solution for 12 hours. After sectioning mesio distally through the restorations, the degree of dye penetration was scored under a stereomicroscope at ${\times}\;25$ magnification. The data were analyzed statistically using t-test and one-way ANOVA. The results were as follows: ${\cdot}$ There is no adhesive system which can prevent microleakage perfectly. ${\cdot}$ There is significant difference in microleakage between enamel margin and dentin margin (p<0.0001). ${\cdot}$ In enamel margin, self-etching primer systems did not show any significant difference comparing total-etching system. In denin margin, self-etching primer systems did not show any significant difference comparing one-bottle adhesive system used in combination with total-etching.

  • PDF

Effect of Fluoridated 10% Carbamide Peroxide on Enamel Surface Change and Whitening (불소를 첨가한 10% Carbamide Peroxide의 법랑질표면 변화와 미백효과)

  • Lee, Hye-Jin;Kim, Hyun-Dae;Kim, Min-Young;Kwon, Tae-Yub;Kim, Kyo-Han
    • Journal of dental hygiene science
    • /
    • v.10 no.2
    • /
    • pp.95-100
    • /
    • 2010
  • The purposes of this study were to examine the effect of different fluoridated bleaching solution on the changes in physical and chemical characteristics of tooth. Forty-eight bovine incisors were divided into four groups to receive bleaching treatments, over a 14days period, as follows: no treatment; 10% carbamide peroxide (CP) bleaching; 10% CP containing 0.05% fluoride; and 10% CP containing 0.1% fluoride. All the specimens were highly polished and discolored with commercial COCK.Color and enamel changes were determined with colorimeter, microhardness tester, scanning electron microscope, atomic force microscopy. All the collected data were analyzed with one-way ANOVA. After the bleaching, bleached groups showed the color change(E*). Microhardness of 10% CP group decreased after tooth bleaching. But microhardness of containing fluoride bleached groups increased after tooth bleaching. Enamel surface of 10% CP bleached group showed any apparent morphology and roughness changes compared to the enamel which was stored in distilled water only. These results demonstrated that Fluoridated 10% Carbamide Peroxide have appreciable bleaching effect on bovine teeth and were not adversely affects enamel. Supporting influence of fluoride-containing bleaching solution on remineralization could be observed and further research must be carried out in various active environments to confirm these results clinically.

TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS (티타늄과 금합금의 레이저 용접부의 인장강도)

  • Song, Yun-Gwan;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF