• Title/Summary/Keyword: Ni-Ti instruments

Search Result 78, Processing Time 0.02 seconds

Influence of pre-existing surface defects on NiTi rotary instrument failure: A SEM study

  • Shin, Yu-Mi;Kim, Wu-Sung;Kum, Kee-Yeon
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.594-594
    • /
    • 2003
  • I. Objectives The purpose of this study is to determine if propagation of pre-existing manufacturing defects results in brittle fracture of NiTi rotary files by examining the fracture surface of the instrument by SEM, and to compare the fracture time of NiTi rotary files with different flute designs under cyclic loading. II. Materials and Methods This study examined three groups of rotary NiTi instruments (K3, ProFile, Hero). Of each group, 04 taper, size 30 and 06 taper, size 25 were selected.:120 in total. Surface defects were created by simulating the machining process of NiTi rotaries.(omitted)

  • PDF

A survey of experience-based preference of Nickel-Titanium rotary files and incidence of fracture among general dentists

  • Lee, WooCheol;Song, Minju;Kim, Euiseong;Lee, Hyojin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • Objectives: The purpose was to investigate the preference and usage technique of NiTi rotary instruments and to retrieve data on the frequency of re-use and the estimated incidence of file separation in the clinical practice among general dentists. Materials and Methods: A survey was disseminated via e-mail and on-site to 673 general dentists. The correlation between the operator's experience or preferred technique and frequency of re-use or incidence of file fracture was assessed. Results: A total of 348 dentists (51.7%) responded. The most frequently used NiTi instruments was ProFile (39.8%) followed by ProTaper. The most preferred preparation technique was crown-down (44.6%). 54.3% of the respondents re-used NiTi files more than 10 times. There was a significant correlation between experience with NiTi files and the number of re-uses (p = 0.0025). 54.6% of the respondents estimated experiencing file separation less than 5 times per year. The frequency of separation was significantly correlated with the instrumentation technique (p = 0.0003). Conclusions: A large number of general dentists in Korea prefer to re-use NiTi rotary files. As their experience with NiTi files increased, the number of re-uses increased, while the frequency of breakage decreased. Operators who adopt the hybrid technique showed less tendency of separation even with the increased number of re-use.

TRANSPORTATION OF CURVED CANAL AFTER CANAL ENLARGEMENT ACCORDING TO FILING INSTRUMENTS (만곡근관의 확대시 기구에 따른 형태변화에 관한 연구)

  • Lee, Seok-Jong;Shin, Young-Guen;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.503-510
    • /
    • 1999
  • The purpose of this study was to evaluate the amount of transportation of original canal, zip formation, permanent deformation and fracture of instruments after canal enlargement. In this study, the 60 resin blocks that have curved canals were randomly divided into 3 experimental groups with 20 teeth each according to instrument types and filling methods for canal enlargement. The curved canals of each experimental groups were enlarged to No 40 ISO size with the K-flexo stainless steel file (Group 1), Engine-driven Ni-Ti Profile new series(Group 2) and Engine-driven Ni-Ti Quantec 2000 series(Group 3) according to the manufacturer's recommendation. Pre- and postoperative X-rays were taken at same position and the films were scanned and the canal images were traced to determine the canal curvature according to the method of Schneider. The amount of reduction in canal curvature were calculated between pre- and postoperative X-rays. In addition to zip formation, permanent deformation and fracture of instruments were examined after canal enlargement. The results were as follows : 1. All experimental groups showed some loss of canal curvature after instrumentation. There was a significant change in curvature between before and after instrumentation in each group(p<0.001). 2. Engine-driven Ni-Ti instrumentations resulted in an average loss of curvature of 2.36 degrees for Profile new series, 3.43 degrees for Quantec series, and hand instrumentation showed an average loss of curvature of 6.48 degrees for K-flexo file. There was a statistical significant difference between hand instrumentation and engine-driven Ni-Ti instrumentations(p<0.05). But there was no statistical difference between Profile new series and Quantec series. 3. There were many apical zip formations in group 1(Hand instrumentation). But there were no apical zip formations in group 2,3(Engine-driven Ni-Ti instrumentation). 4. The instrument deformation occured 9 cases in group 1(K-flexo file), 2 cases in group 2(Profile new series) and 3 cases in group 3(Quantec) after instrumentation. And the instrument fracture occured 1 case in each group. The results showed that the engine-driven Ni-Ti instruments, if we use carefully according to manufacturer's recommendations, can be use effectively for instrumenting the curved root canals in case of the MAF was over size 40.

  • PDF

Electrochemical Characteristics of Tooth Colored NiTi Wire (치아색으로 코팅된 NiTi 와이어의 전기화학적 특성)

  • Kim, Won-Gi;Cho, Joo-Young;Choe, Han-Cheol;Lee, Ho-Jong
    • Corrosion Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.223-232
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength, friction resistance, and high corrosion resistance. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate electrochemical characteristics of tooth colored NiTi wire using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with optical microscopy (OM), field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The corrosion properties of the specimens were examined using potentiodynamic tests (potential range of -1500 ~ 2000 mV) and electrochemical impedance spectroscopy (frequency range of 100 kHz ~ 10 mHz) in a 0.9 % NaCl solution by potentiostat. From the results of polarization behavior, the passive region of non-coated NiTi wire showed largely, whereas, the passive region of curved NiTi wire showed shortly in anodic polarization curve. In the case of coated NiTi wire, pitting and crevice corrosion occurred severely at interface between non-coated and coated region. From the results of EIS, polarization resistance(Rp) value of non-coated round and rectangular NiTi wire at curved part showed $5.10{\times}10^5{\Omega}cm^2$ and $4.43{\times}10^5{\Omega}cm^2$. lower than that of coated NiTi wire. $R_p$ of coated round and rectangular NiTi wire at curved part showed $1.31{\times}10^6{\Omega}cm^2$ and $1.19{\times}10^6{\Omega}cm^2$.

