• 제목/요약/키워드: Nitrogen load

검색결과 303건 처리시간 0.019초

Characteristics of Pollution Source Structures and Temporal and Spatial Discharge from the Drainage Basin of a Reclaimed Area (간척지 담수호유역의 오염물질 배출구조 및 시공간적 유출특성)

  • 엄명철;공동수;정동일;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.739-746
    • /
    • 1999
  • Discharge characteristics of organic materials and nutrients were estimated in the catchment area of relaimed area-Saemankeum-. Discharge load of BOD5 was high in the domestic system, while nitrogen and phosphorous were discharged mainly from the livestock system and the land . Load was so dependent on the precipitation that it increased in the rainy season, particulary in nitrogen and phosphorus. Loads from nonpoint sources in this area were higher compared with others.

  • PDF

A study on the application of DOE for optimization of blending oil with non-esterified biodiesel fuel at partial engine load (부분부하에서 비에스테르화 바이오디젤 5% 혼합유의 성능최적화를 위한 실험계획법 적용에 관한 연구)

  • Kim, Hee-Jung;Koh, Dae-Kwon;Yang, Ju-Ho;Koh, Sung-Wi;Kim, Yeong-Sik;Jeong, Tae-Young;Jung, Suk-Ho
    • Journal of Power System Engineering
    • /
    • 제20권2호
    • /
    • pp.51-57
    • /
    • 2016
  • Non-esterified biodiesel fuel is cheaper than esterified that because of a simple manufacturing process that only consists of filtering. Applicability of this on diesel engine with electronic control system was accomplished, then optimization adopting a fractional factorial design and response surface methodology was carried out at 25% and 50% of engine load in this study. Pressure of common rail and injection timing mainly effected on responses as specific fuel oil consumption and nitrogen oxides regardless of engine load. Estimations were 310.3 g/kWh of specific fuel oil consumption and 237 ppm of nitrogen oxides at 25% load, and 233.2 g/kWh of specific fuel oil consumption and 730 ppm of nitrogen oxides at 50% load. Tests to verify these estimations were accomplished and as the results, specific fuel oil consumption was 300.4 g/kWh and NOx was 277 ppm at 25% load and 236.8 g/kWh and 573 ppm at 50% load.

Evaluating Changes and Uncertainty of Nitrogen Load from Rice Paddy according to the Climate Change Scenario Multi-Model Ensemble (기후변화시나리오 다중모형 앙상블에 따른 논 질소 유출 부하량 변동 및 불확실성 평가)

  • Choi, Soon-Kun;Jeong, Jaehak;Yeob, So-Jin;Kim, Minwook;Kim, Jin Ho;Kim, Min-Kyeong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제62권5호
    • /
    • pp.47-62
    • /
    • 2020
  • Rice paddy accounts for approximately 52.5% of all farmlands in South Korea, and it is closely related to the water environment. Climate change is expected to affect not only agricultural productivity also the water and the nutrient circulation. Therefore this study was aimed to evaluate changes of nitrogen load from rice paddy considering climate change scenario uncertainty. APEX-Paddy model which reflect rice paddy environment by modifying APEX (Agricultural Policy and Environmental eXtender) model was used. Using the AIMS (APCC Integrated Modeling Solution) offered by the APEC Climate Center, bias correction was conducted for 9 GCMs using non-parametric quantile mapping. Bias corrected climate change scenarios were applied to the APEX-Paddy model. The changes and uncertainty in runoff and nitrogen load were evaluated using multi-model ensemble. Paddy runoff showed a change of 23.1% for RCP4.5 scenario and 45.5% for RCP8.5 scenario compared the 2085s (2071 to 2100) against the base period (1976 to 2005). The nitrogen load was found to be increased as 43.9% for RCP4.5 scenario and 76.0% for RCP8.5 scenario. The uncertainty analysis showed that the annual standard deviation of nitrogen loads increased in the future, and the maximum entropy indicated an increasing tendency. And Duncan's analysis showed significant differences among GCMs as the future progressed. The result of this study seems to be used as a basis for mid- and long-term policies for water resources and water system environment considering climate change.

