• 제목/요약/키워드: Neutron generator

검색결과 41건 처리시간 0.08초

A high-stability neutron generator for industrial online elemental analysis

  • Xiang-quan Chen;Lei Xiong;Hui Xie;Jing-fu Guo;Xue-ming Zhang;Yong-jun Dong
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1441-1453
    • /
    • 2024
  • The yield stability of the neutron generator directly affects the accuracy of elemental analysis. This paper presents an industrial fully automatic neutron generator with a 48 mm neutron tube based on PLC to improve the stability and reliability of the neutron generator in industrial applications. By integrating a Kalman Filter with the PID algorithm in a PLC, the neutron yield of the generator is remarkably stabilized, achieving 1 × 108n/s. The neutron generator has been employed for industrial online elemental analysis. The results demonstrate that only a slight fluctuation of ±0.82 % exists in the neutron yield, and the reproducibility of the generator holds at a significant level of 0.05. This improved neutron generator can be applied to the online bulk analysis of carbon in coal-fired power stations and absolute measurement of neutron source emission rate.

Occupational radiation exposure control analyses of 14 MeV neutron generator facility: A neutronic assessment for the biological and local shield design

  • Swami, H.L.;Vala, S.;Abhangi, M.;Kumar, Ratnesh;Danani, C.;Kumar, R.;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1784-1791
    • /
    • 2020
  • The 14 MeV neutron generator facility is being developed by the Institute for Plasma Research India to conduct the lab scale experiments related to Indian breeding blanket system for ITER and DEMO. It will also be utilized for material testing, shielding experiments and development of fusion diagnostics. Occupational radiation exposure control is necessary for the all kind of nuclear facilities to get the operational licensing from governing authorities and nuclear regulatory bodies. In the same way, the radiation exposure for the 14 MeV neutron generator facility at the occupational worker area and accessible zones for general workers should be under the permissible limit of AERB India. The generator is designed for the yield of 1012 n/s. The shielding assessment has been made to estimate the radiation dose during the operational time of the neutron generator. The facility has many utilities and constraints like ventilation ducts, accessible doors, accessibility of neutron generator components and to conduct the experiments which make the shielding assessment challenging to provide proper safety for occupational workers and the general public. The neutron and gamma dose rates have been estimated using the MCNP radiation transport code and ENDF -VII nuclear data libraries. The ICRP-74 fluence to dose conversion coefficients has been used for the assessment. The annual radiation exposure has been assessed by considering 500 h per year operational time. The provision of local shield near to neutron generator has been also evaluated to reduce the annual radiation doses. The comprehensive results of radiation shielding capability of neutron generator building and local shield design have been presented in the paper along with detailed maps of radiation field.

고속 고정밀 중성자 측정을 위한 하드웨어 설계에 관한 연구 (A Study On Hardware Design for High Speed High Precision Neutron Measurement)

  • 장경욱;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.61-67
    • /
    • 2016
  • 본 논문에서는 중성자 방사선 측정을 위한 고속 고정밀 중성자 측정을 위한 하드웨어 설계방법을 제안한다. 제안된 고속 고정밀 중성자 측정 장치의 하드웨어 설계는 고성능 A/D 변환기를 사용하여 고정밀 고속의 아날로그 신호를 디지털 데이터로 변환할 수 있도록 구성된다. 중성자 센서를 사용하여 입사된 중성자 방사선 입자를 검출하고, 극저전류 정밀 측정 모듈을 통해 검출된 중성자 방사선을 보다 정밀하고 빠르게 측정하는 모듈을 설계한다. 고속 고정밀 중성자 측정을 위한 하드웨어 시스템은 중성자 센서부, 가변 고전압 발생부, 극저전류 정밀 측정부, 임베디드 시스템부, 디스플레이부 등으로 구성 된다. 중성자 센서부는 고밀도 폴리에틸렌을 통해 중성자 방사선을 검출하는 기능을 수행한다. 가변 고전압 발생부는 중성자 센서가 정상적으로 운영되기 위하여 발열 및 잡음 특성에 강인한 0 ~ 2KV 가변 고전압 발생장치의 기능을 수행한다. 극저전류 정밀 측정부는 중성자 센서에서 출력되는 고정밀 고속의 극저전류 신호를 고성능 A/D 변환기를 사용하여 정밀하고 빠르게 측정하고 아날로그 신호를 디지털 신호로 변환하는 기능을 수행한다. 임베디드 시스템부는 고속 고정밀 중성자 측정을 위한 중성자 방사선 측정 기능, 가변 고전압 발생장치 제어 기능, 유무선 통신 제어 기능, 저장 기능 등을 수행한다. 제안된 고속 고정밀 중성자 측정을 위한 하드웨어를 실험한 결과, 불확도, 중성자 측정 속도, 정확도, 중성자 측정 범위 등에서 기존의 장치보다 우수한 성능이 나타남을 확인할 수가 있다.

