• Title/Summary/Keyword: New Effective temperature

Search Result 457, Processing Time 0.037 seconds

A Study on the Integrated Prefab Building Materials Depending on the Cooling Type of PV Mocdule Backside (태양전지모듈 후면의 냉각조건에 따른 조립식 건축자재와 일체화에 관한 연구)

  • Yi So-Mi;Lee Yong-Ho;Hong Sung-Min
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.9-15
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, the purpose of this research is to integrated prefab building materials depending on the cooling type of PV modules. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module temperature. From the basis of these results on the correlation of temperature and irradiation were obtained.

  • PDF

A Design of Thermosiphoning Air Panel and its Performance Analyzing (자연 대류식 태양열 집열기 (TAP)의 설계와 평가)

  • Shin, H.Y.;Lee, K.H.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.51-57
    • /
    • 1984
  • The aim of the study is to the thermal performance of TAP (Thermosiphoning Air Panel) which is easily applicable to existing building as well as new building. TAP is one of the advantageous means of passive solar system, with a view to reducing the energy consumption of existing and new building. The instantaneous thermal efficency of a thermo siphoning collector depends primarily on the heat loss coefficient of the collector, the effectiveness of heattransfer between the absorber and the air, the average air temperature in the collector, the ambient air temperature, and the transmitted solar radiation. Because the important design variables are interrelated, it is, difficult to determine the effect of design decisions based on intuition. Therefore economical and effective TAP can be used easily, TAP had been designed and analyzed.

  • PDF

Mathematical Model and Numerical Analysis for Packed Bed Methanation Reactors (충전층 메탄화 반응기의 수학적 모델 및 전산 수치해석)

  • CHI, JUNHWA
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.3
    • /
    • pp.260-270
    • /
    • 2015
  • One-dimensional packed bed reactor model accounting for interfacial and intra-particle gradients was developed and based on it numerical analyses were performed to investigate the dynamic behavior of a commercial scale methanation reactor. Methanation reaction was almost complete near the reactor inlet and gases with equilibrated composition were discharged from the reactor. Both the intra-particle temperature gradient and differential surface temperature rise were found to be severe near the reactor inlet. To reduce the possible degradation or fracture of catalyst particles and prevent local overheating on the catalyst, addition of inert material can be an effective way.

Study on Sol-Gel Prepared Phosphosilicate Glass-Ceramic For Low Temperature Phosphorus Diffusion into Silicon

  • Kim, Young-Sig
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.32-36
    • /
    • 2001
  • A new solid source for low temperature diffusion into silicon was developed. The source wafer consists of an “active” compound, which is sol-gel prepared phosphosilicate glass-ceramics containing 56% P$_2$O$\sub$5/, embedded in a skeletal foam-like, inert substrate. Phosphorus diffusion from the new solid sources at low temperatures (800-875$^{\circ}C$) produced reprodecible sheet resistances and shallow junctions. From a series of one hour doping runs, the life time of the phosphosilicate source was determined to be over 40 hours. The effective diffusion coefficient of phosphorus into silicon and the corresponding activation energy at 850$^{\circ}C$ were determined to be 7.5${\times}$10$\^$-15/ $\textrm{cm}^2$/sec and ∼3.9 eV, respectively.

  • PDF

New GGNMOS I/O Cell Array for Improved Electrical Overstress Robustness

  • Pang, Yon-Sup;Kim, Youngju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.65-70
    • /
    • 2013
  • A 0.18-${\mu}m$ 3.3 V grounded-gate NMOS (GGNMOS) I/O cell array for timing controller (TCON) application is proposed for improving electrical overstress (EOS) robustness. The improved cell array consists of 20 GGNMOS, 4 inserted well taps, 2 end-well taps and shallow trench isolation (STI). Technology computer-aided design (TCAD) simulation results show that the inserted well taps and extended drain contact gate spacing (DCGS) is effective in preventing EOS failure, e.g. local burnout. Thermodynamic models for device simulation enable us to obtain lattice temperature distributions inside the cells. The peak value of the maximum lattice temperature in the improved GGNMOS cell array is lower than that in a conventional GGNMOS cell array. The inserted well taps also improve the uniformity of turn-on of GGNMOS cells. EOS test results show the validity of the simulation results on improvement of EOS robustness of the new GGNMOS I/O cell array.

