Risk Perception of the Firefighters Responsible for Nuclear Power Plants: Construct Validity (원자력발전소 화재에 대한 관할 지역 소방관의 위험인식: 측정도구의 개발과 타당화)

  • Choi, HaeYoun;Lee, SangKyu;Choi, Jong-An
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.94-102
    • /
    • 2019
  • As the importance of first responses for fire accidents has grown in the safety management of nuclear power plants, a systematic approach to measure firefighters' psychological states and competence is needed. The current study investigated the construct of the risk perception of the firefighters working near nuclear power plant sites, and then developed and validated a new scale to measure firefighters' risk perception regarding nuclear power plant accidents. The scale items were developed on the basis of literature review and interviews with the firefighters working near nuclear power plant sites. In order to validate the new scale, we recruited 180 firefighters from five fire stations in the vicinity of the nuclear power plants in Jeonnam Province, Gyeongbuk Province, and Busan. The results of exploratory factor analyses revealed that the scale consisted of five factors: "manual" reflecting a lack of response guidelines and manuals for fire incidents and radioactive material release; "fear" reflecting a fear of fire incidents in the nuclear power plants and their catastrophic consequences; "resource" reflecting a lack of protective equipment and manpower for responding to fire incidents in the nuclear power plants; "trust" reflecting trust and cooperation with the counterpart institutions for firefighting in the nuclear power plants; and "knowledge" reflecting the knowledge of radioactivity and firefighting in the nuclear power plants. Further analyses provided statistical evidence supporting for the 15-item scale's internal consistency and construct validity. Finally, We discussed the implication and limitations of the current research.

AM600: A New Look at the Nuclear Steam Cycle

  • Field, Robert M.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.621-631
    • /
    • 2017
  • Many developing countries considering the introduction of nuclear power find that large-scale reactor plants in the range of 1,000 MWe to 1,600 MWe are not grid appropriate for their current circumstance. By contrast, small modular reactors are generally too small to make significant contributions toward rapidly growing electricity demand and to date have not been demonstrated. This paper proposes a radically simplified re-design for the nuclear steam cycle for a medium-sized reactor plant in the range of 600 MWe. Historically, balance of plant designs for units of this size have emphasized reliability and efficiency. It will be demonstrated here that advances over the past 50 years in component design, materials, and fabrication techniques allow both of these goals to be met with a less complex design. A disciplined approach to reduce component count will result in substantial benefits in the life cycle cost of the units. Specifically, fabrication, transportation, construction, operations, and maintenance costs and expenses can all see significant reductions. In addition, the design described here can also be expected to significantly reduce both construction duration and operational requirements for maintenance and inspections.

Dose Evaluation of Neutron within Containment Building of a CE type Nuclear Power Plant (CE형 원전의 격납건물내 중성자선량 평가)

  • Kim Tae Wook;Han Jae Mun;Kim Kyung Doek;Yun Cheol Whan;Suh Jang Soo;Kim Young Jae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.23-30
    • /
    • 2005
  • From measured results of the neutron fields at some principal places within the containment building in a CE type nuclear power plant in operation, the radiation exposure of a worker to the neutron at there was evaluated and the equivalent dose reflecting new recommendation (ICRP 60) was compared with that doing the old one (ICRP 26). The measured neutron field was also compared with calibration neutron field. From the analysis, the following conclusion was obtained: the average neutron radiation weighting factor according to new recommendation is 2.41 to 2.71 times higher than the old one. The average neutorn radiation weighting factor at the measured place was similar to that at calibration neutron field. The average neutron energy at measured place was between 42 and 158 keV and higher than that of calibration field of 500 keV. So, the measured equivalent dose in nuclear power plant could be overestimated compared to the real equivalent dose.

  • PDF

OTEC System using the Condenser Effluent from Nuclear Power Plant a feasibility study (원자력 발전소의 온배수를 이용한 해양온도차 발전의 타당성 검토)

  • Shin, Sangwoong;Chun, Wongee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.238.2-238.2
    • /
    • 2010
  • Recently, environmental pollution and energy depletion problems have been issued over the world. For this reason, many renewable systems have been developing. Of these, the Ocean Thermal Energy Conservation(OTEC) is drawing attention as the upcoming alternative energy source. In this paper, the efficiency of each of OTEC which harness the effluent from nuclear power plant was analyzed by using computer calculation. The result, shows that Ul-jin Nuclear Power Plant is the best place geographically and the regenerative cycle is most outstanding performance cycle for OTEC. The difference of temperature between surface water and deep water temperature should be greater than $20^{\circ}C$ in order to increase the efficiency.