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

Surface Characteristics of Polymer Coated NiTi Alloy Wire for Orthodontics (폴리머 코팅된 NiTi합금 교정선의 표면특성)

  • Cho, Joo-Young;Kim, Won-Gi;Choi, Hwan-Suk;Lee, Ho-Jong;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.3
    • /
    • pp.132-141
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate surface characteristics of polymer coated NiTi alloy wire for orthodontics using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with field emission scanning electron microscopy(FE-SEM), energy dispersive x-ray spectroscopy(EDS) and atomic force microscopy(AFM). The phase transformation of non-coated NiTi wire from martensite to austenite occurred at the range of $14{\sim}15^{\circ}C$, in the case of coated wire, it occurred at the range of $16{\sim}18^{\circ}C$. Polymer coating on NiTi wire surface decreased the surface defects such as scratch which was formed at severe machined surface. From the AFM results, the average surface roughness of non-coated and coated NiTi wire was 13.1 nm, and 224.5 nm, respectively. From convetional surface roughness test, the average surface roughness of non-coated and coated NiTi wire was $0.046{\mu}m$, and $0.718{\mu}m$, respectively.

Comparison of mechanical properties of nickel-titanium rotary files: Aurum Blue vs. Aurum Pro (니켈티타늄 전동 파일의 기계적 특성 비교: Aurum Blue vs. Aurum Pro)

  • Kwak, Sang Won;Ha, Jung-Hong;Ahn, Sang Mi;Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.57 no.11
    • /
    • pp.672-678
    • /
    • 2019
  • AIM: The purpose of this study was to evaluate and compare the torsional fracture resistances, cyclic fatigue resistance, and bending stiffness of two nickel-titanium (NiTi) rotary instruments made of different heat-treated alloy: Aurum Blue (heat-treated) and Aurum Pro (conventional). Methods: Forty-five Aurum Blue and Aurum Pro NiTi files were selected for the three mechanical tests (n=15). For the torsional resistance test, 3 mm file tip was fixed and the shaft was driven clockwise at 2 rpm until fracture occurred by using a customized device. Cyclic fatigue resistance was evaluated by rotating instruments in artificial canal with dynamic mode. Bending stiffness was tested by observation of the bending moment on attaining a 45° bend. The results were analyzed by student-t tests at a significance level of 95%. The fractured surface of each groups were examined under a scanning electron microscope (SEM). Results: Aurum Blue showed significantly higher toughness, ultimate strength, distortion angle, and number of cycles to failure than those of Aurum Pro (p < 0.05). However, Aurum Blue and Aurum Pro did not differ significantly in terms of bending stiffness. SEM showed typical topographic appearances of the cyclic fatigue and torsional fracture. Conclusions: Under the limitations of this study, heat-treated instruments showed higher flexibility and fracture resistances than conventional NiTi instruments.

  • PDF

Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments

  • Yilmaz, Koray;Ozyurek, Taha
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.134-139
    • /
    • 2017
  • Objectives: To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature. Materials and Methods: Reciproc R25, WaveOne GOLD Primary, and Tango-Endo instruments were included in this study (n = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and post-hoc Dunn tests were used for the statistical analysis of data in SPSS 21.0 software. Results: Tango-Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life (p < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files (p > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files (p < 0.05). Conclusions: Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.

Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file

  • Shin, D.R.;Park, S.J.;Choi, G.W.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.573.2-573
    • /
    • 2001
  • The objective of this study was to compare the apical shaping ability of the ProFile .04 taper, Lightspeed and HERO 642 rotary instruments and to assess the combined effect of GT Rotary files to Lightspeed and HERO 642 instruments. Forty-eight resin simulated root canal blocks divided into 4 groups with 12 canals. Forty-eight blocks were prepared by one operator with GT Rotary files using a high torque handpiece at 300 rpm. Thirty-six blocks in the three experimental groups were prepared with ProFile 04 taper file, Lightspeed file, HERO 642 file.(omitted)

  • PDF

ROOT CANAL TREATMENT ON PRIMARY TEETH USING NICKEL-TITANIUM NOTARY FILES (회전식 nickel-titanium file을 이용한 유치의 근관치료)

  • Seo, Ju-Hee;Lee, Kwang-Hee;Kim, Dae-Eop;Yang, Kye-Sik
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.620-625
    • /
    • 2001
  • The pulpectomy or root canal treatment on primary teeth is to be done when there is evidence of chronic in flammation or necrosis in the radicular pulp. Due to the tortuous and ribbon-shaped anatomy of the primary teeth, the instrumentation of endodontic hand files and barbed broaches is not an easy procedure. Recently, many automatic Ni-Ti rotary instruments have been developed and has made endodontic treatment easier and faster. This report describes two cases of root canal treatment on primary molars using Ni-Ti rotary files. The cervical constricture was eliminated by the crown-down method, as smaller file proceeded unhindered into the apical third of the canal. In addition, the crown-down technique enhanced the efficacy of the endodontic irrigant. The use of rotary instrumentation for primary teeth seemed to be a more effective way to debride the uneven walls of primary teeth.

  • PDF