River Water Quality Impact Assessment in an Intensive Livestock Farming Area During Rainfall Event using Physicochemical characteristics and Nitrogen Stable Isotopes (이화학적 특성과 질소 안정동위원소비를 활용한 강우시 가축사육 밀집 지역의 하천 수질 영향 평가)

  • Ryu, Hong-Duck;Baek, Un-Il;Kim, Sun-Jung;Kim, Deok-Woo;Kim, Chansik;Kim, Min-Seob;Shin, Dongseok;Lee, Jae-Kwan;Chung, Eu Gene
    • Journal of Environmental Science International
    • /
    • 제28권1호
    • /
    • pp.7-18
    • /
    • 2019
  • This study aimed to assess the impact of livestock excreta discharged from an Intensive Livestock Farming Area (ILFA) on river water quality during a rainfall event. The Bangcho River, which is one of the 7 tributaries in the Cheongmi River watershed, was the study site. The Cheongmi River watershed is the second largest area for livestock excreta discharge in Korea. Our results clearly showed that, during the rainfall event, the water quality of the Bangcho River was severely deteriorated due to the COD, $NH_4-N$, T-N, $PO_4-P$, T-P, and heavy metals (Cu, Zn, and Mn) in the run-off from nearby farmlands, where the soil comprised composted manure and unmanaged livestock excreta. In addition, stable isotope analysis revealed that most of nitrogen ($NH_4-N$ and $NO_3-N$) in the run-off was from the ammonium and nitrate in the livestock excreta. The values of ${\delta}^{15}N_{NH4}$ and ${\delta}^{15}N_{NO3}$ for the Bangcho River water sample, which was obtained from the downstream of mixing zone for run-off water, were lower than those for the run-off water. This indicates that there were other nitrogen sources upstream river in the river. It was assumed from ${\delta}^{15}N_{NH4}$ and ${\delta}^{15}N_{NO3}$ stable isotope analyses that these other nitrogen sources were naturally occurring soil nitrogen, nitrogen from chemical fertilizers, sewage, and livestock excreta. Therefore, the use of physicochemical characteristics and nitrogen stable isotopes in the water quality impact assessment enabled more effective analysis of nitrogen pollution from an ILFA during rainfall events.

The Effects of Changing of Hydraulic Retention Time and Charging Media on the Removal of Nitrogen and Phosphorus in the Up-flow Anaerobic/Anoxic Reactor and Water-mill for Sewage Treatment (상향류식 혐기성조, 무산소조 및 수차호기조를 이용한 하수처리시 수리학적 체류시간의 변화와 메디아 충진이 질소 및 인 제거에 미치는 영향)

  • Shin, Myoung-Chul;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • 제35권1호
    • /
    • pp.64-70
    • /
    • 2009
  • The aims of this study is to examine the effects of the changes in HRT(Hydraulic Retention Time) and media charge in a water-mill, among other operation factors, on the nitrogen and phosphorus removal in order to use up-flow anaerobic reactors, anoxic reactors and water-mill aerobic reactors for sewage treatment. The extension of HRT improved the nitrogen removal efficiency, however the removal pattern was constant regardless of HRT. The removal of phosphorus was constant (80%-90%) regardless of the change in HRT. The removal rate with change in influx load varied such that at the OLR (Organic Load Rate) of 1-3 kg/d, the T-N removal efficiency was 80.7%-88.9% and the T-P removal efficiency was 82.9%-89.3% while at the NLR (Nitrogen Loading Rate) of 0.108-0.156 kg/d the removal efficiencies were 80.7-88.9% (T-N) and 82.9-89.3% (T-P). The analyses of the nitrogen and phosphorous removal characteristics with the C/N and C/P ratio showed that the mean T-N removal rate was 88% at the C/N ratio of 1.2-2.6, and that the mean T-P removal rate was 86% at the C/P ratio of 7.2-14.1. Also, the analysis of nitrogen and phosphorous removal characteristics were analyzed in relation to media charge. The comparison between with and without media charge in the water-mill showed that while the nitrogen removal efficiencies were 86-94% and 85-89% respectively, the difference of phosphorous removal efficiencies were between the two conditions was not significant, thus it suggested that the media charge has less effect on the removal efficiency of phosphorous compared to that of nitrogen.

Comparison of Exhaust Gas Recirculation and Excess Air Strategies for Improving Thermal Efficiency and Reducing Nitrogen Oxides emissions in Hydrogen Spark-ignition Engines at Low-load Operation (수소 스파크점화 엔진의 저부하 운전에서 열효율 및 질소산화물 배출 개선을 위한 배기가스재순환과 과잉공기 전략 비교)

  • Hyunwook Park;Junsun Lee;Seungmook Oh;Yonggyu Lee;Changup Kim
    • Journal of ILASS-Korea
    • /
    • 제29권2호
    • /
    • pp.60-67
    • /
    • 2024
  • This study compared exhaust gas recirculation (EGR) and excess air strategies for improving thermal efficiency and emissions of hydrogen combustion engines at low-load operation. The experimental investigation was conducted in a single-cylinder, heavy-duty engine under throttling and wide-open throttle (WOT) conditions. Although both EGR and excess air strategies reduced peak heat release rates and increased combustion durations, the net indicated thermal efficiencies were improved by reducing the pumping losses. Under the constraint of similar nitrogen oxides emissions, the EGR strategy had higher net indicated thermal efficiencies compared to the excess air strategy in throttling operation. However, the difference between their thermal efficiencies was reduced under WOT condition. The trend of reducing nitrogen oxides emissions according to the two strategies was similar.

