• Title/Summary/Keyword: Nipple-areolar sparing mastectomy

Search Result 19, Processing Time 0.02 seconds

Usefulness of the Purse-string Suture Technique for Aesthetic Breast Reconstruction Surrounding the Nipple-areolar Complex (유두 유륜 복합체 주변의 미용적 유방 재건을 위한 주머니끈 봉합의 유용성)

  • Song, Jung-Yoon;Jin, Ung-Sik;Chang, Hak;Minn, Kyung-Won
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.715-717
    • /
    • 2011
  • Purpose: In cases of breast reconstruction with a free transverse rectus abdominis musculocutaneous (TRAM) flap after skin-sparing mastectomy with nipple-areolar complex (NAC) removal, the flat contour of the flap's skin paddle can easily look unnatural and dissatisfying. Reconstructed NAC on the flap surface lacks the elevated contour that the normal areola possesses, resulting in an unnatural final result. Therefore, we would like to introduce a novel method to improve this problem and report the satisfactory results we obtained. Methods: Operations were conducted on 19 patients who underwent immediate breast reconstruction with a free TRAM flap and skin-sparing mastectomy from January 2009 to January 2010, with a mean follow-up of nine months. While the TRAM free flap was being inset, a purse-string suture was carried out on the dermal layer of skin flap to create a slight protrusion with Gore-$Tex^{(R)}$ sutures. Results: The elevated mound surrounding the NAC was well maintained for an average follow-up period of nine months. Nipple projection was also well maintained. There was no complaint about breast contour or nipple height reduction. In addition, there was no reported incidence of other complications. Conclusion: The purse-string suture technique presents a more natural breast silhouette around the NAC and helps to maintain nipple projection. Furthermore, it does not require any supplementary incisions or complicated skills. There has been no report of additional complications using this technique.

One-Stage Nipple and Breast Reconstruction Following Areola-Sparing Mastectomy

  • Kim, Hye Ri;Lim, Jin Soo;Kim, Sue Min;Jung, Sung No;Yoo, Gyeol;Rha, Eun Young
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.553-558
    • /
    • 2013
  • Background Skin-sparing mastectomy with immediate breast reconstruction is increasingly becoming a proven surgical option for early-stage breast cancer patients. Areola-sparing mastectomy (ASM) has also recently become a popular procedure. The purpose of this article is to investigate the reconstructive and aesthetic issues experienced with one-stage nipple and breast reconstruction using ASM. Methods Among the patients who underwent mastectomy between March 2008 and March 2010, 5 women with a low probability of nipple-areolar complex malignant involvement underwent ASM and immediate breast reconstruction with simultaneous nipple reconstruction using the modified C-V flap. The cosmetic outcomes of this series were reviewed by plastic surgeons and patient self-assessment and satisfaction were assessed via telephone interview. Results During the average 11-month follow-up period, there were no cases of cancer recurrence, the aesthetic outcomes were graded as excellent to very good, and all of the patients were satisfied. Two patients developed a gutter-like depression around the reconstructed nipple, and one patient developed skin erosion in a small area of the areola, which healed with conservative dressing. The other complications, such as necrosis of the skin flap or areola, seroma, hematoma, or fat necrosis did not occur. Conclusions Since one-stage nipple and breast reconstruction following ASM is an oncologically safe, cost-effective, and aesthetically satisfactory procedure, it is a good surgical option for early breast cancer patients.

Use of Magnetic Resonance Imaging for Evaluating Residual Breast Tissue After Robotic-Assisted Nipple-Sparing Mastectomy in Women With Early Breast Cancer

  • Wen-Pei Wu;Hung-Wen Lai;Chiung-Ying Liao;Joseph Lin;Hsin-I Huang;Shou-Tung Chen;Chen-Te Chou;Dar-Ren Chen
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.640-646
    • /
    • 2023
  • Objective: Prospective studies on postoperative residual breast tissue (RBT) after robotic-assisted nipple-sparing mastectomy (R-NSM) for breast cancer are limited. RBT presents an unknown risk of local recurrence or the development of new cancer after curative or risk-reducing mastectomies. This study investigated the technical feasibility of using magnetic resonance imaging (MRI) to evaluate RBT after R-NSM in women with breast cancer. Materials and Methods: In this prospective pilot study, 105 patients, who underwent R-NSM for breast cancer at Changhua Christian Hospital between March 2017 and May 2022, were subjected to postoperative breast MRI to evaluate the presence and location of RBT. The postoperative MRI scans of 43 patients (age, 47.8 ± 8.5 years), with existing preoperative MRI scans, were evaluated for the presence and location of RBT. In total, 54 R-NSM procedures were performed. In parallel, we reviewed the literature on RBT after nipple-sparing mastectomy, considering its prevalence. Results: RBT was detected in 7 (13.0%) of the 54 mastectomies (6 of the 48 therapeutic mastectomies and 1 of the 6 prophylactic mastectomies). The most common location for RBT was behind the nipple-areolar complex (5 of 7 [71.4%]). Another RBT was found in the upper inner quadrant (2 of 7 [28.6%]). Among the six patients who underwent RBT after therapeutic mastectomies, one patient developed a local recurrence of the skin flap. The other five patients with RBT after therapeutic mastectomies remained disease-free. Conclusion: R-NSM, a surgical innovation, does not seem to increase the prevalence of RBT, and breast MRI showed feasibility as a noninvasive imaging tool for evaluating the presence and location of RBT.

