• Title/Summary/Keyword: New correction factor

Search Result 309, Processing Time 0.027 seconds

Third Harmonic Injection Circuit to Eliminate Electrolytic Capacitors in Light-Emitting Diode Drivers

  • Yoo, Jin-Wan;Jung, Kwang-Hyun;Jeon, In-Ung;Park, Chong-Yeun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.358-365
    • /
    • 2012
  • A new third harmonic injection circuit for light-emitting diode (LED) drivers is proposed to eliminate electrolytic capacitors and thereby extend the lifetime of LED drivers. When a third harmonic current is injected to the input current of the LED driver, the required capacitance of the driver can be reduced. The proposed circuit can control an injection ratio and has simple circuitry. The synchronous third harmonic is generated by a phase locked loop (PLL), a 1/3 counter, and op-amps and applied to a power factor correction circuit. Thus, the storage capacitor can install film capacitors instead of the electrolytic capacitor. The value of storage capacitance can be reduced to 78% compared to an input power factor of 100%. The proposed circuit is applied to the 80W prototype LED driver to experimentally verify the performances.

A Novel Switching Mode for High Power Factor Correction and Low THD

  • Park, Gyumin;Eum, Hyunchul;Yang, Seunguk;Hwang, Minha;Park, Inki
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.210-212
    • /
    • 2018
  • A new switching mode has been proposed to obtain high power factor and low THD in single stage AC-DC converter. The conventional voltage mode control in critical conduction mode distorts input current shape with poor THD in flyback topology. Once TRIAC dimmer is connected, visible flicker in the LED lamp is easily detected due to a lack of TRAIC holding current near the input voltage zero cross. The newly proposed method can shape the input current by providing a desired reference voltage so that low THD is obtained by ideal sinusoidal input current in case of no dimmer connection and flat input current performs good TRIAC dimmer compatibility in phase-cut dimming condition. To confirm the validity of the proposed method, theoretical analysis and experimental result from 8W dimmable LED lighting system are presented.

  • PDF

Activity Coefficients and Coulombic Correction Factor for Surface Complexation Modeling

  • Rhee, In-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.146-155
    • /
    • 2002
  • Surface complexation models employ mass law equations to describe the reaction of surface functional groups with ions in the solution and also Gouy-Chapman theory to consider the electrostatic effects in the surface reactions. In current surface complexation models, however, the coulombic factors used are not wholly consistent with the Gouy-Chapman model of the surface. This study was to provide the derivation of the coulombic term usually employed and then a revised coulombic term completely consistent with Gouy-Chapman Theory. The electrical potential energy. zF${\psi}$, in current surface complexation models is not consistent with the Gouy-Chapman theory with the potential gradient close to the charged surface but with the Donnan model with the uniform potential. Even though the new coulombic factor yielded lower surface potential, it provided worse fits for acid-base titration data of the goethite suspensions.

  • PDF

On-board charger equipped with new power factor corrected circuit for plug-in hybrid electric vehicle (새로운 역률보상회로를 적용한 플러그인 하이브리드 전기차 탑재용 완속 충전기)

  • Kim, Seong-hye;Lee, Ju-young;Kang, Feel-soon
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.140-141
    • /
    • 2012
  • 본 논문은 새로운 역률보상회로를 적용한 플러그인 하이브리드 전기 자동차 탑재형 완속 충전기(On-Board Charger, OBC)를 제안한다. 제안하는 완속 충전기용 역률보상회로 (Power Factor Correction, PFC)는 기존의 부스트 컨버터를 기본으로 하는 역률보상회로와 동일한 개수의 회로 부품과 입 출력전압 관계를 가진다. 회로 구조상 전파 정류된 DC 전압을 저장하는 입력 커패시터와 입력 인덕터의 에너지가 저장되는 출력 커패시터가 직렬 결합되어 DC-link 전압을 형성하므로 출력 커패시터의 동작전압(Working voltage)을 낮출 수 있어 단가절감이 가능하다. 제안된 역률보상 회로를 적용한 플러그인 하이브리드 전기 자동차 탑재형 완속 충전기에 대한 동작 특성을 해석하고 시뮬레이션을 통해 타당성을 검증한다.

  • PDF

Three-Phase Diode Rectifier Employing Soft Switching Methods (소프트 스위칭 방식의 삼상 다이오드 정류기)

  • Moon, Gun-Woo;Lee, Jung-Hoon;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.847-849
    • /
    • 1993
  • Two new schemes of three-phase rectifier using softing switching methods are introduced for the input power factor correction. These three-phase rectifiers are employed the zero voltage switching for the parallel resonant and zero current switching for the series resonant AC link type rectifiers. The dynamic modeling and discontinuous integral cycle mode control technique are also presented. With the proposed circuits and control technique, the high power factor can be obtained.

  • PDF

The study on the high performance continuous input current type PWM AC/DC boost converter using one semiconduction switch (단일 스위칭소자를 이용한 전류연속형 PWM AC/DC 부스터 콘버어터의 고역율 구현에 관한 연구)

  • Park, Sung-Jun;Byun, Young-Bok;Kim, Kwang-Tae;Kwon, Soon-Jae;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.379-381
    • /
    • 1995
  • Many new electronic products are required to have a near unity power factor and a distortion free input current waveform. In this paper, a high performance single phase PWM AC/DC converter with input power factor correction is proposed. This proposed control strategy has many advantages which include one semiconduction switch, simplified control circuit, high performance features and continuous input current. The experimental results are included to verify the validity of this approach.

