• Title/Summary/Keyword: New patients

Search Result 3,488, Processing Time 0.039 seconds

Evaluation of an ELISA kit for the Serodiagnosis of Pulmonary Tuberculosis by Using Mixed Antigens of Mycobacterium Tuberculosis (폐결핵진단에서 결핵균 혼합항원을 이용한 혈청학적 검사의 유용성에 관한연구)

  • Park, Seung-Kyu;Kim, Phil-Ho;Kim, Seung-Chul;Choi, In-Hwan;Cho, Sang-Nae;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.558-567
    • /
    • 2000
  • Background : Recently, serologic techniques for tuberculosis have been developed and some of them, which are focusing on detection of serum antibodies mainly directed against specific 38-kDa Mycobacterium tuberculosis, have already been introduced into the markel. In this study, diagnostic significance of a new serologic test(ELISA kit) for pulmonary tuberculosis was evaluated. Method : Serologic test with newly developed ELISA kit was performed upon 474 individuals, who include 333 active pulmonary tuberculosis patients, 80 healthy cases, and 61 tuberculosis contact cases. This serologic test was based on the ELISA technique and designed to detect antibodies to mixed complex antigens including 38-kDa, which were developed by Erume Biotech Co., Seoul. Active pulmonary tuberculosis was diagnosed by sputum AFB smear and culture methods. Results : The seropositivities using this ELISA kit were 82.1% and 73.6% in smear-positive and negative groups among active pulmonary tuberculosis, respectively. And, it also showed that seronegativities were 97.5% and 85.2% in healthy and contact groups, respectively. As a whole, the results of our study using the ELISA kit as a diagnostic method for pulmonary tuberculosis showed 80.0% sensitivity for active pulmonary tuberculosis, 97.5% specificity, 96.1% positive predictive value, and 65.0% negative predictive value when the prevalence of tuberuclosis in the samples was 60.1%. Conclusion : Our results reveal that the detection of antibody its reaction with 38-kDa antigen of M. tuberculosis is not sufficient to be accepted as single diagnostic method for pulmonary tuberculosis. However, they suggest that ELISA kit may be considered as an adjunctive test to standard diagnostic techniques of pulmonary tuberculosis.

  • PDF

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

A Comparison of Minilaparotomy and Laparoscopic Sterilization (Minilaparotomy 불임술(不妊術)과 복강경불임술(腹腔鏡不妊術)에 관(關)한 비교연구(比較硏究))

