• Title/Summary/Keyword: Nitrate ion

Search Result 337, Processing Time 0.03 seconds

Groundwater and Soil Environment of Plastic Film House Fields around Middle Korea (우리나라 중부지방 시설원예지 토양 및 지하수 환경)

  • Kim, Jin-Ho;Ryu, Jong-Soo;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.479-483
    • /
    • 2001
  • This Study was carried out to know the soil properties and the quality of shallow groundwater in the plastic film house fields around mid-Korea. This study was conducted at 11 sites in Suweon, Pyungtaek, Yongin, and Chunchen on May, June, July and August in 1999. The the average concentration of nitrate-nitrogen was 19.1 mg/L, it reached almost to the limiting level, 20 mg/L. Moreover about 36.4% of survey sites exceeded limiting level to agricultural groundwater quality. And Sulfur concentrations also at some sites exceeded to agricultural groundwater quality limit level (50 mg/L), which could make damage to the crop. Nitrate-nitrogen, which is one of the most important factors in the groundwater quality, It has highly positive correlation with any other ion in groundwater. This result showed that groundwater quality management practices should be taken for the agricultural production as well as for environment at the plastic film house areas.

  • PDF

Characterization of Size distribution of Anion Species in Atmospheric Aerosols (대기에어로졸중 음이온성분에 대한 입경분포의 변화특성)

  • 최금찬;박정호;임경택
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.124-129
    • /
    • 1994
  • Aerosol size distribution was determined using Anderson sampler for the anions( sulfate nitrate and chloride ) and TSP. Ionic species concentration and size distribution have been investigated in the daytime and nightime individually. Size classified samples were extracted with distilled water and analyzed for C $l^{[-10]}$ , N $O_3$$^{[-10]}$ and S $O_4$$^{2-}$, by ion chromatography. The size distribution of these ions and TSP was analyzed to investigate the seasonal and diurnal variation of concentrations as follows: (1)Size distribution of TSP showed bi- modal type in the daytime, but indicated tri-mode distribution in the nightime without any seasonal variation. (2)Sulfate concentrations were higher in fine- mode both in the daytime and nightime but fraction of sulfate was higher in coarse-mode during the Yellow Sand Period. (3)Nitrate and Chloride ions are dominant in fine-mode in winter while dominant in coarse-mode in the summer.

  • PDF

Evaluation of Denitrification Efficiency and Functional Gene Change According to Carbon(Fumarate) Concentration and Addition of Nitrate Contaminated-soil in Batch System (회분식반응조 실험을 통한 탄소원(Fumarate) 주입조건에 따른 지하수 중 탈질율 및 탈질 관련 기능성 유전자 분석)

  • Park, Sunhwa;Kim, Hyun-Koo;Kim, Moon-su;Lee, Gyeong-Mi;Jeon, Sang-Ho;Song, Dahee;Kim, Deok-hyun;Kim, Young;Kim, Tae-seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.7
    • /
    • pp.80-89
    • /
    • 2015
  • Nitrate is on the most seriou pollutant encountered in shallow groundwater aquifer in agricultural area. There are various remediation technologies such as ion exchange, reverse osmosis, and biological denitrification to recover from nitrate contamination. Biological denitrification by indigenous microorganism of the technologies has been reviewed and applied on nitrate contaminated groundwater. In this work, we selected the site where the annual nitrate (NO3) concentration is over 105 mg/L and evaluated denitrification process with sampled soil and groundwater from 3 monitoring wells (MW4, 5, 6). In the results, the nitrate degradation rate in each well (MW 4, 5, and 6) was 25 NO3 mg/L/day, 6 NO3 mg/L/day, and 3.4 NO3 mg/L/day, respectively. Nitrate degradation rate was higher in batch system treated with 2 times higher fumarate as carbon source than control batch system (0.42M fumrate/1M NO3), comparing with batch system with soil sample. This result indicates that increase of carbon source is more efficient to enhance denitrification rate than addition of soil sample to increase microbial dynamics. In this work, we also confirmed that monitoring method of functional genes (nirK and nosZ) involved in denitrification process can be applied to evaluated denitrifcation process possibility before application of field process such as in-situ denitrification by push-pull test.

Continuous Measurement of Ammonium-nitrogen and Nitrate-nitrogen using a Ion-Selective Microelectrode (이온선택성 미소전극을 이용한 암모니아성 질소 및 질산성 질소의 연속 농도 측정)

