• 제목/요약/키워드: Neutron dose rate

검색결과 62건 처리시간 0.024초

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

Neutron Dose Rate Analysis of PWR Spent Fuel Transport Cask Using Monte Carlo Method

  • Do, Mahnsuck;Kim, Jong-Kyung;Yoon, Jeong-Hyoun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.847-852
    • /
    • 1995
  • A shielding analysis for KSC-7, the shipping cask for transporting the 7 PWR spent fuel assemblies, has been carried out. Radiation source term has been calculated on spent fuel with burnup of 50,000 MWD/MTU and 1.5 years cooling time by ORIGEN2 code. The shielding calculation for the cask has been made by using MCNP4A code with continuous cross section data library from ENDF/B-V. As a result of neutron dose rate analysis, another shielding calculational model on spent fuel shipping cask was provided which is using the Monte Carlo method.

  • PDF

Monte Carlo shielding evaluation of a CSNS Multi-Physics instrument

  • Liang, Tairan;Shen, Fei;Yin, Wen;Xu, Juping;Yu, Quanzhi;Liang, Tianjiao
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1998-2004
    • /
    • 2019
  • The Multi-Physics (MP) instrument is one of 20 neutron spectrometers planned in the China Spallation Neutron Source (CSNS). This paper presents a shielding calculation for the MP instrument using Monte Carlo codes MCNPX and FLUKA. First, the neutrons that escape from the CSNS decoupled water moderator and are delivered to the beam line of the MP instrument are calculated to use as the source term of the shielding calculation. Then, to validate the calculation method based on multiple variance reduction techniques, a cross check between MCNPX and FLUKA codes is performed by comparing the calculation results of the dose rate distribution on a simplified beam line model. Finally, a complete geometry model of the MP instrument is set up, and the primary parameters for the shielding design are obtained according to the calculated dose rate map considering different worst-case scenarios.

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

Fabrication and Evaluation of Radiation Shielding Property of Epoxy Resin-Type Neutron Shielding Materials (에폭시수지계 중성자 차폐재의 제조 및 방사선 차폐능 평가)

  • Cho, Soo-Haeng;Yoon, Jeong-Hyoun;Choi, Byung-I1;Do, Jae-Bum;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • 제22권2호
    • /
    • pp.77-83
    • /
    • 1997
  • Epoxy resin-type neutron shielding materials, KNS(Kaeri Neutron Shield)-101, KNS-102, and KNS-103 have been fabricated to be used in spent fuel shipping cask. The base material is epoxy resin, and polypropylene, aluminium hydroxide, and boron carbide are added. These shielding materials offer good fluidity at processing, which makes it possible to apply this resin shield to complicated geometric shapes such as shipping cask. The shielding property of these shielding materials for shipping cask for loading 28 PWR spent fuel assemblies has been evaluated. ANISN code is used to evaluate the shielding property of the shipping cask with the thickness of the three neutron shielding materials greater than 10 cm. As a result of analysis, the maximum calculated dose rate at the radial surface of the cask is determined to be $300{\mu}Sv/h$ and the maximum calculated dose rate at 100 cm from the cask is $97{\mu}Sv/h$. These dose rates remain within allowable values specified in related regulations.

  • PDF

Measurement of neutron spectra in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector (LiI 섬광검출기 기반의 보너구 스펙트로메터를 이용한 MC50 사이클로트론의 중성자스펙트럼 측정)

  • Ha, Wi-Ho;Park, Seyoung;Yoo, Jaeryong;Yoon, Seokwon;Lee, Seung-Sook;Kim, Jungho;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • 제38권3호
    • /
    • pp.143-148
    • /
    • 2013
  • Operational nuclear facilities such as nuclear power plants and particle accelerators show various neutron spectra according to the type of facilities and specific position. Necessities of neutron dose management and neutron monitoring for radiation protection of radiation workers in such a kind of facilities have continuously increased in recent years. Bonner sphere spectrometers are widely used for measurement of neutron spectra. Data on response function of neutron detector, default neutron spectra and count rates of Bonner sphere spectrometer are required to obtain unfolded neutron spectra in specific workplaces. In this study, we carried out measurement of neutron spectra produced in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector. Additionally, we estimated quantitative data on neutron flux, mean neutron energy and ambient dose equivalent rate according to the incident proton energies and positions in MC50 cyclotron.

The Effects of Korean Ginseng Components for the Mouse Irradiated 1 by Neutron(Besource) (중성자방사선에 피폭된 생쥐에 대한 인삼제제의 효과에 관하여)

  • 공태희;유성열
    • Journal of Ginseng Research
    • /
    • 제14권3호
    • /
    • pp.357-363
    • /
    • 1990
  • When mice irradiated by neutron (Be) are fed with ginseng concentrate, ginseng powder, and adaptagen of which the major ingredient is ginseng alkaloid to neutron (Be source) irradiated mouse, the following results are obtained. 1. The 50% lethal dose (LD50) for the neutron irradiation were 4 days at 600 rad, 7 days at 500 rad, 16 days at 400 rad, 33 days at 375 rad, and 55 days at 350 rad. In thistest, the standard amollntofirradiation was set at 375 rad/8 min. 2. Some spots appeared in the tail of the neutron-irradiated mouse because of blood congestion, and some had its tip tails cut. But the group administered with adaptagen did not show any of these symptoms. 3. The neutron irradiated mouse showed darkening the color of their lung-chloasmas while none of the adaptagen group had this symptom. 4. The lung tissue of the neutron irradiated mouse showed an increase of the karyolysis and cytoplasmic vacuole. 5. When both neutron irradiation and the ginseng sllbstances were given to the mouse at the same day, the 50% lethal days were increased to 29-33 days for the group administered with ginseng extract. 67 days for the group given with the ginseng powder. and 80 days for the groilp arith the adaptagen. 6. The survival rate of those fed with adaptagen for 33 days before the neutron-irradiation was 100%, while the 50% lethal daysofthe group fed with ginsengextract were 39 days and that of the group fed with ginseng powder were 69 days. 7. The serum valued of ${\gamma}$-globulin, IgG, and albumin were returned to normal condition in the group fed with adaptagen for 33 days before the neutron-irradiation. But those of the group which were given the irradiation and the ginseng substances at the same day did not show such a recovery.