  • Bai, Byoung-Choo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • Anderson(1937), Power and Barnes(1941) reported a study concerning a method of tubal sterilization in association with peritoneoscopy or laparoscopy in which they cauterized the tubes. There appears to have been a hiatus of interest in sterilization (cold or hot) associated with laparoscopy until reintroduction by Palmer(1963), Frangenheim(1964) and Steptoe(1967). On the other hand, for interval female sterilization, however, minilaparotomy is relatively new. By Saunder and Munsick(1972), John Lyle(1974), Frank Stubb(1974), Vitoon(1973) and B.C. Bai(1975), their own technique for interval female sterilization requires 2.0 to 2.5cm, incision at the margin of the mons pubis. In Korea, female sterilization by means of minilaparotomy firstly reported by B.C. Bai using Bai's uterine elevator, of his own device, early in 1975. Recently inteval female sterilization by laparoscopy and minilaparotomy are widely accepted throughout the world especially in Asian countries. Minilaparotomy is carried out from 1974, laparoscopic sterilization from 1976, and in this study each of 250 cases of those were analysed and discussed for the comparison at Seoul Red Cross Hospital. (1) In the age distribution, numerous clients were in their age of $31{\sim}35$ in laparoscopy as well as minilaparotomy. Average 33.7 years in L and 33.2 years in M. (M=minilaparotomy, L=laparoscopic sterilization) (2) As regarding living children, women having 3 children represented the greatest number, 113 cases out of 250 in M group and 102 cases out of 250 in L group. Average No. of child are 2.9 in Land 3.1 in M. (3) Concidering the operation day in the menstrml cycle, the greatest number of cases, those who underwent tubal sterilization during the days of $26{\sim}$, next during the $6{\sim}10$ days of the cycle in both group. (4) Concidering the operation time, 188 cases by laparoscopy were performed in $6{\sim}10$ minutes, 33 cases within 5 minutes and 24 cases in $11{\sim}15$ minutes. Maximum 50 minutes, minimum 4 minutes and average 8.3 minutes. The majority of cases (154 cases) by minilaparotomy required $6{\sim}10$ minutes and 67 cases $11{\sim}15$ minutes, 6 cases within 5 minutes. Maximum 30 minutes, minimum 4 minutes and average 10.4, minutes. In both groups, most of the reasons for the extra length were surgical difficulties such as thick abdominal wall, pelvic adhesion, less cooperation of patients in early period of this study. (5) Hospital stay after operation in L group required $3{\sim}4$ hours in 125 cases, $2{\sim}3$ hours in 41 cases, $4{\sim}5$ hours in 32 cases out of 250. Maximum 8 hours, minimum 1 hour and average 3.8 hours. In M group hospital stay required $6{\sim}7$ hours in 100 cases, over 7 hours in 85 cases, $5{\sim}6$ hours in 46 cases and so on. Maximum 14 hours, minimum 2 hours and average 6.5 hours. (6) The time between operation and gas passing in the majority cases of both groups, were $12{\sim}36$ hours. A veragetime 20.3 hours in L and 27.2 in M. (7) Laparoscopic sterilization coincident with induced abortion were carried out in 27 cases, laparoscopy with minilaparotomy to control for mesosalpingeal hemorrhage in 1 case. Minilaparotomy coincident with induced abortion were performed in 65 cases, D and C whit polypectomy, menstrual regulatian, and remaval of IUD in 1 case respectively. (8) In L group, 1 case of mesosalpingeal hemorrhage, 1 case of abdominal wall infection were complicated during operation. In M group, 1 case of uterine perfaration, 1 case of abdominal wall infection, 1 case of hemorrhage from omentum and 1 case of bloody vaginal discharge were complicated. No intensive medical treatment was required for those minor complications in both groups. (9) No failure has been recognized and these two sterilization techniques might be the simple, safe and the most effective method for permanent contraception at present time. There is no significant clinical defference between L and M group in this study.

  • PDF

Genetic Characteristics and Virulence Factors of Pandemic Vibrio parahaemolyticus Isolated in South Korea and Japan (한국과 일본에서 유행하는 장염비브리오의 병원성 인자와 유전자의 특성)

  • Hong, Seuk-Won;Moon, Ji-Young;Lee, Bok-Kwon;Kim, Yung-Bu
    • Journal of Life Science
    • /
    • v.17 no.3 s.83
    • /
    • pp.386-395
    • /
    • 2007
  • A total of 27 strains of Vibrio parahaemolyticus (18 strains isolated from Korea and 9 strains from Japan) were serotyped and examined for biochemical characteristics, antimicrobial susceptibility patterns, cytotoxicity assay, thermostable direct hemolysin (TDH) production and molecular epidemiology. Using polymerase chain reaction (PCR) method and DNA probe hybridization method, the strains were tested for toxR, tdh, trh and ORF 8 genes. The V. parahaemolyticus isolated from patients were belonged to 8 different serotypes : O3:K6, O1:K38, O3:K57, O4:K9, O4:Kl2, O4:K68, O5:Kl5 and O6:K46. Urease-positive strain possessed the trh gene, and conversely, urease-negative strains lacked the gene, indicating that urease production by V. parahemolyticus strains strongly correlates with the possession of the trh gene. Most strains showed multiple resistant to more than three antibiotics and the antibiogram could be classified into 6 group (I to VI). All of the O3:K6 strains isolated in South Korea and Japan producted TDH at high levels. The TDH titers ranged between 256 and 2.048, and the average titer was 1009. To distinguish the new and increasingly common V. parahaemolyticus strains from clinical isolates, ORF 8 is a useful genetic marker. After Southern hybridization, the HindIII restriction fragment patterns of the tdh gene were grouped one type, respectively. One type showed two bands one of which was 4.3kb and the other was 11.5kb in size. Variation between the O3:K6 serotype are minor when compared to the differences seen with the non O3:K6 strains. The migration patterns of Not I -digested of the total DNA of the O3:K6 strains were similar, and only slight variations were observed between the serotypes. By contrast, the O3:K6 strains and non O3:K6 had markedly different profiles. In conclusion, Random amplified polymorphic DNA (RAPD) profile using appropriate primers was an effective epidemiological marker.