  • Lim, Mi-Ji;Seon, Ji-Yun;Park, Jeung-Jin;Byun, Im-Gyu;Park, Tae-Joo;Lee, Tae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.718-724
    • /
    • 2008
  • The ion selective microelectrode (ISME) has been used for measuring the ion profile of DO, $NH_4{^+}-N$, $NO_2{^-}-N$ and $NO_3{^-}-N$ in biofilm. In this study we evaluated the detection limit and validity of ISME and applied ISME for the continuous measurement of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration in the modified Ludzack-Ettinger (MLE) process. Average detection limits of $NH_4{^+}-N$ and $NO_3{^-}-N$ ISME were $10^{-4.44}M$ and $10^{-4.62}M$, respectively. Since the ISME with $5{\sim}10{\mu}m$ of tip diameter showed a faster response time than that of $1{\sim}5{\mu}m$, the ISME with a tip diameter of $5{\sim}10{\mu}m$ was fabricated and used to make real-time ion detections. Direct monitoring of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentrations in the aerobic (2) tank causes the instability of the electromotive force (EMF) for the initial 5~8 hours and also causes remarkable error values of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration. This phenomenon is caused by aeration and mixing in the reactor. Thus, the measuring chamber was newly designed for the aerobic (2) tank and then the EMF of the ISME were stabilized in less than 1 hour. Errors of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration were decreased after stabilization of the EMF. The ISME analysis were well corresponded to the results of auto analyzer and ion chromatography. Consequently, the concentration of $NH_4{^+}-N$ and $NO_3{^-}-N$ could be continuously measured for 178 hours by the ISME.

Correlations between the ions in the precipitation at Chongwon, Chungbuk (충북 청원군의 강수중의 이온들간의 상관관계)

  • 박용남;송기형
    • Journal of Environmental Science International
    • /
    • v.2 no.4
    • /
    • pp.337-346
    • /
    • 1993
  • The amount of inorganic ions such as $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$, $NH_4^+$, $Cl^-$, $NO_3^-$, and $SO_4^{2-}$ in the precipitation at hongwon area were analyzed during the period of February 1991 - June 1993. Ammonium ion was analyzed using Messier and indophenol methods. Cations were determined by atomic absorption spectroscopy, and ion chromatography was used for anions. For the entire period of study, there was no particular ion which has significant]y high correlation coefficient with hydrogen ion. The correlation between $NO_3^-$, and $SO_4^{2-}$ was 0.6, which suggests that these ions may be from the same source. Most cations have high correlation with each other. In the seasonal analysis, the nitrate and sulfate ions have high correlations with the acidity in the fall and winter. The rain waters of Taeahn area showed usually high concentrations of the ions, even though the pH was much higher than that of Chongwon area. It is considered that the ions came as neutral salt in Taeahn, while $NO_x$ and $SO_x$ contributes largely to the acidity of rains in Chongwon.

  • PDF

Reaction Characteristics of 4-Methylcatechol 2,3-Dioxygenase from Pseudomonas putida SU10

  • Ha, You-Mee;Jung, Young-Hee;Kwon, Dae-Young;Kim, Young-Soo;Kim, Chy-Kyung;Min, Kyung-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2000
  • Reaction characteristics of 4-methylcatechol 2,3-dioxygenase (4MC230) purified from Pseudomonas putida SU10 with a higher activity toward 4-methylcatechol than catechol or 3-cethylcatechol were studied by altering their physical and chemical properties. The enzyme exhibited a maximum activity at pH 7.5 and approximately 40% at pH 6.0 for 4-methylcatechol hydrolysis. The optimum temperature for the enzyme was around $35^{\circ}C$, since the enzyme was unstable at higher temperature. Acetone(10%) stabilized the 4MC230. The effects of solvent and other chemicals (inactivator or reactivator) for the reactivation of the 4MC230 were also investigated. Silver nitrate and hydrogen peroxid severely deactivated the enzyme and the deactivation by hydrogen peroxide severely deactivated the enzyme and the deactivation by hydrogen peroxide was mainly due to the oxidation of ferrous ion to ferric ion. Some solvents acted as an activator and protector for the enzyme from deactivation by hydrogen peroxide. Ascorbate, cysteine, or ferrous ion reactivated the deactivated enzyme by hydrogen peroxide. The addition of ferrous ion together with a reducing agent fully recovered the enzyme activity and increased its activity abut 2 times.

  • PDF

Characteristics According to the Size Distributions of Respirable Particulate During Yellow Sand Episode in Kosan, Jeju Island (황사기간도안 제주, 고산지역에서 호흡성 분진의 입자 분포 특성)

  • Kim, Jeong-Ho;Ahn, Jun-Young;Han, Jin-Seok;Lee, Jeong-Joo
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.3
    • /
    • pp.91-96
    • /
    • 2003
  • This study was intended as an investigation of characteristics of background site atmospheric respirable particulate matters(RPM), and fine particles(<2.5 ${\mu}{\textrm}{m}$). The particle size distributions during the phenomenon of Yellow Sand(YS) occurs from April, 2001. Atmospheric aerosol particulate matter was directly collected on the Jeju island between 1 to 30, April, 2001 using an eight-stage cascade impacter(particle size range: 0.43-11 ${\mu}{\textrm}{m}$), and cyclone separator(cut size: 2.5, 10 ${\mu}{\textrm}{m}$). The episode of YS observed in background monitoring site, Kosan and appeared 2 times at sampling period. The mass concentrations of fine and coarse particles for YS episode were 34.2 and 59.6 $\mu\textrm{g}$/㎥, respectively, which were significantly increased amounts compared to 13.3 and 13.0 $\mu\textrm{g}$/㎥ for NonYS(NYS). Most size distributions had two peaks, one at 0.43∼.65 ${\mu}{\textrm}{m}$ and the other at 3.3${\mu}{\textrm}{m}$4.7 ${\mu}{\textrm}{m}$. The result of analysis of water-soluble ion component indicated that sulfate was mainly ion component, but nitrate and calcium ion was significantly increased at the YS episode.

