• Title/Summary/Keyword: New Methods Development

Search Result 3,535, Processing Time 0.063 seconds

Development and Evaluation of Multiplex PCR for the Detection of Carbapenemase-Producing Enterobacteriaceae (카바페넴분해효소 생성 장내세균 검출을 위한 Multiplex PCR의 개발 및 평가)

  • Kim, Si Hyun;Bae, Il Kwon;Kim, Na Young;Song, Sae Am;Kim, Sunjoo;Jeong, Joseph;Shin, Jeong Hwan
    • Annals of Clinical Microbiology
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2019
  • Background: The isolation of carbapenemase-producing Enterobacteriaceae (CPE) has become increasingly common. Continuous surveillance for these organisms is essential because their infections are closely related to outbreaks of illness and are associated with high mortality rates. The aim of this study was to develop and evaluate multiplex PCR as a means of detecting several important CPE genes simultaneously. Methods: We aimed to develop a multiplex PCR that could detect seven CPE genes simultaneously. The multiplex PCR was composed of seven primer sets for the detection of KPC, IMP, VIM, NDM-1, GES, OXA-23, and OXA-48. We designed different PCR product sizes of at least 100 bp. We evaluated the performance of this new test using 69 CPE-positive clinical isolates. Also, we confirmed the specificity to rule out false-positive reactions by using 71 carbapenem-susceptible clinical strains. Results: A total of 69 CPE clinical isolates showed positive results and were correctly identified as KPC (N=14), IMP (N=13), OXA-23 (N=12), OXA-48 (N=11), VIM (N=9), GES (N=5), and NDM (N=5) by the multiplex PCR. All 71 carbapenem-susceptible clinical isolates, including Enterococcus faecalis, Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, and Pseudomonas aeruginosa, showed negative results. Conclusion: This multiplex PCR can detect seven CPE genes at a time and will be useful in clinical laboratories.

Research Trends of Health Recommender Systems (HRS): Applying Citation Network Analysis and GraphSAGE (건강추천시스템(HRS) 연구 동향: 인용네트워크 분석과 GraphSAGE를 활용하여)

  • Haryeom Jang;Jeesoo You;Sung-Byung Yang
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.2
    • /
    • pp.57-84
    • /
    • 2023
  • With the development of information and communications technology (ICT) and big data technology, anyone can easily obtain and utilize vast amounts of data through the Internet. Therefore, the capability of selecting high-quality data from a large amount of information is becoming more important than the capability of just collecting them. This trend continues in academia; literature reviews, such as systematic and non-systematic reviews, have been conducted in various research fields to construct a healthy knowledge structure by selecting high-quality research from accumulated research materials. Meanwhile, after the COVID-19 pandemic, remote healthcare services, which have not been agreed upon, are allowed to a limited extent, and new healthcare services such as health recommender systems (HRS) equipped with artificial intelligence (AI) and big data technologies are in the spotlight. Although, in practice, HRS are considered one of the most important technologies to lead the future healthcare industry, literature review on HRS is relatively rare compared to other fields. In addition, although HRS are fields of convergence with a strong interdisciplinary nature, prior literature review studies have mainly applied either systematic or non-systematic review methods; hence, there are limitations in analyzing interactions or dynamic relationships with other research fields. Therefore, in this study, the overall network structure of HRS and surrounding research fields were identified using citation network analysis (CNA). Additionally, in this process, in order to address the problem that the latest papers are underestimated in their citation relationships, the GraphSAGE algorithm was applied. As a result, this study identified 'recommender system', 'wireless & IoT', 'computer vision', and 'text mining' as increasingly important research fields related to HRS research, and confirmed that 'personalization' and 'privacy' are emerging issues in HRS research. The study findings would provide both academic and practical insights into identifying the structure of the HRS research community, examining related research trends, and designing future HRS research directions.