  • PDF

Performance Evaluation Test for Applying the Mechanical Development of the High-Strength Reinforcing Bars to the Nuclear Power Plant Structures (고강도철근 기계적정착의 원전구조물 적용을 위한 성능평가실험)

  • Lee, Byung-Soo;Bang, Chang-Joon;Lim, Sang-Joon;Kim, Seok-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.197-198
    • /
    • 2012
  • If the mechanical development be applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the re-bar yield strength and diameter. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

A Study on the Availability Assessment Method for Instrumentation and Control System of Nuclear Power Plant (원자력발전소의 제어계측 시스템에 대한 가용도 평가 방법 연구)

  • Lee, Dong-Hee;Nam, Kyung-H.
    • Journal of Applied Reliability
    • /
    • v.10 no.2
    • /
    • pp.149-160
    • /
    • 2010
  • This paper presents a study of an availability evaluation for I&C(Instrumentation and Control) System which it applied for nuclear power plant. The system availability assessment have been implemented to the reactor protection system by the adoption of Markov process. Results are satisfied to the requirement of EPRI and APR1400. Based on the research of I&C system assessment, it will contribute to improve the availability of system and impact the design concept with new design optimization.

The Technology Development for applying the High Strength Headed Deformed Bar to the Nuclear Power Plant Structures (원전구조물의 확대머리 고강도철근 적용기술 개발)

  • Lee, Byung-Soo;Bang, Chang-Joon;Lee, Han-Woo;Lim, Sang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.273-275
    • /
    • 2013
  • If the mechanical development is applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the yield strength and diameter of the re-bar. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

Today's Nuclear Challenge: Maintenance and Radiation Exposure

  • Willis, Chales A.
    • Nuclear Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.159-165
    • /
    • 1975
  • The Nuclear power industry today faces a serious and rapidly emerging problem in reactor maintenance and occupational radiation exposure control. The basic problem is the need for much maintenance on nuclear power plants. The problem is seriously compounded by radiation exposure control requirements. Many studies are underway seeking solutions tut the industry is developing rapidly and new plants will not await the results of such studies. It is essential that attention be given to maintenance and exposure control in all phases of plant design, construction and operation.

  • PDF

Proposal of a prototype plant based on the exfoliation process for the treatment of irradiated graphite

  • Pozzetto, Silvia;Capone, Mauro;Cherubini, Nadia;Cozzella, Maria Letizia;Dodaro, Alessandro;Guidi, Giambattista
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.797-801
    • /
    • 2020
  • Most of irradiated graphite that should be disposed comes from moderators and reflectors of nuclear power plants. The quantity of irradiated graphite could be higher in the future if high-temperature reactors (HTRs) will be deployed. In this case noteworthy quantities of fuel pebbles containing semi-graphitic carbonaceous material should be added to the already existing 250,000 tons of irradiated graphite. Industry graphite is largely used in industrial applications for its high thermal and electrical conductivity and thermal and chemical resistance, making it a valuable material. Irradiated graphite constitutes a waste management challenge owing to the presence of long-lived radionuclides, such as 14C and 36Cl. In the ENEA Nuclear Material Characterization Laboratory it has been successfully designed a procedure based on the exfoliation process organic solvent assisted, with the purpose of investigate the possibility of achieving graphite significantly less toxic that could be recycled for other purpose [1]. The objective of this paper is to evaluate the possibility of the scalability from laboratory to industrial dimensions of the exfoliation process and provide the prototype of a chemical plant for the treatment of irradiated graphite.

New design of variable structure control based on lightning search algorithm for nuclear reactor power system considering load-following operation

  • Elsisi, M.;Abdelfattah, H.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.544-551
    • /
    • 2020
  • Reactor control is a standout amongst the most vital issues in the nuclear power plant. In this paper, the optimal design of variable structure controller (VSC) based on the lightning search algorithm (LSA) is proposed for a nuclear reactor power system. The LSA is a new optimization algorithm. It is used to find the optimal parameters of the VSC instead of the trial and error method or experts of the designer. The proposed algorithm is used for the tuning of the feedback gains and the sliding equation gains of the VSC to prove a good performance. Furthermore, the parameters of the VSC are tuned by the genetic algorithm (GA). Simulation tests are carried out to verify the performance and robustness of the proposed LSA-based VSC compared with GA-based VSC. The results prove the high performance and the superiority of VSC based on LSA compared with VSC based on GA.