Applicability of Colormetric Method for Estimation of Chloride Penetration in Concrete Structures (콘크리트 구조물의 염화물 침투 특성 파악을 위한 변색법의 적용성)

  • Yang Eun-Ik;Kim Myung-Yu;Leem Young-Moon;Park Hae-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.931-938
    • /
    • 2005
  • When concrete structures are exposed under marine condition for a long time, the steel in concrete is corroded due to the ingression of chlorides in the seawater. Because the damages of corrosion resulting from the chloride ion are very serious, many researches have been performed. Silver nitrate colormetric method that can measure easily penetration depth of chloride ion has been executed, recent)y. However, characteristics of silver nitrate colormetric method were not fully examined. Therefore, the objective of this paper Is to study the applicability of colormetric method. For the purpose of this, effect factors and reaction mechanism of colormetric method were investigated, and the colormetric method is applied for marine concrete structures. According to the results of silver nitrate colored method, two reactions such as white reaction of AgCl and brown reaction of AgOH were shown when $AgNO_3$ was sprayed in splited section. And velocity constant ratio(K) of two reactions appeared that white reaction, AgCl reacts with the fast speed by 3240. When the colormetric method was applied in concrete, it is reasonable that $AgNO_3$ solution more than 0.05N concentration was sprayed. It is confirmed that the colormetric method is useful tool for estimating the chloride of concrete structures in situ. The average chloride amount of colored parts indicates $0.9kg/m^3$ per concrete unit weight.

Effects of Salt in Soil Condition on Chlorophyll Fluorescence and Physiological Disorder in Panax ginseng C. A. Meyer (토양 염류 농도가 인삼 잎의 엽록소 형광반응 및 생리장해 발생에 미치는 영향)

  • Kim, Jang Uk;Hyun, Dong Yun;Kim, Young Chang;Lee, Jung Woo;Jo, Ick Hyun;Kim, Dong Hwi;Kim, Kee Hong;Sohn, Jae Keun
    • Korean Journal of Medicinal Crop Science
    • /
    • v.23 no.6
    • /
    • pp.446-453
    • /
    • 2015
  • Background : Excessively high concentration of sodium ion causednutrient deficiency and significantly decrease growth. This study was carried out to determine the limiting concentration range of sodium ion in the soil of ginseng field. Methods and Results : The growth of the ginseng cultivar Chunpoong reduced with increase in salinity, and the rate of growth reduction was higher in shoots than that of roots. Particularly, ginseng plants cultivated at high level of nitrate nitrogen or sodium may suffer delayed development and stunted growth. Chlorophyll damage occurred on the leaves of ginseng planted in relatively high levels (> $0.2cmol^+/kg$) of sodium ion, as determined by the fluorescence reaction. The incidence of physiological disorder in ginseng cultivated at 249 sites was correlated with the concentration of sodium ion in the soils. About 74% of ginseng fields in which physiological disorders occurred had concentrations of sodium ion in soil greater than $0.2cmol^+/kg$. In contrast, the concentration of sodium ions at 51 of 85 sites where no damage occurred was relatively ($0.05cmol^+/kg-0.15cmol^+/kg$). Conclusions : The concentration of sodium ion in soil of ginseng fields can be classified into three levels optimum (${\leq}0.15$), permissible allowance (0.15 - 0.2) and excessive (> 0.2).

Studies on the Synthesis of Aminated PP-g-GMA Fibrous ion Exchanger by E-beam Pre-irradiation and Their Properties of Selective Adsorption for $NO_{3} ^{-}$ (E-beam 전조사에 의한 $NO_{3} ^{-}$ 선택 흡착용 아민화 PP-g-GMA 섬유 이온교환체의 합성과 그 특성에 관한 연구)

  • 황택성;이선아;이면주
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.153-159
    • /
    • 2002
  • In order to remove $NO_3;^-$ ion from ground-water, fibrous ion -exchangers, APP-g-GMA, were synthesized by GMA grafting onto PP trunk polymer with E-beam accelerator for pre-irradiation. Their degrees of grafting and amination yield increased up to $60^{\circ}C$ and showed maximum values as 133%, 88%, respectively. And their swelling ratio and ion exchange capacity at the maximum values are 86%, 2.5 meq/g, respectively which was higher than commercial ion-exchangers such as IMAC HP555 and Amberlite IRA 400. Optimum adsorption condition of $NO_3;^-$ ion was measured at pH 5~6 and -Cl form of APP-g-GMA containing trimethylammonium group showed the highest adsorption capacity.