• Title/Summary/Keyword: Neutron Activation Analysis

Search Result 185, Processing Time 0.051 seconds

Determination of Impurities in Aluminum by Neutron Activation Analysis

  • Kim, Nak-Bae;Bak, Hae-ill;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.29-38
    • /
    • 1980
  • A radiochemical separation scheme for the neutron activation analysis is developed for the determination of 28 elements in aluminum. The scheme is based on a group separation using ion-exchange resin and mineral exchanger. Present work has employed mineral acids and their partly organic mixture excluding HF as the media as well as common glass wares. For the determination, gamma-ray spectroscopy using $3"\times3"\;Nal(TI)$ detector and a single comparator method are used.

  • PDF

Determination of Impurities in Uranium Dioxide by Neutron Activation Analysis (중성자방사화분석법에 의한 이산화우라늄중의 불순물정량)

  • Nak Bae Kim;Hae-Ill Bak;Chul Lee
    • Nuclear Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.237-244
    • /
    • 1981
  • The preliminary concentration of trace elements in uranium dioxide using an anion exchange resin is presented for neutron activation analysis. The uranyl solution in sulfuric acid is adjusted to the acidity of about pH 2.7 and loaded on a column of the anion exchange resin. An appropriate volume of eluates obtained from the column shows good recoveries of trace elements. By combining this preconcentration with a radiochemical separation scheme, which was developed for the determinations of impurities in aluminum, it is possible to determine 21 trace elements in reactor grade uranium dioxide.

  • PDF

A STUDY ON KOREAN ANTHRACITE BY INSTRUMENTAL NEUTRON ACTIVATION ANALYSIS

  • Kim, N.B.;Woo, H.J.;Lee, K.Y.;Hong, W.;Chun, S.K.;Park, K.S.
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.477-482
    • /
    • 1994
  • By the instrumental neutron activation analysis using two comparators of gold and cobalt, 31 elements have been anlalyzed in anthracites collected from two main coal-fields in Korea. The average concentrations and ranges of the elements were obtained with the elemental difference between two coal-fields. The trends of rare-earth elemental distribution and vertical elemental distribution are also given.

  • PDF

Origin of Spherule Samples Recovered from Antarctic Ice Sheet-Terrestrial or Extraterrestrial?

  • Sekimoto, Shun;Kobayashi, Takayuki;Takamiya, Koichi;Ebihara, Mitsuru;Shibata, Seiichi
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.293-298
    • /
    • 2016
  • Thirty-eight spherules from the Antarctic ice sheet were analyzed using neutron activation analysis under two different conditions to investigate their origin. In almost all of these spherules, the contents of iron, cobalt, and manganese were determined to be 31% to 88%, 17 mg/kg to 810 mg/kg, and 0.017% to 7%, respectively. A detectable iridium content of 0.84 mg/kg was found in only one spherule, which was judged to be extraterrestrial in origin. A comparison of elemental compositions of the Antarctic spherules analyzed in this study with those of deep-sea sediment spherules and those of terrestrial materials revealed that most of the Antarctic spherules except for the sample in which iridium was detected could not be identified as extraterrestrial in origin.

A Study on the Present Levels of Mercury and other Trace Elements in Fresh-water Fish by Neutron Activation Analysis

  • Kim, Nak-Bae;Lee, Chul;Bak, Hae-Ill
    • Nuclear Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.41-47
    • /
    • 1976
  • A nondestructive, instrumental neutron activation analysis using a Ge(Li) detector is applied to investigate the present levels of mercury and other trace elements in some fresh-water fish. The results show large variations of mercury content which are indicative of important local sources and indicate the inter-dependence relations between two of some trace elements. Analytical results for mercury in antracites are also given with the concern for their combustion as one of major causes of the mercury pollution.

  • PDF

Determination of Trace Impurities in High Purity Aluminum by Instrumental Neutron Activation Analysis (고순도알루미늄의 비파괴 중성자방사화분석)

  • Cho, Seung-Yeon;Kim, Young-Kuk;Chung, Yong-Sam
    • Nuclear Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.163-167
    • /
    • 1992
  • Nondestructive neutron activation analysis of copper in high purity Aluminum samples which can be used as a parameter of impurity is investigated and determined. Other 23 trace impurity elements in the samples are also determined. In the analysis of copper, the new irradiation method using thermal column was applied to reduce the interfering activity of 24Na produced by 27Al(n,$\alpha$)24Na reaction induced by fast neutron. As a result, the interference can be reduced to 100 times more than other activation methods. Also the influence by activity of 24Na is found in the range of 2~3 %. It has been observed that the copper contents in so-ratted“six nine”class standard aluminum samples are about 0.54 $\pm$ 0.08 ppm. By the comparison with other values re-ported, our results are reasonable and can be available as a improved routine analysis.

  • PDF

Determination of trace actinide (Am, Pu, Th, U) using alpha spectrometry and neutron activation analysis (알파분광법과 중성자방사화분석법에 의한 극미량의 악티늄계원소 (Am, Pu, Th, U)분석연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Kim, Yongjai;Lee, Myong Ho
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2004
  • Determination of actinides in the environmental sample requires separation of each element. This procedure is tedious and time consuming. And also, the detection limits of some nuclides using alpha spectrometry are rather higher. To overcome the lower detection limit and complicated separation procedure, a simple analytical technique for the determination of actinide isotopes in the environmental samples was developed and applied to IAEA and NIST reference sediment samples. For the separation of actinides from matrix, anion exchange resin and TRU-spec extraction chromatography resin were used and chemical yields were obtained using natural uranium, thorium, $^{242}Pu$ and $^{243}Am$ tracers. For overcoming the higher detection limits of U and Th in alpha spectrometry, neutron activation analysis was applied. Using combined method, the detection limit was increased about 10 times. The activity values of each isotope were consistent with the reference values reported by IAEA and NIST.

Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement - (중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 -)

  • Song, Byung Chul;Park, Yong Joon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.1041-1051
    • /
    • 2003
  • Neutron induced prompt gamma activation analysis (PGAA) offers a nondestructive, sensitive and relatively rapid method for the determination of trace and major elements and is proven to be convenient for online analysis of minerals, metals, coal, cement, petrochemical, coating, paper as well as many other materials and products. The technique has found many uses in medicine, industry, research, security and the detection of contraband items. This report reviews the present status and future trends of the PGAA techniques. Requirements for the system are neutron source, high resolution HPGe detectors with a high-voltage power supply, an amplifier, analog-to-digital converter, and a multichannel analyzer for the detection and measurement of prompt ${\gamma}$-ray emit form the neutron capture elements. Introducing a ${\gamma}$-${\gamma}$ coincidence system also improves the quality of the ${\gamma}$-ray spectrum by suppressing the background created from the Compton scattering of high energy prompt ${\gamma}$-rays. A PGAA system using a $^{252}Cf$ neutron source is currently under construction for the on-line measurement of several elements in aqueous samples at KAERI. The system can be applied for the detection of chemical weapons and explosives as well as various narcotics.