  • PDF

A Study on the Evaluation of Surface Dose Rate of New Disposal Containers Though the Activation Evaluation of Bio-Shield Concrete Waste From Kori Unit 1

  • Kang, Gi-Woong;Kim, Rin-Ah;Do, Ho-Seok;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제19권1호
    • /
    • pp.133-140
    • /
    • 2021
  • This study evaluates the radioactivity of concrete waste that occurs due to large amounts of decommissioned nuclear wastes and then determines the surface dose rate when the waste is packaged in a disposal container. The radiation assessment was conducted under the presumption that impurities included in the bio-shielded concrete contain the highest amount of radioactivity among all the concrete wastes. Neutron flux was applied using the simplified model approach in a sample containing the most Co and Eu impurities, and a maximum of 9.8×104 Bq·g-1 60Co and 2.63×105 Bq·g-1 152Eu was determined. Subsequently, the surface dose rate of the container was measured assuming that the bio-shield concrete waste would be packaged in a newly developed disposal container. Results showed that most of the concrete wastes with a depth of 20 cm or higher from the concrete surface was found to have less than 1.8 mSv·hr-1 in the surface dose of the new-type disposal container. Hence, when bio-shielded concrete wastes, having the highest radioactivity, is disposed in the new disposal container, it satisfies the limit of the surface dose rate (i.e., 2 mSv·hr-1) as per global standards.

Comparing the performance of two hybrid deterministic/Monte Carlo transport codes in shielding calculations of a spent fuel storage cask

  • Lai, Po-Chen;Huang, Yu-Shiang;Sheu, Rong-Jiun
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.2018-2025
    • /
    • 2019
  • This study systematically compared two hybrid deterministic/Monte Carlo transport codes, ADVANTG/MCNP and MAVRIC, in solving a difficult shielding problem for a real-world spent fuel storage cask. Both hybrid codes were developed based on the consistent adjoint driven importance sampling (CADIS) methodology but with different implementations. The dose rate distributions on the cask surface were of primary interest and their predicted results were compared with each other and with a straightforward MCNP calculation as a baseline case. Forward-Weighted CADIS was applied for optimization toward uniform statistical uncertainties for all tallies on the cask surface. Both ADVANTG/MCNP and MAVRIC achieved substantial improvements in overall computational efficiencies, especially for gamma-ray transport. Compared with the continuous-energy ADVANTG/MCNP calculations, the coarse-group MAVRIC calculations underestimated the neutron dose rates on the cask's side surface by an approximate factor of two and slightly overestimated the dose rates on the cask's top and side surfaces for fuel gamma and hardware gamma sources because of the impact of multigroup approximation. The fine-group MAVRIC calculations improved to a certain extent and the addition of continuous-energy treatment to the Monte Carlo code in the latest MAVRIC sequence greatly reduced these discrepancies. For the two continuous-energy calculations of ADVANTG/MCNP and MAVRIC, a remaining difference of approximately 30% between the neutron dose rates on the cask's side surface resulted from inconsistent use of thermal scattering treatment of hydrogen in concrete.

VARIATION OF NEUTRON MODERATING POWER ON HDPE BY GAMMA RADIATION

  • Park, Kwang-June;Ju, June-Sik;Kang, Hee-Young;Shin, Hee-Sung;Kim, Ho-Dong
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.9-14
    • /
    • 2009
  • High density polyethylene (HDPE) is degraded due to a radiation-induced oxidation when it is used as a neutron moderator in a neutron counter for a nuclear material accounting of spent fuels. The HDPE exposed to the gamma-ray emitted from the fission products in a spent nuclear fuel results in a radiation-induced degradation which changes its original molecular structure to others. So a neutron moderating power variation of HDPE, irradiated by a gamma radiation, was investigated in this work. Five HDPE moderator structures were exposed to the gamma radiation emitted from a $^{60}Co$ source to a level of $10^5-10^9$ rad to compare their post-irradiation properties. As a result of the neutron measurement test with 5 irradiated HDPE structures and a neutron measuring system, it was confirmed that the neutron moderating power for the $10^5$ rad irradiated HDPE moderator revealed the largest decrease when the un-irradiated pure one was used as a reference. It implies that a neutron moderating power variation of HDPE is not directly proportional to the integrated gamma dose rate. To clarify the cause of these changes, some techniques such as a FTIR, an element analysis and a densitometry were employed. As a result of these analyses, it was confirmed that the molecular structure of the gamma irradiated HDPEs had partially changed to others, and the contents of hydrogen and oxygen had varied during the process of a radiation-induced degradation. The mechanism of these changes cannot be explained in detail at present, and thus need further study.