Biodistribution of $^{99m}Tc$-Lactosylated Serum Albumin in Mice with Diethylnitrosamine or Thiacetamide Induced Liver Injury (Diethylnitrosamine 및 Thioacetamide 유발 간손상 생쥐에서의 $^{99m}Tc$-Lactosylated Serum Albumin의 체내 분포상)

  • Whang, Jae-Seok;Ahn, Byeong-Cheol;Sung, Young-Ok;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jung-Soo;Jeong, Jae-Min;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.200-208
    • /
    • 2005
  • Purpose: Tc-99m labeled diethylenetriaminepentaacctic acid (DTPA)-coupled galactosylated human serum albumin (GSA) is a currently used imaging agent for asialoglycoprotein receptor (ASGPR) of the liver, but, it has several shortcomings. Recently a new ASGPR imaging agent, $^{99m}Tc$-lactosylated human serum albumin (LSA), with simple labeling procedure, high labeling efficiency, high stability was developed. In order to assess the feasibility of the $^{99m}Tc$-LSA as a ASGPR imaging radiopharmaceuticals, we performed biodistribution study of the tracer in liver injured mice model and the results were compared with histolgic data. Materals and Methods: To induce hepatic damage in ICR mice, diethylnitrosamine (DEN) ($60mg/kg/week{\times}5time$, low dose or $180mg/kg/week{\times}2times$, high dose) and thioacetamide (TAA) ($50mg/kg{\times}1time$) were administrated intraperitoneally. Degree of liver damage was evaluated by tissue hematoxilin-eosin stain, and expression of asialoglycoprotein receptor (ASGPR) was assessed by immunohistochemistry using ASGPR antibody. $^{99m}Tc$-LSA was intravenously administrated via tail vein in DEN or TAA treated mice, and biodistribution study of the tracer was also performed. Results: DEN treated mice showed ballooning of hepatocyte and inflammatory cell infiltration in low dose group and severe hapatocyte necrosis in high dose group, and low dose group showed higher ASGPR staining than control mice in immunohistochemical staining. TAA treated mice showed severe hepatic necrosis. $^{99m}Tc$-LSA Biodistribution study showed that mice with hepatic necrosis induced by high dose DEN or TAA revealed higher blood activity and lower liver activity than control mice, due to slow clearance of the tracer by the liver. The degree of liver uptake was inversely correlated with the degree of histologic liver damage. But low dose DEN treated mice with mild hepatic injury showed normal blood clearance and hepatic activity, partly due to overexpression of ASGPR in mice with mild degree hepatic injury. Conclusion: Liver uptake of $^{99m}Tc$-LSA was inversely correlated with degree of histologic hepatic injury in DEN and TAA treated mice. These results support that $^{99m}Tc$-LSA can be used to evaluate the liver status in liver disease patients.