  • PDF

A MONTE CARLO METHOD FOR SOLVING HEAT CONDUCTION PROBLEMS WITH COMPLICATED GEOMETRY

  • Shentu, Jun;Yun, Sung-Hwan;Cho, Nam-Zin
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.207-214
    • /
    • 2007
  • A new Monte Carlo method for solving heat conduction problems is developed in this study. Differing from other Monte Carlo methods, it is a transport approximation to the heat diffusion process. The method is meshless and thus can treat problems with complicated geometry easily. To minimize the boundary effect, a scaling factor is introduced and its effect is analyzed. A set of problems, particularly the heat transfer in the fuel sphere of PBMR, is calculated by this method and the solutions are compared with those of an analytical approach.

Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite (COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증)

  • Moon, Yun Seob;Lee, Kangyeol
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.420-433
    • /
    • 2016
  • The purpose of this study is to improve the calibration matrixes of 2-D and 3-D convective rainfall rates (CRR) using the brightness temperature of the infrared $10.8{\mu}m$ channel (IR), the difference of brightness temperatures between infrared $10.8{\mu}m$ and vapor $6.7{\mu}m$ channels (IR-WV), and the normalized reflectance of the visible channel (VIS) from the COMS satellite and rainfall rate from the weather radar for the period of 75 rainy days from April 22, 2011 to October 22, 2011 in Korea. Especially, the rainfall rate data of the weather radar are used to validate the new 2-D and 3-DCRR calibration matrixes suitable for the Korean peninsula for the period of 24 rainy days in 2011. The 2D and 3D calibration matrixes provide the basic and maximum CRR values ($mm\;h^{-1}$) by multiplying the rain probability matrix, which is calculated by using the number of rainy and no-rainy pixels with associated 2-D (IR, IR-WV) and 3-D (IR, IR-WV, VIS) matrixes, by the mean and maximum rainfall rate matrixes, respectively, which is calculated by dividing the accumulated rainfall rate by the number of rainy pixels and by the product of the maximum rain rate for the calibration period by the number of rain occurrences. Finally, new 2-D and 3-D CRR calibration matrixes are obtained experimentally from the regression analysis of both basic and maximum rainfall rate matrixes. As a result, an area of rainfall rate more than 10 mm/h is magnified in the new ones as well as CRR is shown in lower class ranges in matrixes between IR brightness temperature and IR-WV brightness temperature difference than the existing ones. Accuracy and categorical statistics are computed for the data of CRR events occurred during the given period. The mean error (ME), mean absolute error (MAE), and root mean squire error (RMSE) in new 2-D and 3-D CRR calibrations led to smaller than in the existing ones, where false alarm ratio had decreased, probability of detection had increased a bit, and critical success index scores had improved. To take into account the strong rainfall rate in the weather events such as thunderstorms and typhoon, a moisture correction factor is corrected. This factor is defined as the product of the total precipitable waterby the relative humidity (PW RH), a mean value between surface and 500 hPa level, obtained from a numerical model or the COMS retrieval data. In this study, when the IR cloud top brightness temperature is lower than 210 K and the relative humidity is greater than 40%, the moisture correction factor is empirically scaled from 1.0 to 2.0 basing on PW RH values. Consequently, in applying to this factor in new 2D and 2D CRR calibrations, the ME, MAE, and RMSE are smaller than the new ones.

A Study on Input Current Waveform Analysis for Step Up-Down AC-DC Converter of High Power Factor added Electric Isolation (고역률 스텝 업-다운 절연형 AC-DC 컨버터의 입력전류 파형분석에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Choon-Sam;Lee, Bong-Seob;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.34-36
    • /
    • 2008
  • This paper is given a full detail of mathematical analyses of input current for novel active type power factor correction(PFC) AC-DC converter of step up-down added electric isolation. These are compared with harmonics components of input current for a conventional PFC converter of electric isolation type. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode(DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of a conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

  • PDF

High Power Factor Three Phase Rectifier for High Power Density AC/DC Conversion Applications

  • Cho, J.G.;Jeong, C.Y.;Baek, J.W.;Song, D.I.;Yoo, D.W.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.648-653
    • /
    • 1998
  • The conventional three-phase rectifier with bulky LC output filter has been widely used in the industry because of its distinctive advantages over the active power factor correction rectifier such as simple circuit, high reliability, and low cost. Over than 0.9 power factor can be achieved, which is acceptable in most of industry applications. This rectifier, however, is not easy to use for high power density applications since the LC filter is bulky and heavy. To solve this problem, a new simple rectifier is presented in this paper. By eliminating the bulky LC filter from the conventional diode rectifier without losing most of the advantages of the conventional rectifier, very high power density power conversion with high power factor can be achieved. Operation principle and design considerations are illustrated and verified by Pspice simulation and experimental results from a prototype of 3.3 kW rectifier followed by 100KHz zero voltage switching full bridge PWM converter

  • PDF