Association of Lifestyle Factors With the Risk of Frailty and Depressive Symptoms: Results From the National Survey of Older Adults (노인의 라이프스타일 요인이 허약 및 우울 위험도에 미치는 영향: 노인실태조사 자료를 바탕으로)

  • Lim, Seungju;Kim, Ah-Ram;Park, Kang-Hyun;Yang, Min-Ah;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.13 no.1
    • /
    • pp.35-47
    • /
    • 2024
  • Objective : This study aimed to investigate the association between lifestyle factors and risk of frailty and depressive symptoms among older South Korean adults. Methods : This study included 10,072 individuals aged 65 or older from the 2017 National Survey of Older Koreans, a cohort of community-dwelling older South Koreans. The following lifestyle factors were assessed: physical activity, nutrition management (NM), and leisure/social activity participation (AP). Frailty was measured using the frail scale and depressive symptoms were measured using the Geriatric Depression Scale. Logistic regression analyses were performed to determine the odds ratios. Results : All lifestyle factors were associated with the risk of frailty and depressive symptoms in the study population. Regular exercise (≥3 times/wk, odds ratio [OR] = 0.59, 95% confidence interval [95% CI] = 0.52~0.91; OR = 0.66, 95% CI = 0.59~0.75), active NM (OR = 0.86, 95% CI = 0.80~0.91; OR = 0.81, 95% CI = 0.76~0.86), leisure AP (OR = 0.79, 95% CI = 0.74~0.84; OR = 0.71, 95% CI = 0.66~0.77) and social AP (OR = 0.92, 95% CI = 0.88~0.96; OR = 0.82, 95% CI = 0.78~0.87) were correlated with lower odds ratios of frailty and depressive symptoms. Conclusion : Adopting a healthier lifestyle characterized by regular exercise, balanced nutrition, and active engagement in various activities can effectively reduce the risk of frailty and depressive symptoms among the older population. Ultimately, this study emphasized the essential role of lifestyle choices in promoting the physical and mental well-being of older adults.

The Effects of Consumer Value Cognition on Benefits and Attributes of Culture-Art Products (문화예술상품 소비자의 가치인식이 추구혜택과 상품속성에 미치는 영향)