Purification and Characterization of an Antilisterial Bacteriocin Produced by Leuconostoc sp. W65

  • Oh, Se-Jong;Kim, Myung-Hee;Churey, John-J.;Worobo, Randy-W.
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.5
    • /
    • pp.680-686
    • /
    • 2003
  • This study was carried out to characterize the antilisterial substances produced by Leuconostoc sp. W65 and to evaluate the effects of pH, temperature, and time on inhibitory activity using response surface methodology. Leucocin W65, an antilisterial substance produced by Leuconostoc sp. W65, markedly inhibited the growth of Listeria monocytogenes, L. innocua, and L. ivanovii, whereas other pathogens including Gram-negative bacteria were not susceptible. The pH was the most effective factor with regard to bacteriocin activity, while temperature and time of heat treatment had no significant effect. Fifty percent of inhibitory activity remained after 22.8 min at pH 4.2 and $121^{\circ}C$. Leucocin W65 was purified by ammonium sulfate precipitation, hydrophobic interaction chromatography, and tricine-SDS-PAGE. Compositional analysis originally estimated the peptide to be 56 amino acids in length without asparagine, glutamine, and tryptophane. The sequence of partial N-terminal amino acid residues of purified bacteriocin was identified as follows: $NH_{2}-XGXAGVXPXGGQQPXVPLXYP$.

Prediction of Billet Temperature by the Total Heat Exchange Factor on the Reheating Furnace (총괄열흡수율을 이용한 가열로내 소재(Billet) 온도예측)

  • Gang, Deok-Hong;Kim, Gi-Hong;Lee, Yong-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.11
    • /
    • pp.1549-1554
    • /
    • 2000
  • A new method to determine the total heat exchange factor was proposed for the prediction of billet temperature in a reheating furnace. This method employed the squared of the difference between measured and predicted temperatures as an objective function. The real billet temperature in a walking beam type reheating furnace with 19.75m of its effective length was directly measured by thermocouples. The present method was validated by showing that the predicted billet temperature was in a good agreement with the measured one.

Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator (풍력발전기 Air Guide 위치별 온도상승 해석)

  • Han, Chang-Woo;Kim, Hyun-Jae;Kweon, Ki-Yeoung;Lee, Hahk-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.282-285
    • /
    • 2008
  • In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.

  • PDF

Characteristics of thermal comfort for artificial environment experiment in summer (하계 인공환경실험에서의 온열쾌적특성)

  • 박종일;김경훈;홍희기;민병일;김창주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.368-377
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate(Electrocardiogram), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at SE $T^{*}$ 24.7$^{\circ}C$, -0.82<PMV<0.93, subject's clothing(0.41c1o)and the difference of skin temperature was found at the calf area as air temperature changes. At low SE $T^{*}$, heart rate was decreased and at high SE $T^{*}$, heart rate was increased but there was no change EEG(keeping $\alpha$-wave).wave).

  • PDF

Experimental Study on the Stimulating Effect of Commercial Moxa Combustion through the Measurement of Temperature - Focused on ascending temperature gradient and effective stimulating period - (온도 측정을 통한 상용 쑥뜸의 자극효과에 대한 실험적 연구 - 승온속도 및 유효자극기를 중심으로 -)

  • Lee, Geon-Mok;Lee, Gun-Hyee;Lee, Seung-Hoon;Yang, Myung-Bok;Go, Gi-Deok;Seo, Eun-Mi;Jang, Jong-Deok;Hwang, Byung-Chan
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.64-76
    • /
    • 2002
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion objectively and to be used as the quantitative data for developing the new thermal stimulating treatment by observing the combustion characteristics of commercial moxaes. Methods : We have selected two types(large-size moxa A(LMA), large-size moxa B(LMB)) among large moxaes used widely in the clinic. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. The ascending temperature gradient measured in the central point of non-contacted surface was fastest, the average ascending temperature gradient of both moxaes was $0.0384^{\circ}C/sec$, $0.0123^{\circ}C/sec$ respectively, 3.1 times faster in LMA. The maximum ascending temperature gradient was also about 2.9 times faster in LMA. The time required for the maximum ascending temperature gradient from ignition was 254sec, 411sec respectively. 2. The minimum descending temperature gradient in the retaining period was $-0.0250^{\circ}C/sec$, $-0.0090^{\circ}C/sec$ respectively and the average descending temperature gradient was $-0.0160^{\circ}C/sec$, $-0.0037^{\circ}C/sec$ respectively on the non-contact surface. 3. On the basis of the non-contact surface($A_I$), the time at which the effective stimulus period began to occur was about 264sec, 796sec respectively after an ignition, the time at which the maximum temperature began to occur was about 373sec, 1323sec respectively after an ignition, and the maximum temperature was $0.9^{\circ}C$ higher in LMA. The maximum ascending temperature gradient was also about 4.2 times faster in LMA. Conclusion : It was thought that not only the figure of moxicombustion device, but also the form and size of moxa had influence on the combustion characteristics deciding the performance of stimulus seriously.

  • PDF