• Title/Summary/Keyword: New Medical Technology

Search Result 1,079, Processing Time 0.035 seconds

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

The vibration exercise device development which uses the sonic wave (음파를 이용한 진동운동기구개발)

  • Min, Jin-Yeong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.135-136
    • /
    • 2008
  • By applying sonic wave technology in Vibration Exercise Equipment, we introduced an completely new concept of device into the fitness and medical industry creating a new trend. Sonic Vibration Exercise Equipment which got over the limit of technology will be easily accessible not only by professional athletes but also by ordinary users and even minority groups such as disabled, elderly, children.

  • PDF

Development of sonic wave leg press system (음파를 이용한 진동 레그프래스 운동기구개발)

  • Min, Jin-Young
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1501-1504
    • /
    • 2008
  • By applying sonic wave vibration technology in weight exercise equipment, we introduced an completely new concept of device into the fitness and medical industry creating a new trend. Sonic wave leg press exercise system which got over the limit of technology will be easily accessible not only by professional athletes but also by ordinary users and even minority groups such as disabled, elderly, children.

  • PDF

Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue (레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발)

  • Lee, M.C.;Fujii, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.

Peripheral Serotonin: a New Player in Systemic Energy Homeostasis

  • Namkung, Jun;Kim, Hail;Park, Sangkyu
    • Molecules and Cells
    • /
    • v.38 no.12
    • /
    • pp.1023-1028
    • /
    • 2015
  • Whole body energy balance is achieved through the coordinated regulation of energy intake and energy expenditure in various tissues including liver, muscle and adipose tissues. A positive energy imbalance by excessive energy intake or insufficient energy expenditure results in obesity and related metabolic diseases. Although there have been many obesity treatment trials aimed at the reduction of energy intake, these strategies have achieved only limited success because of their associated adverse effects. An ancient neurotransmitter, serotonin is among those traditional pharmacological targets for anti-obesity treatment because it exhibits strong anorectic effect in the brain. However, recent studies suggest the new functions of peripheral serotonin in energy homeostasis ranging from the endocrine regulation by gut-derived serotonin to the autocrine/paracrine regulation by adipocyte-derived serotonin. Here, we discuss the role of serotonin in the regulation of energy homeostasis and introduce peripheral serotonin as a possible target for anti-obesity treatment.

Selective 3,4-Dihydroxyphenylalanine Analysis in Human Urine as Ethoxycarbonyltert-butyldimethylsilyl Derivatives by Gas Chromatography-Mass Spectrometry

  • Paik, Man-Jeong;Nguyen, Duc-Toan;Yoon, Jae-Hwan;Cho, In-Seon;Shim, Woo-Young;Kim, Kyoung-Rae;Cho, Ki-Hong;Choi, Sang-Dun;Lee, Gwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.977-980
    • /
    • 2011
  • A new analytical method for measurement of 3,4-dihydroxyphenylalanine (DOPA) in human urine was developed. DOPA from an aqueous solution was converted into an ethoxycarbonyl (EOC) derivative. A tertbutyldimethylsilyl (TBDMS) reaction under anhydrous conditions was then attempted for analysis by gas chromatography-mass spectrometry in selected ion monitoring mode. A new mass spectral data on DOPA as a tri-EOC/mono-TBDMS derivative was built. This method showed good linearity (r ${\geq}$ 0.999), precision (% relative standard deviation = 3.1-9.2), and accuracy (% relative error = -7.2-8.8), with a detection limit of 0.05 ng/mL. This selective and accurate method of DOPA analysis will be useful for biochemical monitoring of various neurological disorders including Parkinson's disease in biological fluids.

An Implementation of Discrete Mathematical Model for ECG waveform

  • Yimman, Surapun;Deeudom, Mongkon;Ittisariyanon, Jirawat;Junnapiya, Somyot;Dejhan, Kobchai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.852-856
    • /
    • 2005
  • This paper proposes a new design of the ECG simulator with high resolution by using small amount of memories based on discrete least square estimation equations instead of reading the stored data inside the look-up table. The experimental results have shown that the ECG simulator using discrete least square estimation equations can display the bipolar limb leads ECG signals with low PRD (percent root-mean-square difference) while taking the less amount of memories than the previous method which used the look-up table to store ECG data for ECG simulation.

  • PDF

Deep learning for the classification of cervical maturation degree and pubertal growth spurts: A pilot study

  • Mohammad-Rahimi, Hossein;Motamadian, Saeed Reza;Nadimi, Mohadeseh;Hassanzadeh-Samani, Sahel;Minabi, Mohammad A. S.;Mahmoudinia, Erfan;Lee, Victor Y.;Rohban, Mohammad Hossein
    • The korean journal of orthodontics
    • /
    • v.52 no.2
    • /
    • pp.112-122
    • /
    • 2022
  • Objective: This study aimed to present and evaluate a new deep learning model for determining cervical vertebral maturation (CVM) degree and growth spurts by analyzing lateral cephalometric radiographs. Methods: The study sample included 890 cephalograms. The images were classified into six cervical stages independently by two orthodontists. The images were also categorized into three degrees on the basis of the growth spurt: pre-pubertal, growth spurt, and post-pubertal. Subsequently, the samples were fed to a transfer learning model implemented using the Python programming language and PyTorch library. In the last step, the test set of cephalograms was randomly coded and provided to two new orthodontists in order to compare their diagnosis to the artificial intelligence (AI) model's performance using weighted kappa and Cohen's kappa statistical analyses. Results: The model's validation and test accuracy for the six-class CVM diagnosis were 62.63% and 61.62%, respectively. Moreover, the model's validation and test accuracy for the three-class classification were 75.76% and 82.83%, respectively. Furthermore, substantial agreements were observed between the two orthodontists as well as one of them and the AI model. Conclusions: The newly developed AI model had reasonable accuracy in detecting the CVM stage and high reliability in detecting the pubertal stage. However, its accuracy was still less than that of human observers. With further improvements in data quality, this model should be able to provide practical assistance to practicing dentists in the future.

Assignment and Analysis of New Postcode using Geographic Data (지리정보 데이터를 활용한 새우편번호 부여 및 분석에 관한 연구)

  • Lee, Jeong-Hun;Eom, Bo-Yun;Kim, In-Soo;Lee, Seong-Joon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.38 no.3
    • /
    • pp.227-236
    • /
    • 2012
  • New 5-digit zone code (new postcode) will replace the current 6-digit postcode which has been used for postal automation in 2014. New postcode will be used for processing various works to distinguish location and area in the entire country. For example, it new postcode will be used to denote different administration areas, firefighting and police jurisdiction, weather forecast areas, emergency medical facility areas, social welfare institution areas, election districts, school districts, statistical areas, courier and delivery business areas, and etc. Therefore, the relevant authorities must be cosider for the feasibility and applicability of assigning the new postcode. In postal service, postal process will be affected a lot by new postcode because a postcode has been related with delivery area of a postman. Therefore, we propose assignment scheme for new postcode which will impact less to postal process. Then, we present how we used geographic data for efficient assignment and analysis of the results.