• 제목/요약/키워드: New correction factor

검색결과 311건 처리시간 0.025초

다차로도로의 서비스수준 분석을 위한 속도보정계수 개선에 관한 연구 (New Speed Adjustment Factor for Analyzing Level of Service at Multi-Lane Highway)

  • 김원길;강원의;노창균;박범진
    • 한국도로학회논문집
    • /
    • 제14권6호
    • /
    • pp.167-173
    • /
    • 2012
  • PURPOSES : This study is to develop speed correction factor for more realistic Level-of-Service(LOS) at multilane highway. METHODS : In this study, we compared speed difference the degree of speed reductions in actual multilane road conditions with speed reduction considering speed correction factor presented in highway capacity manual using statistical techniques. And also we presents new speed correction factor analyzing collected data at national highway No.1 (Goyang~Wolrung). RESULTS : The result of analyzing and comparing new suggested speed correction factor with speed correction factor in Korea Highway Capacity Manual (KHCM) shows RMSE (Root Mean Square Error) in new speed correction factor (RMSE 1.5) is much lower than existing speed correction factor (RMSE 13.4). New suggested speed correction can be used for analyzing Level-of-Service at multilane highway. And also we suggests improvements for analysis procedure in analyzing Level-of-Service at multilane highway CONCLUSIONS : As a result of comparing differences, we draw the causes that effect the differences in speed and suggest new speed correction factor that consider traffic volumes. It can be more rational because it uses speed correction factor which can consider more realistic traffic conditions, etc.

공공건축물에 적용되는 신·재생에너지원의 새로운 보정계수 제안 (Proposal of New Correction Factors for New and Renewable Energy Sources in Public Building)

  • 김윤호;박윤하;원안나;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.13-24
    • /
    • 2016
  • The government introduced a mandatory installation system of new & renewable energy for public building to meet the target of greenhouse gas reduction and also suggest a correction factor for new renewable energy to expand the installation of various new & renewable energy systems. The introduction of correction factors, however, was followed by the reduction of installation size of new & renewable energy sources. Assuming that it was caused by a correction factor for each new renewable energy source calculated by the initial costs, this study proposed a new correction factor approach based on payback periods to reflect the technology element in the calculation process of correction factors additionally. The application results of new correction factors show that it was possible to do complex calculations including the economic and technological aspects to select a new & renewable energy system and that the installation size was also enlarged.

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권2호
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

  • Obais, Abdulkareem Mokif;Pasupuleti, Jagadeesh
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.742-753
    • /
    • 2014
  • In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is connected to an AC source via a series first harmonic filter. The harmonic-suppressed TCR is designed so that negligible harmonic current components are injected into the AC source. The compensator is equipped with a new adaptive closed loop current controller, which responds linearly to reactive current demands. The no load operating losses of this compensator are negligible when compared to its capacitive reactive current rating. The proposed system is validated on PSpice which is very close in terms of performance to real hardware.

Development of the Boated Length to Diameter Correction Factor on Critical Heat Flux Using the Artificial Neural Networks

  • Lee, Yong-Ho;Chun, Tae-Hyun;Beak, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.443-448
    • /
    • 1998
  • With using artificial neural networks (ANNs), an analytical study related to the heated length effect on critical heat flux(CHF) has been carried out to make an improvement of the CHF prediction accuracy based on local condition correlations or table. It has been carried out to suggest a feasible criterion of the threshold length-to-diameter (L/D) value in which heated length could affect CHF. And within the criterion, a L/D correction factor has been developed through conventional regression. In order to validate the developed L/D correction factor, CHF experiment for various heated lengths have been carried out under low and intermediate pressure conditions. The developed threshold L/D correlation provides a new feasible criterion of L/D threshold value. The developed correction factor gives a reasonable accuracy fur the original database, showing the error of -2.18% for average and 27.75% for RMS, and promising results for new experimental data.

  • PDF

변압기 자화 에너지를 이용한 새로운 단일전력단 고역률 컨버터 (New Single-Stage High Power Converter Using Transformer Magnetizing Energy)

  • 문건우;노정욱;정영석;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.35-38
    • /
    • 1996
  • A new high power factor converter using transformer magnetizing energy for power factor correction with a single-switch/single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF

저가격 형광등용 전자식 안정기에 적합한 새로운 역률개선회로 (Novel High Power Factor Correction Circuit for Low-Cost Electronic Ballasts)

  • 채균;윤용식;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2072-2074
    • /
    • 1997
  • A new low-cost high power factor correction circuit for electronic ballasts is proposed. The proposed circuit provides good power factor correction, low current harmonic distortion and cost-effectiveness. The prototype meets the IEC555-2 requirements satisfactorily with nearly unity power factor.

  • PDF

능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터 (An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correction Converter with Active Clamp Circuit)

  • 이준영;문건우;고관본;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.626-630
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi-resonant converter (QRC) for the power factor correction(PFC) converter is introduced in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of an input current. The proposed converter has the characteristics of the good power factor, low line current harmonics, and tight output regulation. Furthermore, the ringing effect due to the output capacitance of the main switch can be eliminated by use of active clamp circuit.

  • PDF

결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터 (New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit)

  • 박경수;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권10호
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

보정계수 산출에 의한 신광원용 표준램프 광속의 검증 (The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor)

  • 황명근;신상욱;이진우
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.