Increase of Tc-99m RBC SPECT Sensitivity for Small Liver Hemangioma using Ordered Subset Expectation Maximization Technique (Tc-99m RBC SPECT에서 Ordered Subset Expectation Maximization 기법을 이용한 작은 간 혈관종 진단 예민도의 향상)

  • Jeon, Tae-Joo;Bong, Jung-Kyun;Kim, Hee-Joung;Kim, Myung-Jin;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.344-356
    • /
    • 2002
  • Purpose: RBC blood pool SPECT has been used to diagnose focal liver lesion such as hemangioma owing to its high specificity. However, low spatial resolution is a major limitation of this modality. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. We compared this new modified iterative reconstruction method, OSEM with conventional filtered back projection (FBP) in imaging of liver hemangioma. Materials and Methods: Sixty four projection data were acquired using dual head gamma camera in 28 lesions of 24 patients with cavernous hemangioma of liver and these raw data were transferred to LINUX based personal computer. After the replacement of header file as interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging. The best condition for imaging in our investigation was considered to be 4 iterations and 16 subsets. After then, all the images were processed by both FBP and OSEM. Three experts reviewed these images without any information. Results: According to blind review of 28 lesions, OSEM images revealed at least same or better image quality than those of FBP in nearly all cases. Although there showed no significant difference in detection of large lesions more than 3 cm, 5 lesions with 1.5 to 3 cm in diameter were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions less than 1.5 cm. Conclusion: OSEM revealed better contrast and define in depiction of liver hemangioma as well as higher sensitivity in detection of small lesions. Furthermore this reconstruction method dose not require high performance computer system or long reconstruction time, therefore OSEM is supposed to be good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.

Antibiotic Susceptibility of Salmonella spp. Isolated From Diarrhoea Patients in Seoul From 1996 to 2001 (서울 시내 설사환자에서 분리한 살모넬라의 항생제 감수성의 년도별 변화 추이)

  • 박석기;박성규;정지헌;진영희
    • Journal of Food Hygiene and Safety
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2002
  • In order to investigate the classification and antibiotic resistance of Salmonella species,718 isolates were isolated from patient in Seoul from 1996 to 2001. The two hundred and ninety eight isolates (41.5%) were identified as Sal. Enteritidis, followed by Sal. Typhi 218 isolates (30.4%), and Sal. Typhimurium 87 isolates (12.1%). The identified Salmonella species were most resistant to tetracycline (32.7%), followed by streptomycin (28.0%), ticarcillin (18.1%) and ampicillin (12.4%). Among isolates,34.7% of Sal. Enteritidis were resistant to tetracycline, 32.3% to streptomycin,23.2% to ticarcillin,13.5% to ampicillin, respectively. 13.8% of Sal. Typhi were resistant to streptomycin,10.6% to tetracycline, respectively.66.7% of Sal. Typhimurium were resistant to tetracycline, 42.5% to streptomycin, 28.7% to ticarcillin, 26.4% to ampicillin and 17.2% to chloramphenicol, respectively. Of 718 isolates, 324 isolates (45.1%) were resistant to 1 or more drugs and 64 isolates (19.8%) were resistant to 1 drug, 132 isolates (40.7%) were resistant to 2 drugs,50 isolates (15.4%) were resistant to 3 drugs, 27 isolates (8.3%) to 4 drugs,27 isolates (8.3%) to 5 drugs,22 Isolates (6.8%) to 6 drugs. The most prevalent multiple resistant pattern was tetracycline-kanamycin (35.5%), followed by tetracycline-kanamycin-ticarcillin (8.3%), and tetracycline-kanamycin-ticarcillin-ampicillin (7.4%) . Antibiotic resistant rate of Sal. Typhimurium was 73.6%,1311owe4 by Sal. Enteritidis 53.7% and Sal. Typhi 19.3%. Most Sal. Enteritidis was resistant to 1 drug o.2 drugs, whereas Sal. Typhi. and Sal.. Typhunurium were more .resistant to 5 (16.7%) or 6 drugs (26.6%). The old generation antibiotics such as ampicillin, tetracycline, and streptomycin were annually more resistant than the new generation antibiotics such as ceftriaxone, ciprofloxacin or cefoxitin.