MEASUREMENT OF THE D-D NEUTRON GENERATION RATE BY PROTON COUNTING

  • Kim, In-Jung;Jung, Nam-Suk;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.299-304
    • /
    • 2008
  • A detection system was set up to measure the neutron generation rate of a recently developed D-D neutron generator. The system is composed of a Si detector, He-3 detector, and electronics for pulse height analysis. The neutron generation rate was measured by counting protons using the Si detector, and the data was crosschecked by counting neutrons with the He-3 detector. The efficiencies of the Si and He-3 detectors were calibrated independently by using a standard alpha particle source $^{241}Am$ and a bare isotopic neutron source $^{252}Cf$, respectively. The effect of the cross-sectional difference between the D(d,p)T and $D(d,n)^3He$ reactions was evaluated for the case of a thick target. The neutron generation rate was theoretically corrected for the anisotropic emission of protons and neutrons in the D-D reactions. The attenuations of neutron on the path to the He-3 detector by the target assembly and vacuum flange of the neutron generator were considered by the Monte Carlo method using the MCNP 4C2 code. As a result, the neutron generation rate based on the Si detector measurement was determined with a relative uncertainty of ${\pm}5%$, and the two rates measured by both detectors corroborated within 20%.

Neutronic design of pulsed neutron facility (PNF) for PGNAA studies of biological samples

  • Oh, Kyuhak
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.262-268
    • /
    • 2022
  • This paper introduces a novel concept of the pulsed neutron facility (PNF) for maximizing the production of the thermal neutrons and its application to medical use based on prompt gamma neutron activation analysis (PGNAA) using Monte Carlo simulations. The PNF consists of a compact D-T neutron generator, a graphite pile, and a detection system using Cadmium telluride (CdTe) detector arrays. The configuration of fuel pins in the graphite monolith and the design and materials for the moderating layer were studied to optimize the thermal neutron yields. Biological samples - normal and cancerous breast tissues - including chlorine, a trace element, were used to investigate the sensitivity of the characteristic γ-rays by neutron-trace material interactions and the detector responses of multiple particles. Around 90 % of neutrons emitted from a deuterium-tritium (D-T) neutron generator thermalized as they passed through the graphite stockpile. The thermal neutrons captured the chlorines in the samples, then the characteristic γ-rays with specific energy levels of 6.12, 7.80 and 8.58 MeV were emitted. Since the concentration of chlorine in the cancerous tissue is twice that in the normal tissue, the count ratio of the characteristic g-rays of the cancerous tissue over the normal tissue is approximately 2.

