• Title/Summary/Keyword: New-Ring Test

Search Result 82, Processing Time 0.023 seconds

A NEW SYSTEM OF VISUAL PRESENTATION OF ANALYSIS OF TEST PERFORMANCE: THE 'DOUBLE-RING' DIAGRAM

  • Stefadouros Miltiadis A.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.142-149
    • /
    • 1994
  • Substitution of graphic representation for extensive lists of numerical statistical data is highly desirable by both editors and readers of medical journals, faced with an exploding abundance of contemporary medical literature. A novel graphic tool. the 'double-ring diagram', is described herein which permits visual representation of information regarding certain statistical variables used to describe the performance of a test or physical sign in the diagnosis of a disease. The diagram is relatively easy to construct on the basis of a number of primary data such as the prevalence and the true positive, true negative. false positive and false negative test results. These values are reflected in the diagram along with the values of other statistical variables derived from them. such as the sensitivity. specificity, predictive values for positive and negative test result. and accuracy. This diagram may be useful in visualizing a test's performance and facilitating visual comparison of performance of two or more tests.

  • PDF

The Development of Wall Membrane for LNG Storage Tank (LNG 저장탱크용 벽체 멤브레인 개발)

  • Oh, B.T.;Hong, S.H.;Yoon, I.S.;Kim, Y.K.;Seo, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.907-912
    • /
    • 2001
  • KOGAS had developed the Ring-knot membrane for LNG storage tank. But we found that some modifications were needed in using the Ring-knot membrane for the commercial LNG storage tanks. So, both analytical and experimental studies have been performed to investigate the strength of the new membrane and the reaction force at the anchor point. Using nonlinear FEM code and experiments, the stress analysis of the new corrugated membrane shapes subject to the cryogenic liquid pressure and thermal loading are performed to ensure the stability and fatigue strength of the new membrane. This paper reports on the results of investigations into this new type of membrane.

  • PDF

Development and Performance Evaluation of a Sealing-Type Abutment Inserted with a Gold Ring (골드링을 이용한 완전 밀폐형 어버트먼트 개발 및 성능평가)

  • Hong, Dae Sun;Jeon, Yong-Jae;Lee, Hyeon-Yeol;Lee, Seung Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-103
    • /
    • 2016
  • When chewing forces are repetitively applied to a dental implant, gaps are often generated at the interface surfaces between the abutment and the fixture, which results in some deterioration, such as loosening of the fastening screw, dental retraction, and fixture fractures. To cope with such problems, a sealing-type abutment having a number of grooves along the conical-surface circumference was previously developed, and it showed better sealing performance than conventional ones. To enhance the sealing performance, a new model in which a gold ring is inserted into the top groove of the sealing-type abutment is developed in this study. In addition, a manufacturing process is developed, and performance evaluations, such as fatigue and sealing tests, are carried out. The evaluation results show that the gold-ring-inserted sealing abutment yields better performance than conventional ones.

A Development of Measurement System for Diathesis-Diagnosis (체질 진단을 위한 센서 시스템의 개발)

  • Jung, Yong-Rae;Kim, Seong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.260-263
    • /
    • 2001
  • This paper is to develop the sensing system for opening-force measurement such as O-Ring muscular meridian. We designed to overcome the functional limit that the conventional force-sensor can measure just the closing-force. Therefore, the new sensor can meet a variety of application as well as O-Ring test. The structure of the new sensor is an actuator-type system using an electromagnet. That is made up of mechanical system, electromagnet, current transformer and computer interface circuit. Driving software and user interface program of the new sensor system also is explained in this paper.

  • PDF

Effect of Cellular Phone User's Self Image to select Ring-Tone and Ring-Back-Tone (휴대전화 이용자 자아이미지가 벨소리와 통화연결음 선택에 미치는 영향)

  • Yang, Soung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.182-193
    • /
    • 2012
  • Recent growth of ring-tone and ring-back-tone download market as the derived market of cellular phone yields the new trend in music consumption from listening to display. This means that consumer purchase the ring-tone and RBT not for his appreciation but for counterpart's consumption, in a word, conspicuous consumption. Study aims at questions on whether cellular phone user can perceive the ring-tone and RBT's brand personality and how they express their self-image via ring-tone and RBT. Survey was administered for 196 college students who is dominant purchase group of market segment. Hypotheses are such as : congruity of self image and brand personality of ring-tone and RBT. Through the T-test, findings said that user's extrovert self image are not led to ring-tone's extrovert brand personality and user's introvert self image are not led to introvert ring-tone's brand personality of ringtone. same result was applicable to RTB. Cellular phone user's purchase behavior are different from those of product and service.