Immediate Implant Reconstruction using Silicone Prosthesis in Breast Cancer Patients after Skin Sparing Mastectomy (유방암 환자에서 피부보존 유방절제술 후 실리콘 보형물을 이용한 즉시 유방재건술)

  • Cho, Young-Kyoo;Yang, Jung-Dug;Kim, Gui-Rak;Chung, Ho-Yun;Cho, Byung-Chae;Park, Ho-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.749-757
    • /
    • 2010
  • Purpose: Since skin sparing mastectomy removes the mammary gland and the nipple-areolar complex preserving all mammary skin, it makes the widespread use of implants in immediate reconstruction. This article reports our experience in immediate breast reconstruction after skin sparing mastectomy by using the silicone implants in patients especially who have small to moderate sized and minimal ptotic breast. Methods: From September of 2007 to July of 2009, we performed breast reconstruction for 44 breasts of 40 women with silicone implant after mastectomy. Tumors were divided into 5 malignant types (21 IDC, 18 DCIS, 2 ILC, 2 phylloides tumor, 1 mucinous carcinoma). The implant is placed in a submuscular pocket or in a submuscularsubfascial pocket depending upon the condition of the muscles and skin flaps after mastectomy. Results: The mean age was 47 years and the average follow-up period was 11 months. Cosmetic outcome was assessed by evaluation of photographs and assessment of breast volume and shape, breast symmetry, and overall outcome. About 80% of each of these parameters was scored as good or excellent. Breast complication was developed in a total of 6 cases including 2 capsular contracture, 2 partial skin necrosis due to blue dye injection and 2 implant infection. Conclusion: The use of definitive implants in a skin sparing mastectomy is a one-stage immediate breast reconstruction with low morbidity and acceptable result. This method is considered reliable with favorable aesthetic result.

Immediate breast reconstruction following nipple-sparing mastectomy in an Asian population: Aesthetic outcomes and mitigating nipple-areolar complex necrosis

  • Pek, Wan-Sze;Tan, Bien-Keem;Ng, Yvonne Ying Ru;Tan, Veronique Kiak Mien;Rasheed, Mohamed Zulfikar;Tan, Benita Kiat Tee;Ong, Kong Wee;Ong, Yee Siang
    • Archives of Plastic Surgery
    • /
    • v.45 no.3
    • /
    • pp.229-238
    • /
    • 2018
  • Background Nipple-sparing mastectomies (NSMs) are increasingly performed to obtain the best aesthetic and psychological outcomes in breast cancer treatment. However, merely preserving the nipple-areolar complex (NAC) does not guarantee a good outcome. Darkly pigmented NACs and a tendency for poor scarring outcomes are particular challenges when treating Asian patients. Herein, we review the reconstructive outcomes following NSM at Singapore General Hospital. Methods All breasts reconstructed following NSM over an 11-year period from 2005 to 2015 were reviewed. Information was collected from the patients' records on mastectomy indications, operative details, and complications. Patient satisfaction, breast sensation, and aesthetic outcomes were evaluated in 15 patients. Sensation was quantified using the Semmes-Weinstein monofilament test. Results A total of 142 NSMs were performed in 133 patients for breast cancer (n=122, 85.9%) or risk reduction (n=20, 14.1%). Of the procedures, 114 (80.2%) were autologous reconstructions, while 27 (19.0%) were reconstructions with implants. Complications occurred in 28 breasts (19.7%), with the most common complication being NAC necrosis, which occurred in 17 breasts (12.0%). Four breasts (2.8%) had total NAC necrosis. The overall mean patient satisfaction score was 3.0 (good). The sensation scores were significantly diminished in the skin envelope, areola, and nipple of breasts that had undergone NSM compared to non-operated breasts (P<0.05). Half of the subset of 15 patients in whom aesthetic outcomes were evaluated had reduced nipple projection. Conclusions Immediate reconstruction after NSM was performed with a low complication rate in this series, predominantly through autologous reconstruction. Patients should be informed of potential drawbacks, including NAC necrosis, reduced nipple projection, and diminished sensation.