DT 중성자 발생기에 의한 중성자 검출기 반응도 조사 (Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator)

  • 김상인;장인수;김장렬;이정일;김봉환
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.35-40
    • /
    • 2012
  • 국내 교정기관 또는 표준기관은 중성자 검출기의 교정을 위해 비감속 및 중수감속 $^{252}Cf$ 선원과 $^{241}AmBe$ 선원을 사용하고 있다. 이런 선원들로 교정된 중성자 검출기를 이용하여 입자가속기와 같이 속중성자가 다량 존재하는 시설을 선량평가할 때, 그 정확도가 떨어지게 된다. 그 이유는, 대부분의 중성자 검출기는 열중성자에 민감하게 반응하므로 수 MeV 이상의 에너지를 가지는 속중성자장에 대한 선량당량 반응도는 부정확하다. 또한 높은 에너지의 중성자는 열중성자보다 선량기여정도가 훨씬 크기 때문이다. 이와 같은 이유로, 기존의 교정용 기준 중성자장이 아닌 수 MeV 이상의 속중성자가 존재하는 중성자장에서도 검출기를 교정할 필요가 있다. DT 중성자 발생기, 흑연집합체 그리고 폴리에틸렌 중성자 집속체를 사용하여 속중성자의 선속분율이 서로 다른 중성자장을 제작하였고, 이 중성자장에서 중성자 검출기의 선량당량 반응도를 측정하였다. 시험결과에 의하면, 속중성자 선속분율과 중성자 검출기의 종류에 따라 중성자 검출기의 반응도는 많은 차이를 보였다. 이러한 반응도 차이는 선량당량의 과대 및 과소평가를 의미하므로, 검출기가 사용되는 시설환경과 유사한 중성자장에서 반응도 교정이 필요함을 확인하였다.

Neutron irradiation impact on structural and electrical properties of polycrystalline Al2O3

  • Sunil Kumar;Sejal Shah;S. Vala;M. Abhangi;A. Chakraborty
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.402-409
    • /
    • 2024
  • High energy neutron irradiations impact on structural and electrical properties of alumina are studied with particular emphasis on real time in-situ radiation induced conductivity measurement in low flux region. Polycrystalline Al2O3 samples are subjected to high energy neutrons produced from D-T neutron generator and Am-Be neutron source. 14 MeV neutrons from D-T generator are chosen to study the role of fast neutron irradiation in the structural modification of samples. Real time in-situ electrical measurement is performed to investigate the change in insulation resistance of Al2O3 due to radiation induced conductivity at low flux regime. During neutron irradiation, a significant transient decrease in insulation resistance is observed which recovers relative higher value just after neutron exposure is switched off. XRD results of 14 MeV neutron irradiated samples suggest annealing effect. Impact of relatively low energy neutrons on the structural properties is also studied using Am-Be neutrons. In this case, clustering is observed on the sample surface after prolonged neutron exposure. The structural characterizations of pristine and irradiated Al2O3 samples are performed using XRD, SEM, and EDX. The results from these characterizations are analysed and interpreted in the manuscript.

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

Development of a DDA+PGA-combined non-destructive active interrogation system in "Active-N"

  • Kazuyoshi Furutaka;Akira Ohzu;Yosuke Toh
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4002-4018
    • /
    • 2023
  • An integrated neutron interrogation system has been developed for non-destructive assay of highly-radioactive special nuclear materials, to accumulate knowledge of the method through developing and using it. The system combines a differential die-away (DDA) measurement system for the quantification of nuclear materials and a prompt gamma-ray analysis (PGA) system for the detection of neutron poisons which disturb the DDA measurements; a common D-T neutron generator is used. A special care has been taken for the selection of materials to reduce the background gamma rays produced by the interrogation neutrons. A series of measurements were performed to test the basic performance of the system. The results show that the DDA system can quantify plutonium of as small as 20 mg and it is not affected by intense neutron background up to 1.57 × 107 s-1 and gamma ray of 4.43 × 1010 s-1. The gamma-ray background counting rate at the PGA detector was reduced down to 3.9 × 103 s-1 even with the use of the D-T neutron generator. The test measurements show that the PGA system is capable of detecting 0.783 g of boron and about 86.8 g of gadolinium in 30 min.