A Study on Objective Diagnosis of constitutions by Laser Stimulation and O-Ring Measurement Systems of Muscular Meridians (레이저 자극과 O-Ring 경근 측정시스템에 의한 체질진단의 객관화에 관한 연구)

  • Kim, Y.Y.;Kim, J.M.;Lee, E.W.;Jeong, D.M.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.173-178
    • /
    • 1995
  • This paper relates the occidental constitutional theory to the oriental one, concluding their origins to be similar, and demonstrates a new method of constitutional diagnosis by O-Ring Measurement System Of Muscular Meridians and Laser Constitutional Diagnosis. It establishes Laser Constitutional Diagnosis(L.C.D) using laser beams according to the principles of acupuncture and Sa-Sang constitutional physiology under the effect of spatial morphological energy of geometric isomers. Finally, hypothetical theory of L.C.D. was experimented by the O-Ring Measurement Systems of Muscular Meridians(O-R MSMM). O-R MSMM has been specially devised to improve the manual O-Ring Test prevailing to distinguish energetic response by muscle tonicity. Statistically, it has been proved that the constitutional diagnosis with O-R MSMM was highly effective and objective in the clinical experiences.

  • PDF

Synthesis, Characterization and Antimicrobial Activity of New Thiadiazole Derivatives

  • Mullick, Pooja;Khan, Suroor A.;Verma, Surajpal;Alam, Ozair
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2345-2350
    • /
    • 2010
  • A series of thiadiazole derivatives were synthesized with differently substituted benzoic acids which were cyclized to give differently substituted thiazolidin-4-one. Elemental analysis, IR, $^1H$ NMR, $^{13}C$ NMR and mass spectral data confirmed the structure of the newly synthesized compounds. The derivatives of these moieties were evaluated for antimicrobial activity. Most of the synthesized compounds showed good antimicrobial activity at 200 and $100\;{\mu}g/mL$. Compounds showed most significant antibacterial activity against gram negative test organism Escherichia coli and most significant antifungal activity against test organisms Aspergillus niger and Candida albicans. It was observed that compounds with $OCH_3$ at 3, 4 position of phenyl ring [5(a-l)] were more potent against microbes as compared to compounds having unsubstituted phenyl ring [4(a-l)].

Helium Leak Test for the PLS Storage Ring Chamber (포항가속기 저장링챔버의 헬륨누설검사)

  • Choi, M.H.;Kim, H.J.;Choi, W.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.31-38
    • /
    • 1993
  • The storage ring vacuum system for the Pohang Light Source (PLS) has been designed to maintain the vacuum pressure of $10^{-10}Torr$ which requires UHV welding to have helium leak rate less than $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$. In order to develop new technique (PLS) welding technique), a prototype vacuum chamber has been welded by using Tungsten Inert Gas welding method and all the welded joints have been tested with a non-destructive method, so called helium leak detection, to investigate the vacuum tightness of the weld joints. The test was performed with a detection limit of $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$ for helium and no detectable leaks were found for all the welded joints. Thus the performance of welding technique is proven to meet the criteria of helium leak rate required in the PLS Storage Ring. Both the principle and the procedure for the helium leak detection are also discussed.

  • PDF

Setting Estimation of Cement Paste Using New-type Embedded Sensor (매입형 센서를 활용한 시멘트 풀의 응결 시간 측정)

  • Shin, Kyung-Joon;Lee, Do-Keun;Seo, Dong-Wan;Yoo, Chul-Min;Lim, Min-Hyuk;Lim, Sung-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.483-488
    • /
    • 2016
  • The present study proposes an economical embedded ring-sensor that can measure a strain behavior of cement paste and mortar in early age. Using the proposed ring-sensor, the experimental method is proposed that can measure the setting time of the cement paste and mortar conveniently. The experimental study has been conducted using the mixtures of which W/C are 0.30, 0.35, 0.40, and 0.45. From the test result, the setting times measured by convectional test methods such as vicat method and penetration resistance method are compared with the setting time proposed by this study. The result reveals that the proposed ring-sensor can effectively measure the early age behavior so that can evaluate the time when the contraction starts. In addition, the contraction starting time can be regarded as a rational setting time, which is similar to the initial setting of convectional test methods.

Cathode Side Engineering to Raise Holding Voltage of SCR in a 0.5-㎛ 24 V CDMOS Process

  • Wang, Yang;Jin, Xiangliang;Zhou, Acheng;Yang, Liu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.6
    • /
    • pp.601-607
    • /
    • 2015
  • A set of novel silicon controlled rectifier (SCR) devices' characteristics have been analyzed and verified under the electrostatic discharge (ESD) stress. A ring-shaped diffusion was added to their anode or cathode in order to improve the holding voltage (Vh) of SCR structure by creating new current discharging path and decreasing the emitter injection efficiency (${\gamma}$) of parasitic Bipolar Junction Transistor (BJT). ESD current density distribution imitated by 2-dimensional (2D) TCAD simulation demonstrated that an additional current path exists in the proposed SCR. All the related devices were investigated and characterized based on transmission line pulse (TLP) test system in a standard $0.5-{\mu}m$ 24 V CDMOS process. The proposed SCR devices with ring-shaped anode (RASCR) and ring-shaped cathode (RCSCR) own higher Vh than that of Simple SCR (S_SCR). Especially, the Vh of RCSCR has been raised above 33 V. What's more, their holding current is kept over 800 mA, which makes it possible to design power clamp with SCR structure for on chip ESD protection and keep the protected chip away from latch-up risk.