  • Shin, Eun Joo;Rhee, Young Sun
    • Asia Marketing Journal
    • /
    • v.14 no.2
    • /
    • pp.177-207
    • /
    • 2012
  • Today's consumers perceive consumption as a representation of themselves. It is not simply an act that fulfills a consumer's physical and practical needs. Even in terms of life quality, consumers increasingly want to achieve an emotional and sensible experience through consumption. Consumers now make decisions based on their need to express their position in relation to other people, pursue emotional satisfaction, and try to improve the quality of life. Culture-art products that meet such internal and external demands of consumers have made significant improvements in both quantity and quality, because of the social interest and policy support. The recognition of personal and social values of culture and arts has brought about interest in and need for culture-art products. Businesses have agilely embraced such change and actively implemented various marketing strategies utilizing culture and arts. For example, businesses began to sponsor artists who produce culture-art products while building facilities for cultural and art performances or exhibitions. Businesses have also provided performances and exhibitions free-of-charge or at affordable prices. As a result, the supply in the market has started to exceed its demand as is often the case in many of other markets. However, such imbalance has occurred not because of over-supply but because of a lack of demand. Given these circumstances, the government and culture and art related organizations, which had mainly concentrated on the supply side, started to recognize the importance of creating personal and social values in culture and arts. As a result, the government and various organizations are now creating various strategies that include policy measures to achieve their new found goal. Unfortunately however, such efforts are not meeting the expectations. Focusing on above-mentioned circumstances and problems, this study aims to find measures to create demand for culture-art products in the internal conditions of those who consume culture-art products. In other words, given that the demand for culture-art products has not increased despite all external conditions to encourage consumption, this study aims to find the reasons in consumers' value judgment on culture-art products. Though there were recent studies on culture-art products that applied consumer behavior on marketing theories, most of them focused on peripheral aspects such as people's motivation for or satisfaction from watching culture-art events. Hence, there is a need to understand what kind of value consumers perceive from culture-art products and how such value cognition leads to consumption in a comprehensive manner. This study acts as follow-up to a separate study entitled "Qualitative Study about Value Cognition and Benefits of Consumer on Culture-Art Products". The current study aims to extend practical implications that enhance the effectiveness of marketing strategies among the producing and policy agencies in the industry. The purpose of this study is to investigate dimensions of value cognition, benefits and attributes of culture-art products, and identify the effects of consumer value cognition on benefits and attributes. The questionnaire was developed based on the conceptual structure of qualitative research and previous researches. It was composed of value cognition, benefits, attributes of culture-art products and demographic variables. This survey was conducted on-line and off-line among a total of 662 persons ranging from their teens to their 50's who were living in Seoul, Gyeonggi-do, various metropolitan cities, and small and medium-sized cities. The data collected was analyzed by factor analysis and path analysis using SPSS WIN 18.0 and AMOS 16.0. This empirical study found that the dimensions of value cognition of culture-art products were categorized into personal goods, aesthetic goods and public property. This shows that the consumers perceive culture-art products as products that are worthy enough to pay the costs not just for personal benefits but also for their social values. Also the formation of value cognition for culture-art products requires special conditions unlike that for physical consumer goods and services, which simply require marketing stimuli. The dimensions of benefits pursued by consuming culture-art products were found to be composed of four types - pursuit of aesthetic benefits, pursuit of actual benefits, pursuit of emotional benefits, and pursuit of conspicuous character. This result implies that people consume culture-art products not just to pursue pleasure from emotional and intelligent satisfaction as well as social relations, but also to seek the needs and benefits embodied at a social level. The dimensions of attributes of culture-art products had seven different factors, - environmental, price, evaluation, people, artwork, composition, and personal relations - which is plentiful. This is because the attributes of culture-art products are very complicated compared to other consumer goods or services. Since culture-art products include not just cultural or artistic works but also all physical, human, environmental, and systemic elements of the products in a comprehensive manner, consumers perceive everything they experience in the process of consuming culture-art products as part of the products. The dimensions of value cognition was found to affect attributes of the products, mostly using pursued benefits as a mediating factors. This result is consistent with the result of qualitative research, and proves that applying the means-end chain theory in the reverse direction is reasonable. The result can be interpreted that consumers' value cognitions for culture-art products turns into actual benefits leading to consumers' decisions. Furthermore, this result reveals that when consumers choose culture-art products, they take into account the attributes of culture-art products depending on the benefits they pursue. These results confirm that despite their conceptual and abstract attributes, culture-art products have values that contribute to actual benefits for individual consumers and society. Hence, value cognition generates benefits to be pursued and this in turn affects the consumers' choices of attributes on products. Based on the conceptual structure of consumers' value cognitions on culture-art products and its dimensions, it is possible to find detailed methods to provide opportunities for education and training to form and reinforce positive value cognition on culture-art products. And through those methods, it will be possible to develop attributes of culture-art products according to the dimensions of pursued benefits, and allow conceptual products become the subject to valuable consumption in real life. These results provide theoretical understanding of consumer behavior in culture marketing and useful information to culture-art producers, companies that use culture and art, and government agencies that use culture-art as a mean to improve the public perception of quality of life. As a follow up on this study, there should be experimental studies that can develop criteria visualizing the demands of consumers who purchase culture-art products and identify their detailed attributes. Studies that compare characteristics of different areas within the culture-art product category and in-depth studies on a specific area or genre will also be needed. In order to develop marketing strategies for culture-art products, studies on the formation and reinforcement of positive value cognition on culture-art products and education for the development of consumer demand as well as on the development and differentiation of attributes of culture-art products depending on types of consumer groups should also follow.

  • PDF

The State Hermitage Museum·Northwest University for Nationalities·Shanghai Chinese Classics Publishing House Kuche Art Relics Collected in Russia Shanghai Chinese Classics Publishing House, 2018 (아라사국립애이미탑십박물관(俄羅斯國立艾爾米塔什博物館)·서북민족대학(西北民族大學)·상해고적출판사(上海古籍出版社) 편(編) 『아장구자예술품(俄藏龜玆藝術品)』, 상해고적출판사(上海古籍出版社), 2018 (『러시아 소장 쿠차 예술품』))