Direct-to-implant breast reconstruction following nipple-sparing mastectomy: predictive factors of adverse surgical outcomes in Asian patients

  • Su, Chun-Lin;Yang, Jia-Ruei;Kuo, Wen-Ling;Chen, Shin-Cheh;Cheong, David Chon-Fok;Huang, Jung-Ju
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.483-493
    • /
    • 2021
  • Background Direct-to-implant (DTI) breast reconstruction after nipple-sparing mastectomy (NSM) with the use of acellular dermal matrix (ADM) provides reliable outcomes; however, the use of ADM is associated with a higher risk of complications. We analyzed our experiences of post-NSM DTI without ADM and identified the predictive factors of adverse surgical outcomes. Methods Patients who underwent NSM and immediate DTI or two-stage tissue expander (TE) breast reconstruction from 2009 to 2020 were enrolled. Predictors of adverse endpoints were analyzed. Results There were 100 DTI and 29 TE reconstructions. The TE group had a higher rate of postmastectomy radiotherapy (31% vs. 11%; P=0.009), larger specimens (317.37±176.42 g vs. 272.08±126.33 g; P=0.047), larger implants (360.84±85.19 g vs. 298.83±81.13 g; P=0.004) and a higher implant/TE exposure ratio (10.3% vs. 1%; P=0.035). In DTI reconstruction, age over 50 years (odds ratio [OR], 5.43; 95% confidence interval [CI], 1.50-19.74; P=0.010) and a larger mastectomy weight (OR, 1.65; 95% CI, 1.08-2.51; P=0.021) were associated with a higher risk of acute complications. Intraoperative radiotherapy for the nipple-areolar complex increased the risk of acute complications (OR, 4.05; 95% CI, 1.07-15.27; P=0.039) and the likelihood of revision surgery (OR, 5.57; 95% CI, 1.25-24.93; P=0.025). Conclusions Immediate DTI breast reconstruction following NSM is feasible in Asian patients with smaller breasts.

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis

  • Jung Hee Byon;Seungyong Hwang;Hyemi Choi;Eun Jung Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.739-751
    • /
    • 2023
  • Objective: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer. Materials and Methods: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values. Results: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%. Conclusion: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.

Mondor's Disease after Immediate Breast Reconstruction with Silicone Implant (실리콘 보형물을 이용한 즉시 유방재건 후 발생한 Mondor's Disease 치험례)

  • Sun, Sang-Hoon;Lee, Taik-Jong
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.87-90
    • /
    • 2010
  • Purpose: Mondor's disease is commonly known as a benign breast condition after augmentation mammaplasty, and some authors have also reported its association with other breast surgeries such as reduction mammaplasty or axillary lymph node biopsy. Here we report two cases of Mondor's disease after immediate breast reconstruction with silicone implant. Methods: Two women, 51-year-old and 36-year-old, underwent immediate breast reconstruction with silicone implants after nipple-areolar skin-sparing mastectomy. Results: Subcutaneous cord-like firm lesion appeared on upper abdomen, axillary area following surgery. The lesion was painless and spontaneously subsided with no medications. Conclusion: To our knowledge, this is the first report of Mondor's disease developed after immediate breast reconstruction using silicone implant.

Safety of long-term subcutaneous free flap skin banking after skin-sparing mastectomy

  • Verstappen, Ralph;Djedovic, Gabriel;Morandi, Evi Maria;Heiser, Dietmar;Rieger, Ulrich Michael;Bauer, Thomas
    • Archives of Plastic Surgery
    • /
    • v.45 no.2
    • /
    • pp.146-151
    • /
    • 2018
  • Background A persistent problem in autologous breast reconstruction in skin-sparing mastectomies is skin restoration after skin necrosis or secondary oncological resection. As a solution to facilitate reconstruction, skin banking of free-flap skin has been proposed in cases where the overlying skin envelope must be resected, as this technique spares the patient an additional donor site. Herein, we present the largest series to date in which this method was used. We investigated its safety and the possibility of skin banking for prolonged periods of time. Methods All skin-sparing mastectomies and immediate autologous breast reconstructions from December 2009 until June 2013 at our institution were analysed. Results We identified 31 patients who underwent 33 free flap reconstructions in which skin banking was performed. Our median skin banking period was 7 days, with a maximum duration of 171 days. In 22.5% of cases, the banked skin was used to reconstruct overlying skin defects, and in 9.6% of cases to reconstruct the nipple-areolar complex. Microbiological and histological investigations of the banked skin revealed neither clinical infections nor malignancies. Conclusions In situ skin banking, even for prolonged periods of time, is a safe and cost-effective method to ensure that skin defects due to necrosis or secondary oncological resection can be easily reconstructed.