Correlation between operation factors and nitritation using anaerobic digester supernatant at ordinary temperature (상온 조건에서 혐기 소화 상징액을 이용한 아질산화 반응과 운전 인자의 상관성 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • 제18권3호
    • /
    • pp.244-249
    • /
    • 2016
  • Anaerobic digester supernatant including high concentrations of nitrogen is recycled to water treatment line and make pollutant load increase in municipal wastewater treatment plant(MWTP). To treat nitrogen in anaerobic digester supernatant is suggested the method of MWTP retrofit. In this study, the lab scale reactor was operated about 200 days using supernatant of anaerobic digester. The results could draw operation condition that ammonium nitrogen removal efficiency more than 90% and nitrite conversion efficiency over 70%. Correlation between operation efficiency and operation factors was analyzed based on the operation results. Ammonium nitrogen remove efficiency and nitrite conversion efficiency were related to solid retention time (SRT), ammonium nitrogen load and ammonium nitrogen loading per unit mixed liquer suspended solid (MLSS). Results of this study can be used effective data on nitritation of supernatant of anaerobic digester, and be expected to increase availability of nitritation.

Design of Termination Cryostat for HTS Power Cable (고온초전도 케이블 단말용 cryostat 설계)

  • 양형석;김승현;김동락;조승연;김도형;류희석;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.160-162
    • /
    • 2003
  • Termination cryostat for 22.9kV, 1.26kA-class HTS power cable has been designed. The cryostat consists of vacuum vessel, liquid nitrogen vessel, current lead and HTS power cable. The current lead and the HTS power cable are connected in liquid nitrogen vessel cooled by forced-circulation subcooled liquid nitrogen. The maximum total heat load of this cryostat is expected to be 150w. In this paper, the detailed design of the termination cryostat is mentioned.

  • PDF

A Study on Tensile Strength of the 3D Printing Product According to the Nitrogen Concentration of Chamber Inside (챔버 내부의 질소 농도에 따른 3D프린팅 출력물의 인장 강도에 관한 연구)

  • Lee, Song Yeon;Huh, Yong Jeong
    • Journal of the Semiconductor & Display Technology
    • /
    • 제21권1호
    • /
    • pp.103-107
    • /
    • 2022
  • Scaffolds are the structures that safely protect sensors in various parts of the body. Because of scaffolds must protect sensors from load, the tensile strength of the scaffolds must be higher than 750 kgf/cm2. Currently, the tensile strength of scaffolds made with the 3d printer is 714 kgf/cm2. We confirm that the tensile strength of the scaffolds increase using air with high nitrogen concentration. In this study, we conducted experiments to find nitrogen concentrations in which the tensile strength of the specimen is higher than 750 kgf/cm2. The nitrogen control device and the nitrogen concentration sensor were installed in the chamber type 3d printer. The nitrogen concentration inside the 3d printer was changed by 5 % from 80 % to 100 %. Specimens of ASTM D 638 standard were produced under changed nitrogen concentration. We measured the tensile strength of specimens. We compared the tensile strength of specimens produced under each nitrogen concentration. We confirmed that when air with nitrogen concentration of 90 % was used, the tensile strength of scaffolds were 762 kgf/cm2.

Evaluation of Phosphorus and Nitrogen Delivery Characteristics of Chogang Stream Sediments (초강천의 퇴적물 분석을 이용한 총인 및 질소의 유달 특성 평가)

  • Kang, Seon-Hong;Seo, Dong-il
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제11권4호
    • /
    • pp.99-109
    • /
    • 1997
  • To estimate the nutrients delivery characteristics of Chogang stream to Keum River, sediment and soil characteristics were analyzed in the stream and in the stream bank. Along the stream, soil samples from river sediment were collected and tested monthly for phosphorus and nitrogen concentrations. Nitrogen concentration in the sediment is much lower than that of soil in the river bank especially in summer presumably due to the high desorption characteristics of nitrogen by the increasing rainfall energy during summer. Instead, the concentrations of phosphorus were similar for the sediment and the soil in the river bank due to the strong adsorption characteristics of phosphorus. Batch tests were performed to evaluate the desorption potential of the sediments. Universal Soil Loss Equation (USLE) was applied to quantify soil erosion in each watershed due to rainfall. It was estimated that approximately 25% of total phosphorus by mass basis could be released from the sediment if the water was disturbed vigorously. The mass load of nitrogen and phosphorus into the Chogang Stream from the watershed were evaluated from the USLE and release ratio of phosphorus.

  • PDF