  • Min, Byung-Hoon
    • MISULJARYO - National Museum of Korea Art Journal
    • /
    • v.98
    • /
    • pp.226-241
    • /
    • 2020
  • Located on the right side of the third floor of the State Hermitage Museum in St. Petersburg, the "Art of Central Asia" exhibition boasts the world's finest collection of artworks and artifacts from the Silk Road. Every item in the collection has been classified by region, and many of them were collected in the early twentieth century through archaeological surveys led by Russia's Pyotr Kozlov, Mikhail Berezovsky, and Sergey Oldenburg. Some of these artifacts have been presented around the world through special exhibitions held in Germany, France, the United Kingdom, the Netherlands, Korea, Japan, and elsewhere. The fruits of Russia's Silk Road expeditions were also on full display in the 2008 exhibition The Caves of One Thousand Buddhas - Russian Expeditions on the Silk Route on the Occasion of 190 Years of the Asiatic Museum, held at the Hermitage Museum. Published in 2018 by the Shanghai Chinese Classics Publishing House in collaboration with the Hermitage Museum, Kuche Art Relics Collected in Russia introduces the Hermitage's collection of artifacts from the Kuche (or Kucha) region. While the book focuses exclusively on artifacts excavated from the Kuche area, it also includes valuable on-site photos and sketches from the Russian expeditions, thus helping to enhance readers' overall understanding of the characteristics of Kuche art within the Buddhist art of Central Asia. The book was compiled by Dr. Kira Samosyuk, senior curator of the Oriental Department of the Hermitage Museum, who also wrote the main article and the artifact descriptions. Dr. Samosyuk is an internationally renowned scholar of Central Asian Buddhist art, with a particular expertise in the art of Khara-Khoto and Xi-yu. In her article "The Art of the Kuche Buddhist Temples," Dr. Samosyuk provides an overview of Russia's Silk Road expeditions, before introducing the historical development of Kuche in the Buddhist era and the aspects of Buddhism transmitted to Kuche. She describes the murals and clay sculptures in the Buddhist grottoes, giving important details on their themes and issues with estimating their dates, and also explains how the temples operated as places of worship. In conclusion, Dr. Samosyuk argues that the Kuche region, while continuously engaging with various peoples in China and the nomadic world, developed its own independent Buddhist culture incorporating elements of Gandara, Hellenistic, Persian, and Chinese art and culture. Finally, she states that the culture of the Kuche region had a profound influence not only on the Tarim Basin, but also on the Buddhist grottoes of Dunhuang and the central region of China. A considerable portion of Dr. Samosyuk's article addresses efforts to estimate the date of the grottoes in the Kuche region. After citing various scholars' views on the dates of the murals, she argues that the Kizil grottoes likely began prior to the fifth century, which is at least 100 years earlier than most current estimates. This conclusion is reached by comparing the iconography of the armor depicted in the murals with related materials excavated from the surrounding area (such as items of Sogdian art). However, efforts to date the Buddhist grottoes of Kuche must take many factors into consideration, such as the geological characteristics of the caves, the themes and styles of the Buddhist paintings, the types of pigments used, and the clothing, hairstyles, and ornamentation of the depicted figures. Moreover, such interdisciplinary data must be studied within the context of Kuche's relations with nearby cultures. Scientific methods such as radiocarbon dating could also be applied for supplementary materials. The preface of Kuche Art Relics Collected in Russia reveals that the catalog is the first volume covering the Hermitage Museum's collection of Kuche art, and that the next volume in the series will cover a large collection of mural fragments that were taken from Berlin during World War II. For many years, the whereabouts of these mural fragments were unknown to both the public and academia, but after restoration, the fragments were recently re-introduced to the public as part of the museum's permanent exhibition. We look forward to the next publication that focuses on these mural fragments, and also to future catalogs introducing the artifacts of Turpan and Khotan. Currently, fragments of the murals from the Kuche grottoes are scattered among various countries, including Russia, Germany, and Korea. With the publication of this catalog, it seems like an opportune time to publish a comprehensive catalog on the murals of the Kuche region, which represent a compelling mixture of East-West culture that reflects the overall characteristics of the region. A catalog that includes both the remaining murals of the Kizil grottoes and the fragments from different parts of the world could greatly enhance our understanding of the murals' original state. Such a book would hopefully include a more detailed and interdisciplinary discussion of the artifacts and murals, including scientific analyses of the pigments and other materials from the perspective of conservation science. With the ongoing rapid development in western China, the grotto murals are facing a serious crisis related to climate change and overcrowding in the oasis city of Xinjiang. To overcome this challenge, the cultural communities of China and other countries that possess advanced technology for conservation and restoration must begin working together to protect and restore the murals of the Silk Road grottoes. Moreover, centers for conservation science should be established to foster human resources and collect information. Compiling the data of Russian expeditions related to the grottoes of Kuche (among the results of Western archaeological surveys of the Silk Road in the early twentieth century), Kuche Art Relics Collected in Russia represents an important contribution to research on Kuche's Buddhist art and the Silk Road, which will only be enhanced by a future volume introducing the mural fragments from Germany. As the new authoritative source for academic research on the artworks and artifacts of the Kuche region, the book also lays the groundwork for new directions for future studies on the Silk Road. Finally, the book is also quite significant for employing a new editing system that improves its academic clarity and convenience. In conclusion, Dr. Kira Samosyuk, who planned the publication, deserves tremendous praise for taking the research of Silk Road art to new heights.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