Fragment Analysis for Detection of the FLT3-Internal Tandem Duplication: Comparison with Conventional PCR and Sanger Sequencing (FLT3-ITD 검출을 위한 절편분석법: 일반 중합효소연쇄반응 및 직접염기서열분석법과의 비교)

  • Lee, GunDong;Kim, Jeongeun;Lee, SangYoon;Jang, Woori;Park, Joonhong;Chae, Hyojin;Kim, Myungshin;Kim, Yonggoo
    • Laboratory Medicine Online
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • Background: We evaluated a sensitive and quantitative method utilizing fragment analysis of the fms-like tyrosine kinase 3-internal tandem duplication (FLT3-ITD), simultaneously measuring mutant allele burden and length, and verified the analytical performance. Methods: The number and allelic burden of FLT3-ITD mutations was determined by fragment analysis. Serial mixtures of mutant and wild-type plasmid DNA were used to calculate the limit of detection of fragment analysis, conventional PCR, and Sanger sequencing. Specificity was evaluated using DNA samples derived from 50 normal donors. Results of fragment analysis were compared to those of conventional PCR, using 481 AML specimens. Results: Defined mixtures were consistently and accurately identified by fragment analysis at a 5% relative concentration of mutant to wild-type, and at 10% and 20% ratios by conventional PCR and direct sequencing, respectively. No false positivity was identified. Among 481 AML specimens, 40.1% (193/481) had FLT3-ITD mutations. The mutant allele burden (1.7-94.1%; median, 28.2%) and repeated length of the mutation (14-153 bp; median, 49 bp) were variable. The concordance rate between fragment analysis and conventional PCR was 97.7% (470/481). Fragment analysis was more sensitive than conventional PCR and detected 11 additional cases: seven had mutations below 10%, three cases represented conventional PCR failure, and one case showed false negativity because of short ITD length (14 bp). Conclusions: The new fragment analysis method proved to be sensitive and reliable for the detection and monitoring of FLT3-ITD in patients with AML. This could be used to simultaneously assess ITD mutant allele burden and length.

Demand for the Radiological Technologist Independent Act for the Performance of the Duties of a Radiological Technologist (방사선사 직무수행을 위한 방사선사 단독법 제정에 대한 요구도)

  • Kim, Eun-Hye;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Moon, Young-Ju;Kim, Hoon;Jung, Young-Jin;Choi, Ji-Won;Yoon, Yong-Su;Cho, Pyong-Kon;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.525-534
    • /
    • 2021
  • In order to provide high-quality medical services to the public and contribute to the improvement of public health, it is necessary to enact an independent law according to the work of radiological technologists. Therefore, this study intends to review the regulations related to radiographers in the Medical Service Technologists, etc. Act. and to present opinions and directions for enactment of individual laws for radiological technologists. An online survey was conducted to 15,000 radiological technologists working in medical institutions and education sites in Korea; 1,027 people (6.85%) responded. The questionnaire consisted of 3 questions on demographic characteristics, 5 questions on the scope of work, and 12 questions on the revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological Technologist Independent Act. Reliability and factor analysis were performed on 9 questions measured on a Likert 5-point scale in "Revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological echnologist Independent Act" among the questionnaire items. Reliability for the total 9 questions was Chronbach α=0.728. There was a high perception that the regulations related to radiological technologists were insufficient in the current Medical Service Technologists, etc. Act., and the perception that examinations performed by radiological technologists at medical institutions were included in medical practice was high. If the Radiological Technologist Independent Act is enforced, a high percentage of respondents said that they could receive legal protection through the institutionalization of the scope of work, that the status of radiological technologists would be improved, and the scope of work would be expanded. The response that the scope of work of radiological technologists should be included was the highest at 96.6%. In the analysis according to demographic characteristics, it was found that 96.7% of the respondents were agreed regardless of the factors. Radiological technologists will have to work hard to secure the public health by coping with new radiology devices, procedures and treatment methods. Therefore, as the results of this study, it is expected that the enactment and implementation of the Radiological Technologist Independent Act will contribute to the improvement of the quality of treatment for patients and to the public health.