A Study for Improvement of Nursing Service Administration (병원 간호행정 개선을 위한 연구)

  • 박정호
    • Journal of Korean Academy of Nursing
    • /
    • v.3 no.1
    • /
    • pp.13-40
    • /
    • 1972
  • Much has teed changed in the field of hospital administration in the It wake of the rapid development of sciences, techniques ana systematic hospital management. However, we still have a long way to go in organization, in the quality of hospital employees and hospital equipment and facilities, and in financial support in order to achieve proper hospital management. The above factors greatly effect the ability of hospitals to fulfill their obligation in patient care and nursing services. The purpose of this study is to determine the optimal methods of standardization and quality nursing so as to improve present nursing services through investigations and analyses of various problems concerning nursing administration. This study has been undertaken during the six month period from October 1971 to March 1972. The 41 comprehensive hospitals have been selected iron amongst the 139 in the whole country. These have been categorized according-to the specific purposes of their establishment, such as 7 university hospitals, 18 national or public hospitals, 12 religious hospitals and 4 enterprise ones. The following conclusions have been acquired thus far from information obtained through interviews with nursing directors who are in charge of the nursing administration in each hospital, and further investigations concerning the purposes of establishment, the organization, personnel arrangements, working conditions, practices of service, and budgets of the nursing service department. 1. The nursing administration along with its activities in this country has been uncritical1y adopted from that of the developed countries. It is necessary for us to re-establish a new medical and nursing system which is adequate for our social environments through continuous study and research. 2. The survey shows that the 7 university hospitals were chiefly concerned with education, medical care and research; the 18 national or public hospitals with medical care, public health and charity work; the 2 religious hospitals with medical care, charity and missionary works; and the 4 enterprise hospitals with public health, medical care and charity works. In general, the main purposes of the hospitals were those of charity organizations in the pursuit of medical care, education and public benefits. 3. The survey shows that in general hospital facilities rate 64 per cent and medical care 60 per-cent against a 100 per cent optimum basis in accordance with the medical treatment law and approved criteria for training hospitals. In these respects, university hospitals have achieved the highest standards, followed by religious ones, enterprise ones, and national or public ones in that order. 4. The ages of nursing directors range from 30 to 50. The level of education achieved by most of the directors is that of graduation from a nursing technical high school and a three year nursing junior college; a very few have graduated from college or have taken graduate courses. 5. As for the career tenure of nurses in the hospitals: one-third of the nurses, or 38 per cent, have worked less than one year; those in the category of one year to two represent 24 pet cent. This means that a total of 62 per cent of the career nurses have been practicing their profession for less than two years. Career nurses with over 5 years experience number only 16 per cent: therefore the efficiency of nursing services has been rated very low. 6. As for the standard of education of the nurses: 62 per cent of them have taken a three year course of nursing in junior colleges, and 22 per cent in nursing technical high schools. College graduate nurses come up to only 15 per cent; and those with graduate course only 0.4 per cent. This indicates that most of the nurses are front nursing technical high schools and three year nursing junior colleges. Accordingly, it is advisable that nursing services be divided according to their functions, such as professional, technical nurses and nurse's aides. 7. The survey also shows that the purpose of nursing service administration in the hospitals has been regulated in writing in 74 per cent of the hospitals and not regulated in writing in 26 per cent of the hospitals. The general purposes of nursing are as follows: patient care, assistance in medical care and education. The main purpose of these nursing services is to establish proper operational and personnel management which focus on in-service education. 8. The nursing service departments belong to the medical departments in almost 60 per cent of the hospitals. Even though the nursing service department is formally separated, about 24 per cent of the hospitals regard it as a functional unit in the medical department. Only 5 per cent of the hospitals keep the department as a separate one. To the contrary, approximately 12 per cent of the hospitals have not established a nursing service department at all but surbodinate it to the other department. In this respect, it is required that a new hospital organization be made to acknowledge the independent function of the nursing department. In 76 per cent of the hospitals they have advisory committees under the nursing department, such as a dormitory self·regulating committee, an in-service education committee and a nursing procedure and policy committee. 9. Personnel arrangement and working conditions of nurses 1) The ratio of nurses to patients is as follows: In university hospitals, 1 to 2.9 for hospitalized patients and 1 to 4.0 for out-patients; in religious hospitals, 1 to 2.3 for hospitalized patients and 1 to 5.4 for out-patients. Grouped together this indicates that one nurse covers 2.2 hospitalized patients and 4.3 out-patients on a daily basis. The current medical treatment law stipulates that one nurse should care for 2.5 hospitalized patients or 30.0 out-patients. Therefore the statistics indicate that nursing services are being peformed with an insufficient number of nurses to cover out-patients. The current law concerns the minimum number of nurses and disregards the required number of nurses for operation rooms, recovery rooms, delivery rooms, new-born baby rooms, central supply rooms and emergency rooms. Accordingly, tile medical treatment law has been requested to be amended. 2) The ratio of doctors to nurses: In university hospitals, the ratio is 1 to 1.1; in national of public hospitals, 1 to 0.8; in religious hospitals 1 to 0.5; and in private hospitals 1 to 0.7. The average ratio is 1 to 0.8; generally the ideal ratio is 3 to 1. Since the number of doctors working in hospitals has been recently increasing, the nursing services have consequently teen overloaded, sacrificing the services to the patients. 3) The ratio of nurses to clerical staff is 1 to 0.4. However, the ideal ratio is 5 to 1, that is, 1 to 0.2. This means that clerical personnel far outnumber the nursing staff. 4) The ratio of nurses to nurse's-aides; The average 2.5 to 1 indicates that most of the nursing service are delegated to nurse's-aides owing to the shortage of registered nurses. This is the main cause of the deterioration in the quality of nursing services. It is a real problem in the guest for better nursing services that certain hospitals employ a disproportionate number of nurse's-aides in order to meet financial requirements. 5) As for the working conditions, most of hospitals employ a three-shift day with 8 hours of duty each. However, certain hospitals still use two shifts a day. 6) As for the working environment, most of the hospitals lack welfare and hygienic facilities. 7) The salary basis is the highest in the private university hospitals, with enterprise hospitals next and religious hospitals and national or public ones lowest. 8) Method of employment is made through paper screening, and further that the appointment of nurses is conditional upon the favorable opinion of the nursing directors. 9) The unemployment ratio for one year in 1971 averaged 29 per cent. The reasons for unemployment indicate that the highest is because of marriage up to 40 per cent, and next is because of overseas employment. This high unemployment ratio further causes the deterioration of efficiency in nursing services and supplementary activities. The hospital authorities concerned should take this matter into a jeep consideration in order to reduce unemployment. 10) The importance of in-service education is well recognized and established. 1% has been noted that on the-job nurses. training has been most active, with nursing directors taking charge of the orientation programs of newly employed nurses. However, it is most necessary that a comprehensive study be made of instructors, contents and methods of education with a separate section for in-service education. 10. Nursing services'activities 1) Division of services and job descriptions are urgently required. 81 per rent of the hospitals keep written regulations of services in accordance with nursing service manuals. 19 per cent of the hospitals do not keep written regulations. Most of hospitals delegate to the nursing directors or certain supervisors the power of stipulating service regulations. In 21 per cent of the total hospitals they have policy committees, standardization committees and advisory committees to proceed with the stipulation of regulations. 2) Approximately 81 per cent of the hospitals have service channels in which directors, supervisors, head nurses and staff nurses perform their appropriate services according to the service plans and make up the service reports. In approximately 19 per cent of the hospitals the staff perform their nursing services without utilizing the above channels. 3) In the performance of nursing services, a ward manual is considered the most important one to be utilized in about 32 percent of hospitals. 25 per cent of hospitals indicate they use a kardex; 17 per cent use ward-rounding, and others take advantage of work sheets or coordination with other departments through conferences. 4) In about 78 per cent of hospitals they have records which indicate the status of personnel, and in 22 per cent they have not. 5) It has been advised that morale among nurses may be increased, ensuring more efficient services, by their being able to exchange opinions and views with each other. 6) The satisfactory performance of nursing services rely on the following factors to the degree indicated: approximately 32 per cent to the systematic nursing activities and services; 27 per cent to the head nurses ability for nursing diagnosis; 22 per cent to an effective supervisory system; 16 per cent to the hospital facilities and proper supply, and 3 per cent to effective in·service education. This means that nurses, supervisors, head nurses and directors play the most important roles in the performance of nursing services. 11. About 87 per cent of the hospitals do not have separate budgets for their nursing departments, and only 13 per cent of the hospitals have separate budgets. It is recommended that the planning and execution of the nursing administration be delegated to the pertinent administrators in order to bring about improved proved performances and activities in nursing services.

  • PDF

Small Animal PET Imaging with [$^{124}I$]FIAU for Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression in a Hepatoma Model (간암 동물 모델에서 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabinofuranosyl-5-[$^{124}I$iodo-uracil ($[^{124}I]FIAU$) 소동물 PET 영상 연구)

  • Chae, Min-Jeong;Lee, Tae-Sup;Kim, June-Youp;Woo, Gwang-Sun;Jumg, Wee-Sup;Chun, Kwon-Soo;Kim, Jae-Hong;Lee, Ji-Sup;Ryu, Jin-Sook;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Purpose: The HSV1-tk gene has been extensively studied as a type of reporter gene. In hepatocellular carcinoma (HCC), only a small proportion of patients are eligible for surgical resection and there is limitation in palliative options. Therefore, there is a need for the development of new treatment modalities and gene therapy is a leading candidate. In the present study, we investigated the usefulness of substrate, 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabino-furanosyi-5-[$^{124/125}I$]iodo- uracil ([$I^{124/125}I$]FIAU) as a non-invasive imaging agent for HSV1-tk gene therapy in hepatoma model using small animal PET. Material and Methods: With the Morris hepatoma MCA cell line and MCA-tk cell line which was transduced with the HSV1-tk gene, in vitro uptake and correlation study between [$^{125}I$]FIAU uptake according to increasing numeric count of percentage of MCA-tk cell were performed. The biodistribution data and small animal PET images with [$^{124}I$]FIAU were obtained with Balb/c-nude mice bearing both MCA and MCA-tk tumors. Results:, Specific accumulation of [[$^{125}I$]FIAU was observed in MCA-tk cells but uptake was low in MCA cells. Uptake in MCA-tk cells was 15 times higher than that of MCA cells at 480 min. [$^{125}I$]FIAU uptake was linearly correlated (R2 =0.964, p =0.01) with increasing percentage of MCA-tk numeric cell count. Biodistribution results showed that [$^{125}I$]FIAU was mainly excreted via the renal system in the early phase. Ratios of MCA-tk tumor to blood acting were 10, 41, and 641 at 1 h, 4 h, and 24 h post-injection, respectively. The maximum ratio of MCA-tk to MCA tumor was 192.7 at 24 h. Ratios of MCA-tk tumor to liver were 13.8, 66.8, and 588.3 at 1 h, 4 h, and 24 h, respectively. On small animal PET, [$^{124}I$]FIAU accumulated in substantial higher levels in MCA-tk tumor and liver than MCA tumor. Conclusion: FIAU shows selective accumulation to HSV1-tk expressing hepatoma cell tumors with minimal uptake in normal liver. Therefore, radiolabelled FIAU is expected to be a useful substrate for non-invasive imaging of HSV1-tk gene therapy and therapeutic response monitoring of HCC.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.